Embodied Energy and Environmental Impact of Large-Power Stand-Alone Photovoltaic Irrigation Systems

A life cycle assessment (LCA) methodology was used to evaluate the cumulative energy demand and the related environmental impact of three large-power stand-alone photovoltaic (PV) irrigation systems ranging from 40 kWp to 360 kWp. The novelty of this analysis is the large power of these systems as t...

Full description

Saved in:
Bibliographic Details
Published in:Energies (Basel) 2018-08, Vol.11 (8), p.2110
Main Authors: Todde, Giuseppe, Murgia, Lelia, Carrelo, Isaac, Hogan, Rita, Pazzona, Antonio, Ledda, Luigi, Narvarte, Luis
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A life cycle assessment (LCA) methodology was used to evaluate the cumulative energy demand and the related environmental impact of three large-power stand-alone photovoltaic (PV) irrigation systems ranging from 40 kWp to 360 kWp. The novelty of this analysis is the large power of these systems as the literature up to now is restricted to modeled PV pumping systems scenarios or small power plants, where the size can be a critical factor for energy and environmental issues. The analysis shows that the yearly embodied energy per unit of PV power ranged from 1306 MJ/kWp to 1199 MJ/kWp depending of the PV generator size. Similarly, the related yearly carbon dioxide impacts ranged from 72.6 to 79.8 kg CO2e/kWp. The production of PV modules accounted for the main portion (about 80%) of the primary energy embodied into the PV irrigation system (PVIS). The outcomes of the study also show an inverse trend of the energy and carbon payback times respect to the PV power size: In fact, energy payback time increased from 1.94, to 5.25 years and carbon payback time ranged from 4.62 to 9.38 years. Also the energy return on investment depends on the PV generator dimension, ranging from 12.9 to 4.8. The environmental impact of the stand-alone PV systems was also expressed in reference to the potential amount of electricity generated during the whole PV life. As expected, the largest PVIS performs the best result, obtaining an emission rate of 45.9 g CO2e per kWh, while the smallest one achieves 124.1 g CO2e per kWh. Finally, the energy and environmental indicators obtained in this study are strongly related to the irrigation needs, which in turn are influenced by other factors as the type of cultivated crops, the weather conditions and the water availability.
ISSN:1996-1073
1996-1073
DOI:10.3390/en11082110