Loading…

Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format

Lateral-flow immunoassays (LFIAs) are a widely used point-of-care technology because they are simple to perform and easy to read. LFIAs typically use colloidal gold or colored latex beads, however the sensitivity of LFIAs is ultimately limited by the label's extinction coefficients as enough ma...

Full description

Saved in:
Bibliographic Details
Published in:Sensing and Bio-Sensing Research 2020-12, Vol.30, p.100390, Article 100390
Main Authors: Mulvaney, Shawn P., Kidwell, David A., Lanese, Jillian N., Lopez, Riley P., Sumera, Mia E., Wei, Eric
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73
cites cdi_FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73
container_end_page
container_issue
container_start_page 100390
container_title Sensing and Bio-Sensing Research
container_volume 30
creator Mulvaney, Shawn P.
Kidwell, David A.
Lanese, Jillian N.
Lopez, Riley P.
Sumera, Mia E.
Wei, Eric
description Lateral-flow immunoassays (LFIAs) are a widely used point-of-care technology because they are simple to perform and easy to read. LFIAs typically use colloidal gold or colored latex beads, however the sensitivity of LFIAs is ultimately limited by the label's extinction coefficients as enough material must be localized to be observed. Greater sensitivity requires visualization of fewer labels and herein we substitute palladium nanoparticles as a catalyst to produce a stable, blue indamine dye that precipitates at the capture line. We term our system cLFIA™ for catalytic LFIAs. The catalytic chemistry requires that three chemicals react with the palladium, and we have incorporate all three elements onto the cLFIA™ in the chemistry release fiber (CRF). With the CRF, cLFIA™ strips operate exactly as traditional LFIA strips, requiring no additional steps from the user, however the resulting lines are blue not red and provide much greater sensitivity. The all-in-one nature of cLFIA™ assays and the nature of the Pd conjugates we utilize sets this technology apart from other approaches that enhance LFIA sensitivity. We demonstrate that 2 nm Pd nanoparticles have a 40× catalytic advantage over 50 nm Pd-coated nanoparticles for our dye system. Our dye system is more robust than common peroxidase dyes (TMB), providing 8× signal and at a fast rate. Lastly, we demonstrate that the cLFIA™ approach is 1000× more sensitivity for detection of human chorionic gonadotropin than commercial pregnancy assays. The preparation of the palladium catalyst, the dye chemistry, and their facile use in cLFIA™ assays are described. •Catalytic lateral flow immunoassays are multiple orders of magnitude more sensitive than traditional LFA or LFIA assays.•cLFIA™ assays are a simple, one-step, POC diagnostic. The user adds sample & run buffer and waits for the result in 2-20 min.•Palladium nanoparticles convert an indamine dye into a stable blue precipitate that is easily observable by eye.•Our Pd system is a robust alternative to nanozymes that convert peroxidase based substrates such as TMB, DAB, or OPD.
doi_str_mv 10.1016/j.sbsr.2020.100390
format article
fullrecord <record><control><sourceid>elsevier_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_1ae77d61327741618b0b943fae00581d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2214180420302154</els_id><doaj_id>oai_doaj_org_article_1ae77d61327741618b0b943fae00581d</doaj_id><sourcerecordid>S2214180420302154</sourcerecordid><originalsourceid>FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73</originalsourceid><addsrcrecordid>eNp9kL9OwzAQhyMEElXpCzB5hCHF5zhxiliqikKlSiwwWxfHrhzlT2UHUHeehEfjSXAahJiYbN3d79PdF0WXQOdAIbup5r7wbs4oGwo0WdCTaMIY8Bhyyk___M-jmfcVpRRElkHOJhGusMf60FtFauy1w5qYunsntmle2w69x4MnV2q73iy_Pj6vb8my2dfWWF0Sb3dtGLctQeJ1bWLVtT3aNrSOOWI612B_EZ0ZrL2e_bzT6GV9_7x6jLdPD5vVchsrDrSPM8W5AqGpKAvGGFcFYJlyAFHkSZ4l3KApFQpRUi4wzyE1AkxRaJ3miTIimUabkVt2WMm9sw26g-zQymOhczuJLtxZawmoAyeDhAnBIYgoaLHgiUFNaZpDGVhsZCnXee-0-eUBlYNzWcnBuRycy9F5CN2NIR2ufLPaSa-sbpUurdOqD2vY_-LfrNuKpQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format</title><source>ScienceDirect Journals</source><creator>Mulvaney, Shawn P. ; Kidwell, David A. ; Lanese, Jillian N. ; Lopez, Riley P. ; Sumera, Mia E. ; Wei, Eric</creator><creatorcontrib>Mulvaney, Shawn P. ; Kidwell, David A. ; Lanese, Jillian N. ; Lopez, Riley P. ; Sumera, Mia E. ; Wei, Eric</creatorcontrib><description>Lateral-flow immunoassays (LFIAs) are a widely used point-of-care technology because they are simple to perform and easy to read. LFIAs typically use colloidal gold or colored latex beads, however the sensitivity of LFIAs is ultimately limited by the label's extinction coefficients as enough material must be localized to be observed. Greater sensitivity requires visualization of fewer labels and herein we substitute palladium nanoparticles as a catalyst to produce a stable, blue indamine dye that precipitates at the capture line. We term our system cLFIA™ for catalytic LFIAs. The catalytic chemistry requires that three chemicals react with the palladium, and we have incorporate all three elements onto the cLFIA™ in the chemistry release fiber (CRF). With the CRF, cLFIA™ strips operate exactly as traditional LFIA strips, requiring no additional steps from the user, however the resulting lines are blue not red and provide much greater sensitivity. The all-in-one nature of cLFIA™ assays and the nature of the Pd conjugates we utilize sets this technology apart from other approaches that enhance LFIA sensitivity. We demonstrate that 2 nm Pd nanoparticles have a 40× catalytic advantage over 50 nm Pd-coated nanoparticles for our dye system. Our dye system is more robust than common peroxidase dyes (TMB), providing 8× signal and at a fast rate. Lastly, we demonstrate that the cLFIA™ approach is 1000× more sensitivity for detection of human chorionic gonadotropin than commercial pregnancy assays. The preparation of the palladium catalyst, the dye chemistry, and their facile use in cLFIA™ assays are described. •Catalytic lateral flow immunoassays are multiple orders of magnitude more sensitive than traditional LFA or LFIA assays.•cLFIA™ assays are a simple, one-step, POC diagnostic. The user adds sample &amp; run buffer and waits for the result in 2-20 min.•Palladium nanoparticles convert an indamine dye into a stable blue precipitate that is easily observable by eye.•Our Pd system is a robust alternative to nanozymes that convert peroxidase based substrates such as TMB, DAB, or OPD.</description><identifier>ISSN: 2214-1804</identifier><identifier>EISSN: 2214-1804</identifier><identifier>DOI: 10.1016/j.sbsr.2020.100390</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Catalytic amplification ; Diagnostic technology ; Lateral-flow immunoassays (LFIs or LFIAs) ; Nanozyme ; Point-of-care</subject><ispartof>Sensing and Bio-Sensing Research, 2020-12, Vol.30, p.100390, Article 100390</ispartof><rights>2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73</citedby><cites>FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2214180420302154$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,3535,27903,27904,45759</link.rule.ids></links><search><creatorcontrib>Mulvaney, Shawn P.</creatorcontrib><creatorcontrib>Kidwell, David A.</creatorcontrib><creatorcontrib>Lanese, Jillian N.</creatorcontrib><creatorcontrib>Lopez, Riley P.</creatorcontrib><creatorcontrib>Sumera, Mia E.</creatorcontrib><creatorcontrib>Wei, Eric</creatorcontrib><title>Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format</title><title>Sensing and Bio-Sensing Research</title><description>Lateral-flow immunoassays (LFIAs) are a widely used point-of-care technology because they are simple to perform and easy to read. LFIAs typically use colloidal gold or colored latex beads, however the sensitivity of LFIAs is ultimately limited by the label's extinction coefficients as enough material must be localized to be observed. Greater sensitivity requires visualization of fewer labels and herein we substitute palladium nanoparticles as a catalyst to produce a stable, blue indamine dye that precipitates at the capture line. We term our system cLFIA™ for catalytic LFIAs. The catalytic chemistry requires that three chemicals react with the palladium, and we have incorporate all three elements onto the cLFIA™ in the chemistry release fiber (CRF). With the CRF, cLFIA™ strips operate exactly as traditional LFIA strips, requiring no additional steps from the user, however the resulting lines are blue not red and provide much greater sensitivity. The all-in-one nature of cLFIA™ assays and the nature of the Pd conjugates we utilize sets this technology apart from other approaches that enhance LFIA sensitivity. We demonstrate that 2 nm Pd nanoparticles have a 40× catalytic advantage over 50 nm Pd-coated nanoparticles for our dye system. Our dye system is more robust than common peroxidase dyes (TMB), providing 8× signal and at a fast rate. Lastly, we demonstrate that the cLFIA™ approach is 1000× more sensitivity for detection of human chorionic gonadotropin than commercial pregnancy assays. The preparation of the palladium catalyst, the dye chemistry, and their facile use in cLFIA™ assays are described. •Catalytic lateral flow immunoassays are multiple orders of magnitude more sensitive than traditional LFA or LFIA assays.•cLFIA™ assays are a simple, one-step, POC diagnostic. The user adds sample &amp; run buffer and waits for the result in 2-20 min.•Palladium nanoparticles convert an indamine dye into a stable blue precipitate that is easily observable by eye.•Our Pd system is a robust alternative to nanozymes that convert peroxidase based substrates such as TMB, DAB, or OPD.</description><subject>Catalytic amplification</subject><subject>Diagnostic technology</subject><subject>Lateral-flow immunoassays (LFIs or LFIAs)</subject><subject>Nanozyme</subject><subject>Point-of-care</subject><issn>2214-1804</issn><issn>2214-1804</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kL9OwzAQhyMEElXpCzB5hCHF5zhxiliqikKlSiwwWxfHrhzlT2UHUHeehEfjSXAahJiYbN3d79PdF0WXQOdAIbup5r7wbs4oGwo0WdCTaMIY8Bhyyk___M-jmfcVpRRElkHOJhGusMf60FtFauy1w5qYunsntmle2w69x4MnV2q73iy_Pj6vb8my2dfWWF0Sb3dtGLctQeJ1bWLVtT3aNrSOOWI612B_EZ0ZrL2e_bzT6GV9_7x6jLdPD5vVchsrDrSPM8W5AqGpKAvGGFcFYJlyAFHkSZ4l3KApFQpRUi4wzyE1AkxRaJ3miTIimUabkVt2WMm9sw26g-zQymOhczuJLtxZawmoAyeDhAnBIYgoaLHgiUFNaZpDGVhsZCnXee-0-eUBlYNzWcnBuRycy9F5CN2NIR2ufLPaSa-sbpUurdOqD2vY_-LfrNuKpQ</recordid><startdate>202012</startdate><enddate>202012</enddate><creator>Mulvaney, Shawn P.</creator><creator>Kidwell, David A.</creator><creator>Lanese, Jillian N.</creator><creator>Lopez, Riley P.</creator><creator>Sumera, Mia E.</creator><creator>Wei, Eric</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>202012</creationdate><title>Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format</title><author>Mulvaney, Shawn P. ; Kidwell, David A. ; Lanese, Jillian N. ; Lopez, Riley P. ; Sumera, Mia E. ; Wei, Eric</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Catalytic amplification</topic><topic>Diagnostic technology</topic><topic>Lateral-flow immunoassays (LFIs or LFIAs)</topic><topic>Nanozyme</topic><topic>Point-of-care</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mulvaney, Shawn P.</creatorcontrib><creatorcontrib>Kidwell, David A.</creatorcontrib><creatorcontrib>Lanese, Jillian N.</creatorcontrib><creatorcontrib>Lopez, Riley P.</creatorcontrib><creatorcontrib>Sumera, Mia E.</creatorcontrib><creatorcontrib>Wei, Eric</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>DOAJ: Directory of Open Access Journals</collection><jtitle>Sensing and Bio-Sensing Research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mulvaney, Shawn P.</au><au>Kidwell, David A.</au><au>Lanese, Jillian N.</au><au>Lopez, Riley P.</au><au>Sumera, Mia E.</au><au>Wei, Eric</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format</atitle><jtitle>Sensing and Bio-Sensing Research</jtitle><date>2020-12</date><risdate>2020</risdate><volume>30</volume><spage>100390</spage><pages>100390-</pages><artnum>100390</artnum><issn>2214-1804</issn><eissn>2214-1804</eissn><abstract>Lateral-flow immunoassays (LFIAs) are a widely used point-of-care technology because they are simple to perform and easy to read. LFIAs typically use colloidal gold or colored latex beads, however the sensitivity of LFIAs is ultimately limited by the label's extinction coefficients as enough material must be localized to be observed. Greater sensitivity requires visualization of fewer labels and herein we substitute palladium nanoparticles as a catalyst to produce a stable, blue indamine dye that precipitates at the capture line. We term our system cLFIA™ for catalytic LFIAs. The catalytic chemistry requires that three chemicals react with the palladium, and we have incorporate all three elements onto the cLFIA™ in the chemistry release fiber (CRF). With the CRF, cLFIA™ strips operate exactly as traditional LFIA strips, requiring no additional steps from the user, however the resulting lines are blue not red and provide much greater sensitivity. The all-in-one nature of cLFIA™ assays and the nature of the Pd conjugates we utilize sets this technology apart from other approaches that enhance LFIA sensitivity. We demonstrate that 2 nm Pd nanoparticles have a 40× catalytic advantage over 50 nm Pd-coated nanoparticles for our dye system. Our dye system is more robust than common peroxidase dyes (TMB), providing 8× signal and at a fast rate. Lastly, we demonstrate that the cLFIA™ approach is 1000× more sensitivity for detection of human chorionic gonadotropin than commercial pregnancy assays. The preparation of the palladium catalyst, the dye chemistry, and their facile use in cLFIA™ assays are described. •Catalytic lateral flow immunoassays are multiple orders of magnitude more sensitive than traditional LFA or LFIA assays.•cLFIA™ assays are a simple, one-step, POC diagnostic. The user adds sample &amp; run buffer and waits for the result in 2-20 min.•Palladium nanoparticles convert an indamine dye into a stable blue precipitate that is easily observable by eye.•Our Pd system is a robust alternative to nanozymes that convert peroxidase based substrates such as TMB, DAB, or OPD.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.sbsr.2020.100390</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2214-1804
ispartof Sensing and Bio-Sensing Research, 2020-12, Vol.30, p.100390, Article 100390
issn 2214-1804
2214-1804
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_1ae77d61327741618b0b943fae00581d
source ScienceDirect Journals
subjects Catalytic amplification
Diagnostic technology
Lateral-flow immunoassays (LFIs or LFIAs)
Nanozyme
Point-of-care
title Catalytic lateral flow immunoassays (cLFIA™): Amplified signal in a self-contained assay format
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T22%3A47%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Catalytic%20lateral%20flow%20immunoassays%20(cLFIA%E2%84%A2):%20Amplified%20signal%20in%20a%20self-contained%20assay%20format&rft.jtitle=Sensing%20and%20Bio-Sensing%20Research&rft.au=Mulvaney,%20Shawn%20P.&rft.date=2020-12&rft.volume=30&rft.spage=100390&rft.pages=100390-&rft.artnum=100390&rft.issn=2214-1804&rft.eissn=2214-1804&rft_id=info:doi/10.1016/j.sbsr.2020.100390&rft_dat=%3Celsevier_doaj_%3ES2214180420302154%3C/elsevier_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c410t-6c44c17e07db2224cb1ad54117b838634fafdca77d047a8815f71fbbee583cf73%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true