Loading…
Postoperative prosthetic mitral valve occlusion due to left atrial thrombus during veno-arterial extracorporeal membrane oxygenation: a case report
Background Anticoagulation using heparin is generally used to prevent thrombus formation during mechanical circulatory support, such as veno-arterial extracorporeal membrane oxygenation (VA-ECMO). However, during the early period following cardiac surgery, anticoagulation becomes more difficult due...
Saved in:
Published in: | JA clinical reports 2022-12, Vol.8 (1), p.93-93, Article 93 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
Anticoagulation using heparin is generally used to prevent thrombus formation during mechanical circulatory support, such as veno-arterial extracorporeal membrane oxygenation (VA-ECMO). However, during the early period following cardiac surgery, anticoagulation becomes more difficult due to the greater risk of critical bleeding complications.
Case presentation
A 71-year-old man presented with acute prosthetic valve occlusion caused by left atrial thrombus formation and bioprosthetic valve thrombosis during peripheral VA-ECMO following mitral valve replacement (MVR) despite continuous heparin administration and loading of antiplatelet agents. The VA-ECMO flow rate decreased 10 h after the intensive care unit (ICU) admission after MVR. Exploratory transesophageal echocardiography (TEE) examination revealed a left atrial thrombus, prosthetic valve obstruction by the thrombus, and an intrapericardial hematoma.
Conclusions
Intracardiac thrombus formation might occur during VA-ECMO despite appropriate anticoagulation and loading of antiplatelet agents. Exploratory TEE examination was helpful in the detection of intra-atrial thrombus formation after cardiac surgery and surgical decision-making. |
---|---|