Loading…
Assessment of experimental OpenCV tracking algorithms for ultrasound videos
This study aims to compare the tracking algorithms provided by the OpenCV library to use on ultrasound video. Despite the widespread application of this computer vision library, few works describe the attempts to use it to track the movement of liver tumors on ultrasound video. Movements of the neop...
Saved in:
Published in: | Scientific reports 2023-04, Vol.13 (1), p.6765-6765, Article 6765 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study aims to compare the tracking algorithms provided by the OpenCV library to use on ultrasound video. Despite the widespread application of this computer vision library, few works describe the attempts to use it to track the movement of liver tumors on ultrasound video. Movements of the neoplasms caused by the patient`s breath interfere with the positioning of the instruments during the process of biopsy and radio-frequency ablation. The main hypothesis of the experiment was that tracking neoplasms and correcting the position of the manipulator in case of using robotic-assisted surgery will allow positioning the instruments more precisely. Another goal of the experiment was to check if it is possible to ensure real-time tracking with at least 25 processed frames per second for standard definition video. OpenCV version 4.5.0 was used with 7 tracking algorithms from the extra modules package. They are: Boosting, CSRT, KCF, MedianFlow, MIL, MOSSE, TLD. More than 5600 frames of standard definition were processed during the experiment. Analysis of the results shows that two algorithms—CSRT and KCF—could solve the problem of tumor tracking. They lead the test with 70% and more of Intersection over Union and more than 85% successful searches. They could also be used in real-time processing with an average processing speed of up to frames per second in CSRT and 100 + frames per second for KCF. Tracking results reach the average deviation between centers of neoplasms to 2 mm and maximum deviation less than 5 mm. This experiment also shows that no frames made CSRT and KCF algorithms fail simultaneously. So, the hypothesis for future work is combining these algorithms to work together, with one of them—CSRT—as support for the KCF tracker on the rarely failed frames. |
---|---|
ISSN: | 2045-2322 2045-2322 |
DOI: | 10.1038/s41598-023-30930-3 |