Endoscopic Reconstruction of Skull Base Defects Using Tutoplast
Background Various graft materials that are classified as autografts, xenografts, and allografts based on their origin have been used to endoscopically repair skull base defects. Tutoplast® (Tutogen Medical GmbH), an allogeneic natural collagen matrix, is processed through chemical sterilization tha...
Saved in:
Published in: | Allergy & rhinology (Providence, R.I.) R.I.), 2021-01, Vol.12, p.21526567211009200 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03 |
---|---|
cites | cdi_FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03 |
container_end_page | |
container_issue | |
container_start_page | 21526567211009200 |
container_title | Allergy & rhinology (Providence, R.I.) |
container_volume | 12 |
creator | Alokby, Ghassan AlAmari, Kholoud Mohammed Abdullah, Jamal Mohammed S. Tayed Hazazi, Mohammed Makki, Fawaz |
description | Background
Various graft materials that are classified as autografts, xenografts, and allografts based on their origin have been used to endoscopically repair skull base defects. Tutoplast® (Tutogen Medical GmbH), an allogeneic natural collagen matrix, is processed through chemical sterilization that preserves tissue biocompatibility and structural integrity.
Objective
To study the safety and efficacy of Tutoplast Fascia Lata and Tutoplast Temporalis Fascia® as primary graft materials in the endoscopic reconstruction of skull base defects of different sizes and etiologies and to compare the outcomes with those of other traditional graft materials based on our experience.
Methods
This is a multi-center retrospective chart review of patients who underwent cerebrospinal fluid leak (CSF) endoscopic reconstruction with Tutoplast Fascia Lata or Tutoplast Temporalis Fascia as either a stand-alone reconstruction material or a part of a multilayer reconstruction depending on the defect at Prince Sultan Military Medical City and King Faisal Specialist Hospital and Research Center in Riyadh, Saudi Arabia, between 2017 and 2020. Our inclusion criteria were CSF leak repair with Tutoplast and a transnasal endoscopic approach. We reviewed demographic data, intraoperative and postoperative complications, repair materials, repair failure, defect size and location.
Results
Tutoplast® was used as the primary graft material in 33 cases. Our main outcome was repair success with lack of post operative CSF leak, observed in 30 cases (90.9%). There was no significant association between postoperative CSF leaks and factors including different defect sizes, defect sites, demographic data, hospitalization duration, or postoperative radiation in oncological cases.
Conclusion
Tutoplast alone or in combination with other materials can be used safely and effectively for skull base defects repair. |
doi_str_mv | 10.1177/21526567211009200 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_0e5cbf1a332b42a9aa2c007f05d11c04</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_21526567211009200</sage_id><doaj_id>oai_doaj_org_article_0e5cbf1a332b42a9aa2c007f05d11c04</doaj_id><sourcerecordid>2613228387</sourcerecordid><originalsourceid>FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03</originalsourceid><addsrcrecordid>eNp1kV9rFTEQxYMottR-AF9kwedbJ_-TF0Vr1UJB0PY5ZCfJda_bzTXJFvz27vXW2iLOS4aTM79JOIQ8p3BCqdavGJVMSaUZpQCWATwihztttRMf3-sPyHGtG1iKW601fUoOODfGCi4PyZuzKeSKeTtg9yVinmorM7YhT11O3dfv8zh273yN3fuYIrbaXdVhWneXc8vb0df2jDxJfqzx-PY8Ilcfzi5PP60uPn88P317sUKhWFuZHrUxKiQbaVBUG0zUUkGFSN5iChFQYpCASnOlRQTPQrBoZVDa9wH4ETnfc0P2G7ctw7UvP132g_st5LJ2vrQBx-ggSuwT9ZyzXjBvvWcIoBPIQCmCWFiv96zt3F_HgHFqxY8PoA9vpuGbW-cbZ0CAlHwBvLwFlPxjjrW5TZ7LtPzfMUU5Y4Ybvbjo3oUl11piuttAwe0idP9EuMy8uP-0u4k_gS2Gk72h-nX8u_b_xF9g-6Nv</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2613228387</pqid></control><display><type>article</type><title>Endoscopic Reconstruction of Skull Base Defects Using Tutoplast</title><source>SAGE Open Access</source><source>Publicly Available Content Database</source><source>PubMed Central</source><creator>Alokby, Ghassan ; AlAmari, Kholoud Mohammed ; Abdullah, Jamal Mohammed S. ; Tayed Hazazi, Mohammed ; Makki, Fawaz</creator><creatorcontrib>Alokby, Ghassan ; AlAmari, Kholoud Mohammed ; Abdullah, Jamal Mohammed S. ; Tayed Hazazi, Mohammed ; Makki, Fawaz</creatorcontrib><description>Background
Various graft materials that are classified as autografts, xenografts, and allografts based on their origin have been used to endoscopically repair skull base defects. Tutoplast® (Tutogen Medical GmbH), an allogeneic natural collagen matrix, is processed through chemical sterilization that preserves tissue biocompatibility and structural integrity.
Objective
To study the safety and efficacy of Tutoplast Fascia Lata and Tutoplast Temporalis Fascia® as primary graft materials in the endoscopic reconstruction of skull base defects of different sizes and etiologies and to compare the outcomes with those of other traditional graft materials based on our experience.
Methods
This is a multi-center retrospective chart review of patients who underwent cerebrospinal fluid leak (CSF) endoscopic reconstruction with Tutoplast Fascia Lata or Tutoplast Temporalis Fascia as either a stand-alone reconstruction material or a part of a multilayer reconstruction depending on the defect at Prince Sultan Military Medical City and King Faisal Specialist Hospital and Research Center in Riyadh, Saudi Arabia, between 2017 and 2020. Our inclusion criteria were CSF leak repair with Tutoplast and a transnasal endoscopic approach. We reviewed demographic data, intraoperative and postoperative complications, repair materials, repair failure, defect size and location.
Results
Tutoplast® was used as the primary graft material in 33 cases. Our main outcome was repair success with lack of post operative CSF leak, observed in 30 cases (90.9%). There was no significant association between postoperative CSF leaks and factors including different defect sizes, defect sites, demographic data, hospitalization duration, or postoperative radiation in oncological cases.
Conclusion
Tutoplast alone or in combination with other materials can be used safely and effectively for skull base defects repair.</description><identifier>ISSN: 2152-6567</identifier><identifier>ISSN: 2152-6575</identifier><identifier>EISSN: 2152-6567</identifier><identifier>DOI: 10.1177/21526567211009200</identifier><identifier>PMID: 33889435</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Allografts ; Autografts ; Biocompatibility ; Cerebrospinal fluid ; Collagen ; Complications ; Defects ; Endoscopy ; Fascia ; Original ; Postoperative ; Skull ; Sterilization ; Xenografts</subject><ispartof>Allergy & rhinology (Providence, R.I.), 2021-01, Vol.12, p.21526567211009200</ispartof><rights>The Author(s) 2021</rights><rights>The Author(s) 2021.</rights><rights>The Author(s) 2021. This work is licensed under the Creative Commons Attribution – Non-Commercial License https://creativecommons.org/licenses/by-nc/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>The Author(s) 2021 2021 SAGE Publications Inc. unless otherwise noted. Manuscript content on this site is licensed under Creative Commons Licenses</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03</citedby><cites>FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03</cites><orcidid>0000-0002-9780-2485</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8040553/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2613228387?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,21965,25752,27852,27923,27924,37011,44589,44944,45332,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33889435$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Alokby, Ghassan</creatorcontrib><creatorcontrib>AlAmari, Kholoud Mohammed</creatorcontrib><creatorcontrib>Abdullah, Jamal Mohammed S.</creatorcontrib><creatorcontrib>Tayed Hazazi, Mohammed</creatorcontrib><creatorcontrib>Makki, Fawaz</creatorcontrib><title>Endoscopic Reconstruction of Skull Base Defects Using Tutoplast</title><title>Allergy & rhinology (Providence, R.I.)</title><addtitle>Allergy Rhinol (Providence)</addtitle><description>Background
Various graft materials that are classified as autografts, xenografts, and allografts based on their origin have been used to endoscopically repair skull base defects. Tutoplast® (Tutogen Medical GmbH), an allogeneic natural collagen matrix, is processed through chemical sterilization that preserves tissue biocompatibility and structural integrity.
Objective
To study the safety and efficacy of Tutoplast Fascia Lata and Tutoplast Temporalis Fascia® as primary graft materials in the endoscopic reconstruction of skull base defects of different sizes and etiologies and to compare the outcomes with those of other traditional graft materials based on our experience.
Methods
This is a multi-center retrospective chart review of patients who underwent cerebrospinal fluid leak (CSF) endoscopic reconstruction with Tutoplast Fascia Lata or Tutoplast Temporalis Fascia as either a stand-alone reconstruction material or a part of a multilayer reconstruction depending on the defect at Prince Sultan Military Medical City and King Faisal Specialist Hospital and Research Center in Riyadh, Saudi Arabia, between 2017 and 2020. Our inclusion criteria were CSF leak repair with Tutoplast and a transnasal endoscopic approach. We reviewed demographic data, intraoperative and postoperative complications, repair materials, repair failure, defect size and location.
Results
Tutoplast® was used as the primary graft material in 33 cases. Our main outcome was repair success with lack of post operative CSF leak, observed in 30 cases (90.9%). There was no significant association between postoperative CSF leaks and factors including different defect sizes, defect sites, demographic data, hospitalization duration, or postoperative radiation in oncological cases.
Conclusion
Tutoplast alone or in combination with other materials can be used safely and effectively for skull base defects repair.</description><subject>Allografts</subject><subject>Autografts</subject><subject>Biocompatibility</subject><subject>Cerebrospinal fluid</subject><subject>Collagen</subject><subject>Complications</subject><subject>Defects</subject><subject>Endoscopy</subject><subject>Fascia</subject><subject>Original</subject><subject>Postoperative</subject><subject>Skull</subject><subject>Sterilization</subject><subject>Xenografts</subject><issn>2152-6567</issn><issn>2152-6575</issn><issn>2152-6567</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNp1kV9rFTEQxYMottR-AF9kwedbJ_-TF0Vr1UJB0PY5ZCfJda_bzTXJFvz27vXW2iLOS4aTM79JOIQ8p3BCqdavGJVMSaUZpQCWATwihztttRMf3-sPyHGtG1iKW601fUoOODfGCi4PyZuzKeSKeTtg9yVinmorM7YhT11O3dfv8zh273yN3fuYIrbaXdVhWneXc8vb0df2jDxJfqzx-PY8Ilcfzi5PP60uPn88P317sUKhWFuZHrUxKiQbaVBUG0zUUkGFSN5iChFQYpCASnOlRQTPQrBoZVDa9wH4ETnfc0P2G7ctw7UvP132g_st5LJ2vrQBx-ggSuwT9ZyzXjBvvWcIoBPIQCmCWFiv96zt3F_HgHFqxY8PoA9vpuGbW-cbZ0CAlHwBvLwFlPxjjrW5TZ7LtPzfMUU5Y4Ybvbjo3oUl11piuttAwe0idP9EuMy8uP-0u4k_gS2Gk72h-nX8u_b_xF9g-6Nv</recordid><startdate>202101</startdate><enddate>202101</enddate><creator>Alokby, Ghassan</creator><creator>AlAmari, Kholoud Mohammed</creator><creator>Abdullah, Jamal Mohammed S.</creator><creator>Tayed Hazazi, Mohammed</creator><creator>Makki, Fawaz</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><general>SAGE Publishing</general><scope>AFRWT</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7T5</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9780-2485</orcidid></search><sort><creationdate>202101</creationdate><title>Endoscopic Reconstruction of Skull Base Defects Using Tutoplast</title><author>Alokby, Ghassan ; AlAmari, Kholoud Mohammed ; Abdullah, Jamal Mohammed S. ; Tayed Hazazi, Mohammed ; Makki, Fawaz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Allografts</topic><topic>Autografts</topic><topic>Biocompatibility</topic><topic>Cerebrospinal fluid</topic><topic>Collagen</topic><topic>Complications</topic><topic>Defects</topic><topic>Endoscopy</topic><topic>Fascia</topic><topic>Original</topic><topic>Postoperative</topic><topic>Skull</topic><topic>Sterilization</topic><topic>Xenografts</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Alokby, Ghassan</creatorcontrib><creatorcontrib>AlAmari, Kholoud Mohammed</creatorcontrib><creatorcontrib>Abdullah, Jamal Mohammed S.</creatorcontrib><creatorcontrib>Tayed Hazazi, Mohammed</creatorcontrib><creatorcontrib>Makki, Fawaz</creatorcontrib><collection>SAGE Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Immunology Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Allergy & rhinology (Providence, R.I.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Alokby, Ghassan</au><au>AlAmari, Kholoud Mohammed</au><au>Abdullah, Jamal Mohammed S.</au><au>Tayed Hazazi, Mohammed</au><au>Makki, Fawaz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endoscopic Reconstruction of Skull Base Defects Using Tutoplast</atitle><jtitle>Allergy & rhinology (Providence, R.I.)</jtitle><addtitle>Allergy Rhinol (Providence)</addtitle><date>2021-01</date><risdate>2021</risdate><volume>12</volume><spage>21526567211009200</spage><pages>21526567211009200-</pages><issn>2152-6567</issn><issn>2152-6575</issn><eissn>2152-6567</eissn><abstract>Background
Various graft materials that are classified as autografts, xenografts, and allografts based on their origin have been used to endoscopically repair skull base defects. Tutoplast® (Tutogen Medical GmbH), an allogeneic natural collagen matrix, is processed through chemical sterilization that preserves tissue biocompatibility and structural integrity.
Objective
To study the safety and efficacy of Tutoplast Fascia Lata and Tutoplast Temporalis Fascia® as primary graft materials in the endoscopic reconstruction of skull base defects of different sizes and etiologies and to compare the outcomes with those of other traditional graft materials based on our experience.
Methods
This is a multi-center retrospective chart review of patients who underwent cerebrospinal fluid leak (CSF) endoscopic reconstruction with Tutoplast Fascia Lata or Tutoplast Temporalis Fascia as either a stand-alone reconstruction material or a part of a multilayer reconstruction depending on the defect at Prince Sultan Military Medical City and King Faisal Specialist Hospital and Research Center in Riyadh, Saudi Arabia, between 2017 and 2020. Our inclusion criteria were CSF leak repair with Tutoplast and a transnasal endoscopic approach. We reviewed demographic data, intraoperative and postoperative complications, repair materials, repair failure, defect size and location.
Results
Tutoplast® was used as the primary graft material in 33 cases. Our main outcome was repair success with lack of post operative CSF leak, observed in 30 cases (90.9%). There was no significant association between postoperative CSF leaks and factors including different defect sizes, defect sites, demographic data, hospitalization duration, or postoperative radiation in oncological cases.
Conclusion
Tutoplast alone or in combination with other materials can be used safely and effectively for skull base defects repair.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>33889435</pmid><doi>10.1177/21526567211009200</doi><orcidid>https://orcid.org/0000-0002-9780-2485</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2152-6567 |
ispartof | Allergy & rhinology (Providence, R.I.), 2021-01, Vol.12, p.21526567211009200 |
issn | 2152-6567 2152-6575 2152-6567 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_0e5cbf1a332b42a9aa2c007f05d11c04 |
source | SAGE Open Access; Publicly Available Content Database; PubMed Central |
subjects | Allografts Autografts Biocompatibility Cerebrospinal fluid Collagen Complications Defects Endoscopy Fascia Original Postoperative Skull Sterilization Xenografts |
title | Endoscopic Reconstruction of Skull Base Defects Using Tutoplast |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T19%3A37%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endoscopic%20Reconstruction%20of%20Skull%20Base%20Defects%20Using%20Tutoplast&rft.jtitle=Allergy%20&%20rhinology%20(Providence,%20R.I.)&rft.au=Alokby,%20Ghassan&rft.date=2021-01&rft.volume=12&rft.spage=21526567211009200&rft.pages=21526567211009200-&rft.issn=2152-6567&rft.eissn=2152-6567&rft_id=info:doi/10.1177/21526567211009200&rft_dat=%3Cproquest_doaj_%3E2613228387%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c462t-8bc7886df9e1d6178cf1914144fa9cfde0c5cd50c673674e0a2dd9c95d67abd03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2613228387&rft_id=info:pmid/33889435&rft_sage_id=10.1177_21526567211009200&rfr_iscdi=true |