Loading…
Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report
Nickel and cobalt are frequently found in metallic alloys used in the manufacture of aneurysm clips and endovascular prostheses, such as the pipeline embolization device (PED). Nickel hypersensitivity can affect up to 15% of the population, however, it is very rarely overt in patients who undergo en...
Saved in:
Published in: | Brain circulation 2024-01, Vol.10 (1), p.85-88 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c457t-ee9dd87d5b72e64ebaae54d711570565678fc1d66eac91a88d0dbf2a62044a033 |
container_end_page | 88 |
container_issue | 1 |
container_start_page | 85 |
container_title | Brain circulation |
container_volume | 10 |
creator | Martio, Artur Eduardo Kieling, Daniel Marchi Manzato, Luciano Bambini Vanzin, José Ricardo |
description | Nickel and cobalt are frequently found in metallic alloys used in the manufacture of aneurysm clips and endovascular prostheses, such as the pipeline embolization device (PED). Nickel hypersensitivity can affect up to 15% of the population, however, it is very rarely overt in patients who undergo endovascular stent placement. Here, we present the case of a 35-year-old woman who developed allergic symptoms after PED placement and was later confirmed to be allergic to both nickel and cobalt by patch testing. Fortunately, she responded well to pharmacologic treatment, rendering surgical intervention unnecessary. To the best of our knowledge, this is the first report of symptomatic nickel hypersensitivity, and the second report of symptomatic cobalt allergy caused by the PED. Despite its low prevalence, we believe that surgeons should actively inquire patients in the postoperative period about allergic symptoms, to facilitate early diagnosis and treatment. |
doi_str_mv | 10.4103/bc.bc_85_23 |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_0bfbfdf86f1042459a1dba03ca61a3ad</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A790160150</galeid><doaj_id>oai_doaj_org_article_0bfbfdf86f1042459a1dba03ca61a3ad</doaj_id><sourcerecordid>A790160150</sourcerecordid><originalsourceid>FETCH-LOGICAL-c457t-ee9dd87d5b72e64ebaae54d711570565678fc1d66eac91a88d0dbf2a62044a033</originalsourceid><addsrcrecordid>eNp9kk1r3DAQhk1paUKaU-9FUOileCtZX3YvZQn9CARyac9iLI13tbUtV_IubH59td0kzUIpOkjMPPNKemeK4jWjC8Eo_9DaRWtNLU3FnxXnlZCyFKpSz_OZN6KsGa3PisuUNpRSpmsutXpZnPFaSSm4Pi_c7Q7jTEZvf2JPYHTEhhb6maz3E8aEY_Kz3_l5T6CbMZLJT9j7EQkObej9Hcw-jMThzlskUw8WBxznj2RJLCQkEacQ51fFiw76hJf3-0Xx48vn71ffypvbr9dXy5vSCqnnErFxrtZOtrpCJbAFQCmcZkxqKpVUuu4sc0oh2IZBXTvq2q4CVVEhgHJ-UVwfdV2AjZmiHyDuTQBv_gRCXBmIs7c9Gtp2bee6WnWMimxbA8y1WcOCYsDBZa1PR61p2w7obP5VhP5E9DQz-rVZhZ1huS1CCJYV3t4rxPBri2k2m7CNYzbAcJbzdVUp9V-K8oYKzTX9S60gP96PXch32sEna5a6oUxRJg_U4h9UXg4Hb8OInc_xk4J3TwrWmBu_TqHfHpqaTsH3R9DGkFLE7tEIRs1hEE2ewodBzPSbp949sg9jx38DYwbYrg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3039047370</pqid></control><display><type>article</type><title>Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>PubMed Central</source><creator>Martio, Artur Eduardo ; Kieling, Daniel Marchi ; Manzato, Luciano Bambini ; Vanzin, José Ricardo</creator><creatorcontrib>Martio, Artur Eduardo ; Kieling, Daniel Marchi ; Manzato, Luciano Bambini ; Vanzin, José Ricardo</creatorcontrib><description>Nickel and cobalt are frequently found in metallic alloys used in the manufacture of aneurysm clips and endovascular prostheses, such as the pipeline embolization device (PED). Nickel hypersensitivity can affect up to 15% of the population, however, it is very rarely overt in patients who undergo endovascular stent placement. Here, we present the case of a 35-year-old woman who developed allergic symptoms after PED placement and was later confirmed to be allergic to both nickel and cobalt by patch testing. Fortunately, she responded well to pharmacologic treatment, rendering surgical intervention unnecessary. To the best of our knowledge, this is the first report of symptomatic nickel hypersensitivity, and the second report of symptomatic cobalt allergy caused by the PED. Despite its low prevalence, we believe that surgeons should actively inquire patients in the postoperative period about allergic symptoms, to facilitate early diagnosis and treatment.</description><identifier>ISSN: 2394-8108</identifier><identifier>EISSN: 2455-4626</identifier><identifier>DOI: 10.4103/bc.bc_85_23</identifier><identifier>PMID: 38655437</identifier><language>eng</language><publisher>India: Medknow Publications and Media Pvt. Ltd</publisher><subject>Alloys ; Aneurysms ; Case Report ; Cobalt ; endovascular aneurysm repair ; hypersensitivity ; Nickel ; pipeline embolization device ; Stent (Surgery)</subject><ispartof>Brain circulation, 2024-01, Vol.10 (1), p.85-88</ispartof><rights>Copyright: © 2024 Brain Circulation.</rights><rights>COPYRIGHT 2024 Medknow Publications and Media Pvt. Ltd.</rights><rights>2024. This article is published under (http://creativecommons.org/licenses/by-nc-sa/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Copyright: © 2024 Brain Circulation 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c457t-ee9dd87d5b72e64ebaae54d711570565678fc1d66eac91a88d0dbf2a62044a033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11034441/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/3039047370?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25752,27923,27924,37011,44589,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/38655437$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Martio, Artur Eduardo</creatorcontrib><creatorcontrib>Kieling, Daniel Marchi</creatorcontrib><creatorcontrib>Manzato, Luciano Bambini</creatorcontrib><creatorcontrib>Vanzin, José Ricardo</creatorcontrib><title>Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report</title><title>Brain circulation</title><addtitle>Brain Circ</addtitle><description>Nickel and cobalt are frequently found in metallic alloys used in the manufacture of aneurysm clips and endovascular prostheses, such as the pipeline embolization device (PED). Nickel hypersensitivity can affect up to 15% of the population, however, it is very rarely overt in patients who undergo endovascular stent placement. Here, we present the case of a 35-year-old woman who developed allergic symptoms after PED placement and was later confirmed to be allergic to both nickel and cobalt by patch testing. Fortunately, she responded well to pharmacologic treatment, rendering surgical intervention unnecessary. To the best of our knowledge, this is the first report of symptomatic nickel hypersensitivity, and the second report of symptomatic cobalt allergy caused by the PED. Despite its low prevalence, we believe that surgeons should actively inquire patients in the postoperative period about allergic symptoms, to facilitate early diagnosis and treatment.</description><subject>Alloys</subject><subject>Aneurysms</subject><subject>Case Report</subject><subject>Cobalt</subject><subject>endovascular aneurysm repair</subject><subject>hypersensitivity</subject><subject>Nickel</subject><subject>pipeline embolization device</subject><subject>Stent (Surgery)</subject><issn>2394-8108</issn><issn>2455-4626</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNp9kk1r3DAQhk1paUKaU-9FUOileCtZX3YvZQn9CARyac9iLI13tbUtV_IubH59td0kzUIpOkjMPPNKemeK4jWjC8Eo_9DaRWtNLU3FnxXnlZCyFKpSz_OZN6KsGa3PisuUNpRSpmsutXpZnPFaSSm4Pi_c7Q7jTEZvf2JPYHTEhhb6maz3E8aEY_Kz3_l5T6CbMZLJT9j7EQkObej9Hcw-jMThzlskUw8WBxznj2RJLCQkEacQ51fFiw76hJf3-0Xx48vn71ffypvbr9dXy5vSCqnnErFxrtZOtrpCJbAFQCmcZkxqKpVUuu4sc0oh2IZBXTvq2q4CVVEhgHJ-UVwfdV2AjZmiHyDuTQBv_gRCXBmIs7c9Gtp2bee6WnWMimxbA8y1WcOCYsDBZa1PR61p2w7obP5VhP5E9DQz-rVZhZ1huS1CCJYV3t4rxPBri2k2m7CNYzbAcJbzdVUp9V-K8oYKzTX9S60gP96PXch32sEna5a6oUxRJg_U4h9UXg4Hb8OInc_xk4J3TwrWmBu_TqHfHpqaTsH3R9DGkFLE7tEIRs1hEE2ewodBzPSbp949sg9jx38DYwbYrg</recordid><startdate>20240101</startdate><enddate>20240101</enddate><creator>Martio, Artur Eduardo</creator><creator>Kieling, Daniel Marchi</creator><creator>Manzato, Luciano Bambini</creator><creator>Vanzin, José Ricardo</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><general>Wolters Kluwer - Medknow</general><general>Wolters Kluwer Medknow Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20240101</creationdate><title>Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report</title><author>Martio, Artur Eduardo ; Kieling, Daniel Marchi ; Manzato, Luciano Bambini ; Vanzin, José Ricardo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c457t-ee9dd87d5b72e64ebaae54d711570565678fc1d66eac91a88d0dbf2a62044a033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Alloys</topic><topic>Aneurysms</topic><topic>Case Report</topic><topic>Cobalt</topic><topic>endovascular aneurysm repair</topic><topic>hypersensitivity</topic><topic>Nickel</topic><topic>pipeline embolization device</topic><topic>Stent (Surgery)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Martio, Artur Eduardo</creatorcontrib><creatorcontrib>Kieling, Daniel Marchi</creatorcontrib><creatorcontrib>Manzato, Luciano Bambini</creatorcontrib><creatorcontrib>Vanzin, José Ricardo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Brain circulation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Martio, Artur Eduardo</au><au>Kieling, Daniel Marchi</au><au>Manzato, Luciano Bambini</au><au>Vanzin, José Ricardo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report</atitle><jtitle>Brain circulation</jtitle><addtitle>Brain Circ</addtitle><date>2024-01-01</date><risdate>2024</risdate><volume>10</volume><issue>1</issue><spage>85</spage><epage>88</epage><pages>85-88</pages><issn>2394-8108</issn><eissn>2455-4626</eissn><abstract>Nickel and cobalt are frequently found in metallic alloys used in the manufacture of aneurysm clips and endovascular prostheses, such as the pipeline embolization device (PED). Nickel hypersensitivity can affect up to 15% of the population, however, it is very rarely overt in patients who undergo endovascular stent placement. Here, we present the case of a 35-year-old woman who developed allergic symptoms after PED placement and was later confirmed to be allergic to both nickel and cobalt by patch testing. Fortunately, she responded well to pharmacologic treatment, rendering surgical intervention unnecessary. To the best of our knowledge, this is the first report of symptomatic nickel hypersensitivity, and the second report of symptomatic cobalt allergy caused by the PED. Despite its low prevalence, we believe that surgeons should actively inquire patients in the postoperative period about allergic symptoms, to facilitate early diagnosis and treatment.</abstract><cop>India</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><pmid>38655437</pmid><doi>10.4103/bc.bc_85_23</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2394-8108 |
ispartof | Brain circulation, 2024-01, Vol.10 (1), p.85-88 |
issn | 2394-8108 2455-4626 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_0bfbfdf86f1042459a1dba03ca61a3ad |
source | Publicly Available Content Database (Proquest) (PQ_SDU_P3); PubMed Central |
subjects | Alloys Aneurysms Case Report Cobalt endovascular aneurysm repair hypersensitivity Nickel pipeline embolization device Stent (Surgery) |
title | Overt nickel and cobalt hypersensitivity after pipeline embolization device placement: A case report |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T10%3A18%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Overt%20nickel%20and%20cobalt%20hypersensitivity%20after%20pipeline%20embolization%20device%20placement:%20A%20case%20report&rft.jtitle=Brain%20circulation&rft.au=Martio,%20Artur%20Eduardo&rft.date=2024-01-01&rft.volume=10&rft.issue=1&rft.spage=85&rft.epage=88&rft.pages=85-88&rft.issn=2394-8108&rft.eissn=2455-4626&rft_id=info:doi/10.4103/bc.bc_85_23&rft_dat=%3Cgale_doaj_%3EA790160150%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c457t-ee9dd87d5b72e64ebaae54d711570565678fc1d66eac91a88d0dbf2a62044a033%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3039047370&rft_id=info:pmid/38655437&rft_galeid=A790160150&rfr_iscdi=true |