Salvage of Cardiac Implantable Electronic Device Pocket Infection with Skin Erosion in Frail 92-Year-Old

We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely interna...

Full description

Saved in:
Bibliographic Details
Published in:Journal of cardiovascular development and disease 2022-03, Vol.9 (3), p.81
Main Authors: Giaccardi, Marzia, Baldauf, Benito, Lau, Ernest W, Borov, Stefan, Bonnemeier, Hendrik
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We reported the novel use of a taurolidine-containing antimicrobial solution in the successful salvage of a partially exposed and polymicrobially infected cardiac implantable electronic device pulse generator in a frail patient unfit for lead extraction. The old, salvaged device was entirely internalized, and there were no signs of recurrent infection at 9 months follow-up.
ISSN:2308-3425
2308-3425
DOI:10.3390/jcdd9030081