Loading…

Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC

This study evaluated the uniaxial tensile strength and bond performance of natural hybrid reinforcement bars. Hybrid FRP combines multiple fibers and matrixes, resulting in a desirable performance. Two types of hybrid bars were tested: one with natural fibers surrounded by glass fiber, and the other...

Full description

Saved in:
Bibliographic Details
Published in:Case Studies in Construction Materials 2024-12, Vol.21, p.e03442, Article e03442
Main Authors: Attia, Mohammed M., Olwan, Mahmoud Malek, Amoush, Essam, Aamer, Shady Rizk Ragheb Hassan, Eita, M.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c291t-b651f8c6bbae5f1aaa8e3d5c33449cfbaafe9446e4b25cfb5725e2ad9638d6033
container_end_page
container_issue
container_start_page e03442
container_title Case Studies in Construction Materials
container_volume 21
creator Attia, Mohammed M.
Olwan, Mahmoud Malek
Amoush, Essam
Aamer, Shady Rizk Ragheb Hassan
Eita, M.A.
description This study evaluated the uniaxial tensile strength and bond performance of natural hybrid reinforcement bars. Hybrid FRP combines multiple fibers and matrixes, resulting in a desirable performance. Two types of hybrid bars were tested: one with natural fibers surrounded by glass fiber, and the other with a steel core surrounded by natural fiber and then glass fiber. Thirteen samples were used to assess tensile behavior, with four groups including glass fiber, flax, sisal, and jute fibers. Pull-out behavior testing was conducted on twelve samples, divided into four groups of fiberglass, flax, sisal, and jute. Each group used three types of concrete: normal, high strength, and ultra-high-performance concrete (UHPC). The results refer to flax samples that had a higher tensile strength and elastic modulus of 143 MPa and 38 GPa, respectively, than samples made of sisal and jute fibres. The hybrid bars with a steel core exhibited a significant improvement in elastic modulus of 206 % in compared to samples made solely from glass, sisal, and jute fibers. On the other hand, the samples with UHPC showed the highest bond strength. The sample U-GFRP with ultra-high-performance concrete showed the highest bond strength 9.32 MPa, while the sample N-GFRP with normal concrete showed the lowest bond strength 5.87 MPa, respectively. However, this study suggests that hybridizing natural fibers can be a cost-effective and eco-friendly alternative to synthetic fibers.
doi_str_mv 10.1016/j.cscm.2024.e03442
format article
fullrecord <record><control><sourceid>elsevier_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_13bee19f037141ccbc45aae17ef1713f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S221450952400593X</els_id><doaj_id>oai_doaj_org_article_13bee19f037141ccbc45aae17ef1713f</doaj_id><sourcerecordid>S221450952400593X</sourcerecordid><originalsourceid>FETCH-LOGICAL-c291t-b651f8c6bbae5f1aaa8e3d5c33449cfbaafe9446e4b25cfb5725e2ad9638d6033</originalsourceid><addsrcrecordid>eNp9UctKAzEUHURBUX_AVX5gap7zADda1AqCLnQdbjI3NmU6kWSm2r83tSKu3Nz3Odx7T1FcMDpjlFWXq5lNdj3jlMsZUiElPyhOOGeyVLRVh3_i4-I8pRWllDeqanh9UmxucAkbHyIJjiy3JvqODDBOEXrivMFIIvrBhWixI--h364xJmIgm2nocnsaPHz6PD3ikHyPJI0Rh7dxSWDIiKnvyzCNpA_QJfLhc_118Tw_K44c9AnPf_xp8Xp3-zJflI9P9w_z68fS8paNpakUc42tjAFUjgFAg6JTVuQjW-sMgMNWygql4SrnquYKOXRtJZquokKcFg973i7ASr9Hv4a41QG8_i6E-KYhjt72qJkwiKx1VNRMMmuNlQoAWY2O1Uy4zMX3XDaGlCK6Xz5G9U4IvdI7IfROCL0XIoOu9iDMV248Rp2sxyF_00e0Y17D_wf_AgyblLg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC</title><source>ScienceDirect®</source><creator>Attia, Mohammed M. ; Olwan, Mahmoud Malek ; Amoush, Essam ; Aamer, Shady Rizk Ragheb Hassan ; Eita, M.A.</creator><creatorcontrib>Attia, Mohammed M. ; Olwan, Mahmoud Malek ; Amoush, Essam ; Aamer, Shady Rizk Ragheb Hassan ; Eita, M.A.</creatorcontrib><description>This study evaluated the uniaxial tensile strength and bond performance of natural hybrid reinforcement bars. Hybrid FRP combines multiple fibers and matrixes, resulting in a desirable performance. Two types of hybrid bars were tested: one with natural fibers surrounded by glass fiber, and the other with a steel core surrounded by natural fiber and then glass fiber. Thirteen samples were used to assess tensile behavior, with four groups including glass fiber, flax, sisal, and jute fibers. Pull-out behavior testing was conducted on twelve samples, divided into four groups of fiberglass, flax, sisal, and jute. Each group used three types of concrete: normal, high strength, and ultra-high-performance concrete (UHPC). The results refer to flax samples that had a higher tensile strength and elastic modulus of 143 MPa and 38 GPa, respectively, than samples made of sisal and jute fibres. The hybrid bars with a steel core exhibited a significant improvement in elastic modulus of 206 % in compared to samples made solely from glass, sisal, and jute fibers. On the other hand, the samples with UHPC showed the highest bond strength. The sample U-GFRP with ultra-high-performance concrete showed the highest bond strength 9.32 MPa, while the sample N-GFRP with normal concrete showed the lowest bond strength 5.87 MPa, respectively. However, this study suggests that hybridizing natural fibers can be a cost-effective and eco-friendly alternative to synthetic fibers.</description><identifier>ISSN: 2214-5095</identifier><identifier>EISSN: 2214-5095</identifier><identifier>DOI: 10.1016/j.cscm.2024.e03442</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>GFRP ; Hybrid fiber ; Natural fiber ; Pull-out strength ; UHPC</subject><ispartof>Case Studies in Construction Materials, 2024-12, Vol.21, p.e03442, Article e03442</ispartof><rights>2024 The Authors</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c291t-b651f8c6bbae5f1aaa8e3d5c33449cfbaafe9446e4b25cfb5725e2ad9638d6033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S221450952400593X$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,3547,27923,27924,45779</link.rule.ids></links><search><creatorcontrib>Attia, Mohammed M.</creatorcontrib><creatorcontrib>Olwan, Mahmoud Malek</creatorcontrib><creatorcontrib>Amoush, Essam</creatorcontrib><creatorcontrib>Aamer, Shady Rizk Ragheb Hassan</creatorcontrib><creatorcontrib>Eita, M.A.</creatorcontrib><title>Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC</title><title>Case Studies in Construction Materials</title><description>This study evaluated the uniaxial tensile strength and bond performance of natural hybrid reinforcement bars. Hybrid FRP combines multiple fibers and matrixes, resulting in a desirable performance. Two types of hybrid bars were tested: one with natural fibers surrounded by glass fiber, and the other with a steel core surrounded by natural fiber and then glass fiber. Thirteen samples were used to assess tensile behavior, with four groups including glass fiber, flax, sisal, and jute fibers. Pull-out behavior testing was conducted on twelve samples, divided into four groups of fiberglass, flax, sisal, and jute. Each group used three types of concrete: normal, high strength, and ultra-high-performance concrete (UHPC). The results refer to flax samples that had a higher tensile strength and elastic modulus of 143 MPa and 38 GPa, respectively, than samples made of sisal and jute fibres. The hybrid bars with a steel core exhibited a significant improvement in elastic modulus of 206 % in compared to samples made solely from glass, sisal, and jute fibers. On the other hand, the samples with UHPC showed the highest bond strength. The sample U-GFRP with ultra-high-performance concrete showed the highest bond strength 9.32 MPa, while the sample N-GFRP with normal concrete showed the lowest bond strength 5.87 MPa, respectively. However, this study suggests that hybridizing natural fibers can be a cost-effective and eco-friendly alternative to synthetic fibers.</description><subject>GFRP</subject><subject>Hybrid fiber</subject><subject>Natural fiber</subject><subject>Pull-out strength</subject><subject>UHPC</subject><issn>2214-5095</issn><issn>2214-5095</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9UctKAzEUHURBUX_AVX5gap7zADda1AqCLnQdbjI3NmU6kWSm2r83tSKu3Nz3Odx7T1FcMDpjlFWXq5lNdj3jlMsZUiElPyhOOGeyVLRVh3_i4-I8pRWllDeqanh9UmxucAkbHyIJjiy3JvqODDBOEXrivMFIIvrBhWixI--h364xJmIgm2nocnsaPHz6PD3ikHyPJI0Rh7dxSWDIiKnvyzCNpA_QJfLhc_118Tw_K44c9AnPf_xp8Xp3-zJflI9P9w_z68fS8paNpakUc42tjAFUjgFAg6JTVuQjW-sMgMNWygql4SrnquYKOXRtJZquokKcFg973i7ASr9Hv4a41QG8_i6E-KYhjt72qJkwiKx1VNRMMmuNlQoAWY2O1Uy4zMX3XDaGlCK6Xz5G9U4IvdI7IfROCL0XIoOu9iDMV248Rp2sxyF_00e0Y17D_wf_AgyblLg</recordid><startdate>202412</startdate><enddate>202412</enddate><creator>Attia, Mohammed M.</creator><creator>Olwan, Mahmoud Malek</creator><creator>Amoush, Essam</creator><creator>Aamer, Shady Rizk Ragheb Hassan</creator><creator>Eita, M.A.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>202412</creationdate><title>Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC</title><author>Attia, Mohammed M. ; Olwan, Mahmoud Malek ; Amoush, Essam ; Aamer, Shady Rizk Ragheb Hassan ; Eita, M.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c291t-b651f8c6bbae5f1aaa8e3d5c33449cfbaafe9446e4b25cfb5725e2ad9638d6033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>GFRP</topic><topic>Hybrid fiber</topic><topic>Natural fiber</topic><topic>Pull-out strength</topic><topic>UHPC</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Attia, Mohammed M.</creatorcontrib><creatorcontrib>Olwan, Mahmoud Malek</creatorcontrib><creatorcontrib>Amoush, Essam</creatorcontrib><creatorcontrib>Aamer, Shady Rizk Ragheb Hassan</creatorcontrib><creatorcontrib>Eita, M.A.</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Case Studies in Construction Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Attia, Mohammed M.</au><au>Olwan, Mahmoud Malek</au><au>Amoush, Essam</au><au>Aamer, Shady Rizk Ragheb Hassan</au><au>Eita, M.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC</atitle><jtitle>Case Studies in Construction Materials</jtitle><date>2024-12</date><risdate>2024</risdate><volume>21</volume><spage>e03442</spage><pages>e03442-</pages><artnum>e03442</artnum><issn>2214-5095</issn><eissn>2214-5095</eissn><abstract>This study evaluated the uniaxial tensile strength and bond performance of natural hybrid reinforcement bars. Hybrid FRP combines multiple fibers and matrixes, resulting in a desirable performance. Two types of hybrid bars were tested: one with natural fibers surrounded by glass fiber, and the other with a steel core surrounded by natural fiber and then glass fiber. Thirteen samples were used to assess tensile behavior, with four groups including glass fiber, flax, sisal, and jute fibers. Pull-out behavior testing was conducted on twelve samples, divided into four groups of fiberglass, flax, sisal, and jute. Each group used three types of concrete: normal, high strength, and ultra-high-performance concrete (UHPC). The results refer to flax samples that had a higher tensile strength and elastic modulus of 143 MPa and 38 GPa, respectively, than samples made of sisal and jute fibres. The hybrid bars with a steel core exhibited a significant improvement in elastic modulus of 206 % in compared to samples made solely from glass, sisal, and jute fibers. On the other hand, the samples with UHPC showed the highest bond strength. The sample U-GFRP with ultra-high-performance concrete showed the highest bond strength 9.32 MPa, while the sample N-GFRP with normal concrete showed the lowest bond strength 5.87 MPa, respectively. However, this study suggests that hybridizing natural fibers can be a cost-effective and eco-friendly alternative to synthetic fibers.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.cscm.2024.e03442</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2214-5095
ispartof Case Studies in Construction Materials, 2024-12, Vol.21, p.e03442, Article e03442
issn 2214-5095
2214-5095
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_13bee19f037141ccbc45aae17ef1713f
source ScienceDirect®
subjects GFRP
Hybrid fiber
Natural fiber
Pull-out strength
UHPC
title Behavior of hybrid natural fiber reinforced polymers bars under uniaxial tensile strength and pull-out loads with UHPC
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-10T14%3A31%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Behavior%20of%20hybrid%20natural%20fiber%20reinforced%20polymers%20bars%20under%20uniaxial%20tensile%20strength%20and%20pull-out%20loads%20with%20UHPC&rft.jtitle=Case%20Studies%20in%20Construction%20Materials&rft.au=Attia,%20Mohammed%20M.&rft.date=2024-12&rft.volume=21&rft.spage=e03442&rft.pages=e03442-&rft.artnum=e03442&rft.issn=2214-5095&rft.eissn=2214-5095&rft_id=info:doi/10.1016/j.cscm.2024.e03442&rft_dat=%3Celsevier_doaj_%3ES221450952400593X%3C/elsevier_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c291t-b651f8c6bbae5f1aaa8e3d5c33449cfbaafe9446e4b25cfb5725e2ad9638d6033%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true