Coil embolization of a celiac artery pseudoaneurysm under balloon-assisted flow control: A case report

Coil migration can occur when coil embolization is used for treating pseudoaneurysms associated with large arteries. The double microcatheter technique is useful for preventing coil migration; the balloon catheter can reduce blood flow and active bleeding upon balloon inflation, and can also compres...

Full description

Saved in:
Bibliographic Details
Published in:Radiology case reports 2024-06, Vol.19 (6), p.2282-2285
Main Authors: Sekino, Hirofumi, Ishii, Shiro, Ishigame, Teruhide, Ando, Tatsuya, Kawamoto, Natsumi, Endo, Yoshiki, Kuroiwa, Daichi, Ito, Hiroshi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Coil migration can occur when coil embolization is used for treating pseudoaneurysms associated with large arteries. The double microcatheter technique is useful for preventing coil migration; the balloon catheter can reduce blood flow and active bleeding upon balloon inflation, and can also compress the bleeding point and arrest bleeding temporarily. We report a case describing the management of a pseudoaneurysm with coil embolization using double microcatheters and a balloon catheter to control blood flow and prevent coil migration. A 73-year-old male patient presented with a pseudoaneurysm of the celiac artery arising from the splenic artery stump following surgery. Coil embolization of the pseudoaneurysm using a double microcatheter embolization technique with a balloon catheter was considered. A balloon catheter was inserted into the celiac artery and active bleeding was temporarily arrested with the inflated balloon. First, a microcatheter was inserted into the balloon catheter, and another microcatheter was placed in the celiac artery. An electrical detachable coil was inserted into the proximal common hepatic artery just distal to the pseudoaneurysm. The second electrically detachable coil was inserted while the first coil remained attached. After detachment of the second coil, additional electrically detachable coils were inserted for similar embolization. The balloon was gradually deflated. Finally, the first coil was detached and we confirmed absence of the bleeding. Our case report demonstrated that a balloon catheter can control the flow vessels, and the double microcatheter embolization technique with a balloon catheter is useful for coil embolization in high-flow or large vessels.
ISSN:1930-0433
1930-0433
DOI:10.1016/j.radcr.2024.02.076