A modified technique for fabrication of custom-made afterload brachytherapy appliance
Radiotherapy for carcinomas that involve the mouth and its related structures has been improved by the usage of different prostheses known as radiation carriers. These prostheses can accurately position radionuclide such as radium, iridium, cesium, and cobalt to allow adequate transfer of a concentr...
Saved in:
Published in: | The journal of Indian Prosthodontic Society 2019-01, Vol.19 (1), p.79-82 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c607d-672d15f5ded644f515c99afe712a8e88f76cc4d2e3f8041c2b9fc79075c24cbf3 |
---|---|
cites | |
container_end_page | 82 |
container_issue | 1 |
container_start_page | 79 |
container_title | The journal of Indian Prosthodontic Society |
container_volume | 19 |
creator | Jain, Sumeet Agrawal, Namrata Dwivedi, Aparna Bajaj, Shobhit |
description | Radiotherapy for carcinomas that involve the mouth and its related structures has been improved by the usage of different prostheses known as radiation carriers. These prostheses can accurately position radionuclide such as radium, iridium, cesium, and cobalt to allow adequate transfer of a concentrated radiation dose to a tumor region. At the same time, they minimize the exposure to radiation of nearby tissues due to rapid fall-off the radioactivity and thus minimizing the side effects of radiation. This study emphasizes the usage of a modified technique for the development of afterload mold brachytherapy appliance for squamous cell carcinoma patients of hard palate/soft palate. |
doi_str_mv | 10.4103/jips.jips_8_18 |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_19b04df195d5412b8c8820942a980fec</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A569078151</galeid><doaj_id>oai_doaj_org_article_19b04df195d5412b8c8820942a980fec</doaj_id><sourcerecordid>A569078151</sourcerecordid><originalsourceid>FETCH-LOGICAL-c607d-672d15f5ded644f515c99afe712a8e88f76cc4d2e3f8041c2b9fc79075c24cbf3</originalsourceid><addsrcrecordid>eNp1kt9r2zAQx83YWLNur3schsHekkmyZEkvg1D2o1DYy_os5JMUK7UtT7IX8t9PadqsgQ6BdJy-90F3-hbFe4xWFKPq89aPaXXYlFBYvCgWWEqxpIjxl8UCSU4OMbko3qS0RYgJJOjr4qJCnDLOxKK4XZd9MN55a8rJQjv437MtXYil0030oCcfhjK4EuY0hX7Za2NL7SYbu6BN2UQN7X5qbdTjvtTj2Hk9gH1bvHK6S_bdw3lZ3H77-uvqx_Lm5_frq_XNEmrEzbLmxGDmmLGmptQxzEBK7SzHRAsrhOM1ADXEVk4gioE00gGXiDMgFBpXXRbXR64JeqvG6Hsd9ypor-4TIW6UjpOHziosG0SNw5IZRjFpBAhBkKRES4Gchcz6cmSNc9NbA3aYou7OoOc3g2_VJvxRdUUREjwDPj4AYshDTJPahjkOuX9FcF0jLGhd_1NtdH6VH1zIMOh9ArVmde5NYIazavWMKi9jew9hsM7n_FnBpycFrdXd1KbQzYfvS8-SIYaUonWnDjFSB0upezedLJULPjydy0n-6KEsWB8Fu9BlX6S7bt7ZqLL2bgi7_2AVl2qtHq1X_QXVruCh</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2166018466</pqid></control><display><type>article</type><title>A modified technique for fabrication of custom-made afterload brachytherapy appliance</title><source>Publicly Available Content Database</source><source>Medknow Open Access Medical Journals</source><source>PubMed Central</source><creator>Jain, Sumeet ; Agrawal, Namrata ; Dwivedi, Aparna ; Bajaj, Shobhit</creator><creatorcontrib>Jain, Sumeet ; Agrawal, Namrata ; Dwivedi, Aparna ; Bajaj, Shobhit</creatorcontrib><description>Radiotherapy for carcinomas that involve the mouth and its related structures has been improved by the usage of different prostheses known as radiation carriers. These prostheses can accurately position radionuclide such as radium, iridium, cesium, and cobalt to allow adequate transfer of a concentrated radiation dose to a tumor region. At the same time, they minimize the exposure to radiation of nearby tissues due to rapid fall-off the radioactivity and thus minimizing the side effects of radiation. This study emphasizes the usage of a modified technique for the development of afterload mold brachytherapy appliance for squamous cell carcinoma patients of hard palate/soft palate.</description><identifier>ISSN: 0972-4052</identifier><identifier>EISSN: 1998-4057</identifier><identifier>DOI: 10.4103/jips.jips_8_18</identifier><identifier>PMID: 30745758</identifier><language>eng</language><publisher>India: Wolters Kluwer India Pvt. Ltd</publisher><subject>Baby foods ; Brachytherapy ; Care and treatment ; Case Report ; Cesium ; Cobalt ; Dental equipment ; Equipment and supplies ; High-dose-rate brachytherapy ; intraoral mold ; Materials ; Medical imaging ; Methods ; Mouth cancer ; Palate ; Properties ; Prostheses ; Prosthetics ; Radiation therapy ; Radioactivity ; radiotherapy ; Radium ; Squamous cell carcinoma</subject><ispartof>The journal of Indian Prosthodontic Society, 2019-01, Vol.19 (1), p.79-82</ispartof><rights>COPYRIGHT 2019 Medknow Publications and Media Pvt. Ltd.</rights><rights>2019. This work is published under https://creativecommons.org/licenses/by-nc-sa/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Copyright: © 2019 The Journal of Indian Prosthodontic Society 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c607d-672d15f5ded644f515c99afe712a8e88f76cc4d2e3f8041c2b9fc79075c24cbf3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6340087/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2166018466?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,4024,25753,27458,27923,27924,27925,37012,44590,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30745758$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jain, Sumeet</creatorcontrib><creatorcontrib>Agrawal, Namrata</creatorcontrib><creatorcontrib>Dwivedi, Aparna</creatorcontrib><creatorcontrib>Bajaj, Shobhit</creatorcontrib><title>A modified technique for fabrication of custom-made afterload brachytherapy appliance</title><title>The journal of Indian Prosthodontic Society</title><addtitle>J Indian Prosthodont Soc</addtitle><description>Radiotherapy for carcinomas that involve the mouth and its related structures has been improved by the usage of different prostheses known as radiation carriers. These prostheses can accurately position radionuclide such as radium, iridium, cesium, and cobalt to allow adequate transfer of a concentrated radiation dose to a tumor region. At the same time, they minimize the exposure to radiation of nearby tissues due to rapid fall-off the radioactivity and thus minimizing the side effects of radiation. This study emphasizes the usage of a modified technique for the development of afterload mold brachytherapy appliance for squamous cell carcinoma patients of hard palate/soft palate.</description><subject>Baby foods</subject><subject>Brachytherapy</subject><subject>Care and treatment</subject><subject>Case Report</subject><subject>Cesium</subject><subject>Cobalt</subject><subject>Dental equipment</subject><subject>Equipment and supplies</subject><subject>High-dose-rate brachytherapy</subject><subject>intraoral mold</subject><subject>Materials</subject><subject>Medical imaging</subject><subject>Methods</subject><subject>Mouth cancer</subject><subject>Palate</subject><subject>Properties</subject><subject>Prostheses</subject><subject>Prosthetics</subject><subject>Radiation therapy</subject><subject>Radioactivity</subject><subject>radiotherapy</subject><subject>Radium</subject><subject>Squamous cell carcinoma</subject><issn>0972-4052</issn><issn>1998-4057</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNp1kt9r2zAQx83YWLNur3schsHekkmyZEkvg1D2o1DYy_os5JMUK7UtT7IX8t9PadqsgQ6BdJy-90F3-hbFe4xWFKPq89aPaXXYlFBYvCgWWEqxpIjxl8UCSU4OMbko3qS0RYgJJOjr4qJCnDLOxKK4XZd9MN55a8rJQjv437MtXYil0030oCcfhjK4EuY0hX7Za2NL7SYbu6BN2UQN7X5qbdTjvtTj2Hk9gH1bvHK6S_bdw3lZ3H77-uvqx_Lm5_frq_XNEmrEzbLmxGDmmLGmptQxzEBK7SzHRAsrhOM1ADXEVk4gioE00gGXiDMgFBpXXRbXR64JeqvG6Hsd9ypor-4TIW6UjpOHziosG0SNw5IZRjFpBAhBkKRES4Gchcz6cmSNc9NbA3aYou7OoOc3g2_VJvxRdUUREjwDPj4AYshDTJPahjkOuX9FcF0jLGhd_1NtdH6VH1zIMOh9ArVmde5NYIazavWMKi9jew9hsM7n_FnBpycFrdXd1KbQzYfvS8-SIYaUonWnDjFSB0upezedLJULPjydy0n-6KEsWB8Fu9BlX6S7bt7ZqLL2bgi7_2AVl2qtHq1X_QXVruCh</recordid><startdate>20190101</startdate><enddate>20190101</enddate><creator>Jain, Sumeet</creator><creator>Agrawal, Namrata</creator><creator>Dwivedi, Aparna</creator><creator>Bajaj, Shobhit</creator><general>Wolters Kluwer India Pvt. Ltd</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20190101</creationdate><title>A modified technique for fabrication of custom-made afterload brachytherapy appliance</title><author>Jain, Sumeet ; Agrawal, Namrata ; Dwivedi, Aparna ; Bajaj, Shobhit</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c607d-672d15f5ded644f515c99afe712a8e88f76cc4d2e3f8041c2b9fc79075c24cbf3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Baby foods</topic><topic>Brachytherapy</topic><topic>Care and treatment</topic><topic>Case Report</topic><topic>Cesium</topic><topic>Cobalt</topic><topic>Dental equipment</topic><topic>Equipment and supplies</topic><topic>High-dose-rate brachytherapy</topic><topic>intraoral mold</topic><topic>Materials</topic><topic>Medical imaging</topic><topic>Methods</topic><topic>Mouth cancer</topic><topic>Palate</topic><topic>Properties</topic><topic>Prostheses</topic><topic>Prosthetics</topic><topic>Radiation therapy</topic><topic>Radioactivity</topic><topic>radiotherapy</topic><topic>Radium</topic><topic>Squamous cell carcinoma</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jain, Sumeet</creatorcontrib><creatorcontrib>Agrawal, Namrata</creatorcontrib><creatorcontrib>Dwivedi, Aparna</creatorcontrib><creatorcontrib>Bajaj, Shobhit</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Proquest Health and Medical Complete</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>The journal of Indian Prosthodontic Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jain, Sumeet</au><au>Agrawal, Namrata</au><au>Dwivedi, Aparna</au><au>Bajaj, Shobhit</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A modified technique for fabrication of custom-made afterload brachytherapy appliance</atitle><jtitle>The journal of Indian Prosthodontic Society</jtitle><addtitle>J Indian Prosthodont Soc</addtitle><date>2019-01-01</date><risdate>2019</risdate><volume>19</volume><issue>1</issue><spage>79</spage><epage>82</epage><pages>79-82</pages><issn>0972-4052</issn><eissn>1998-4057</eissn><abstract>Radiotherapy for carcinomas that involve the mouth and its related structures has been improved by the usage of different prostheses known as radiation carriers. These prostheses can accurately position radionuclide such as radium, iridium, cesium, and cobalt to allow adequate transfer of a concentrated radiation dose to a tumor region. At the same time, they minimize the exposure to radiation of nearby tissues due to rapid fall-off the radioactivity and thus minimizing the side effects of radiation. This study emphasizes the usage of a modified technique for the development of afterload mold brachytherapy appliance for squamous cell carcinoma patients of hard palate/soft palate.</abstract><cop>India</cop><pub>Wolters Kluwer India Pvt. Ltd</pub><pmid>30745758</pmid><doi>10.4103/jips.jips_8_18</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0972-4052 |
ispartof | The journal of Indian Prosthodontic Society, 2019-01, Vol.19 (1), p.79-82 |
issn | 0972-4052 1998-4057 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_19b04df195d5412b8c8820942a980fec |
source | Publicly Available Content Database; Medknow Open Access Medical Journals; PubMed Central |
subjects | Baby foods Brachytherapy Care and treatment Case Report Cesium Cobalt Dental equipment Equipment and supplies High-dose-rate brachytherapy intraoral mold Materials Medical imaging Methods Mouth cancer Palate Properties Prostheses Prosthetics Radiation therapy Radioactivity radiotherapy Radium Squamous cell carcinoma |
title | A modified technique for fabrication of custom-made afterload brachytherapy appliance |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T00%3A09%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20modified%20technique%20for%20fabrication%20of%20custom-made%20afterload%20brachytherapy%20appliance&rft.jtitle=The%20journal%20of%20Indian%20Prosthodontic%20Society&rft.au=Jain,%20Sumeet&rft.date=2019-01-01&rft.volume=19&rft.issue=1&rft.spage=79&rft.epage=82&rft.pages=79-82&rft.issn=0972-4052&rft.eissn=1998-4057&rft_id=info:doi/10.4103/jips.jips_8_18&rft_dat=%3Cgale_doaj_%3EA569078151%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c607d-672d15f5ded644f515c99afe712a8e88f76cc4d2e3f8041c2b9fc79075c24cbf3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2166018466&rft_id=info:pmid/30745758&rft_galeid=A569078151&rfr_iscdi=true |