Loading…

Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine

This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This s...

Full description

Saved in:
Bibliographic Details
Published in:Analytica 2024-11, Vol.5 (4), p.587-598
Main Authors: Keklik Şah, Gül, Isbir Turan, Aybüke A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c1779-323ea3eaffc82d300122c049372b99e3f689db29af0624a3504f7a801c3db5413
container_end_page 598
container_issue 4
container_start_page 587
container_title Analytica
container_volume 5
creator Keklik Şah, Gül
Isbir Turan, Aybüke A.
description This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.
doi_str_mv 10.3390/analytica5040039
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_210f14aea44b4e27b400cce786fe27ab</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_210f14aea44b4e27b400cce786fe27ab</doaj_id><sourcerecordid>3149497959</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1779-323ea3eaffc82d300122c049372b99e3f689db29af0624a3504f7a801c3db5413</originalsourceid><addsrcrecordid>eNpdUU1LAzEQDaJg0d49BjxX87WbzbHUjxYKirbnMJtNypZtUpPdQv-90YqIMMN88HjDvIfQDSV3nCtyDx66Y98aKIgghKszNGKl5BNRcHb-p79E45S2hBAmlShKOUKrhffhAH17sPh9iA6Mxa8dpF3w-M2m4MHnzXTfQ7I-hYhdzgfbW9O3foNnwUDrLW49ng878Hgd83iNLhx0yY5_6hVaPz2uZvPJ8uV5MZsuJ4ZKqSaccQs5nDMVazghlDFDhOKS1UpZ7spKNTVT4EjJBPD8nJNQEWp4UxeC8iu0OPE2AbZ6H9sdxKMO0OrvRYgbDTHL0lnNKHFUgAUhamGZrLNOxlhZlS5PUGeu2xPXPoaPwaZeb8MQs65JcyqUUFIVKqPICWViSCla93uVEv1lhf5vBf8ED099aw</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3149497959</pqid></control><display><type>article</type><title>Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine</title><source>Publicly Available Content Database</source><creator>Keklik Şah, Gül ; Isbir Turan, Aybüke A.</creator><creatorcontrib>Keklik Şah, Gül ; Isbir Turan, Aybüke A.</creatorcontrib><description>This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.</description><identifier>ISSN: 2673-4532</identifier><identifier>EISSN: 2673-4532</identifier><identifier>DOI: 10.3390/analytica5040039</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>aptamer ; Biomarkers ; Biosensors ; Chromatography ; Cocaine ; Contact angle ; Cost analysis ; Environmental monitoring ; Enzymes ; Gold ; gold nanoparticle ; Homogeneity ; Immunoassay ; Isotherms ; Laboratories ; Methods ; Nanoparticles ; Sensors ; surface characterization ; Surface plasmon resonance ; Surface roughness ; synthetic urine ; Urine</subject><ispartof>Analytica, 2024-11, Vol.5 (4), p.587-598</ispartof><rights>2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1779-323ea3eaffc82d300122c049372b99e3f689db29af0624a3504f7a801c3db5413</cites><orcidid>0000-0002-3650-7810</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/3149497959/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/3149497959?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25751,27922,27923,37010,44588,74896</link.rule.ids></links><search><creatorcontrib>Keklik Şah, Gül</creatorcontrib><creatorcontrib>Isbir Turan, Aybüke A.</creatorcontrib><title>Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine</title><title>Analytica</title><description>This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.</description><subject>aptamer</subject><subject>Biomarkers</subject><subject>Biosensors</subject><subject>Chromatography</subject><subject>Cocaine</subject><subject>Contact angle</subject><subject>Cost analysis</subject><subject>Environmental monitoring</subject><subject>Enzymes</subject><subject>Gold</subject><subject>gold nanoparticle</subject><subject>Homogeneity</subject><subject>Immunoassay</subject><subject>Isotherms</subject><subject>Laboratories</subject><subject>Methods</subject><subject>Nanoparticles</subject><subject>Sensors</subject><subject>surface characterization</subject><subject>Surface plasmon resonance</subject><subject>Surface roughness</subject><subject>synthetic urine</subject><subject>Urine</subject><issn>2673-4532</issn><issn>2673-4532</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdUU1LAzEQDaJg0d49BjxX87WbzbHUjxYKirbnMJtNypZtUpPdQv-90YqIMMN88HjDvIfQDSV3nCtyDx66Y98aKIgghKszNGKl5BNRcHb-p79E45S2hBAmlShKOUKrhffhAH17sPh9iA6Mxa8dpF3w-M2m4MHnzXTfQ7I-hYhdzgfbW9O3foNnwUDrLW49ng878Hgd83iNLhx0yY5_6hVaPz2uZvPJ8uV5MZsuJ4ZKqSaccQs5nDMVazghlDFDhOKS1UpZ7spKNTVT4EjJBPD8nJNQEWp4UxeC8iu0OPE2AbZ6H9sdxKMO0OrvRYgbDTHL0lnNKHFUgAUhamGZrLNOxlhZlS5PUGeu2xPXPoaPwaZeb8MQs65JcyqUUFIVKqPICWViSCla93uVEv1lhf5vBf8ED099aw</recordid><startdate>20241128</startdate><enddate>20241128</enddate><creator>Keklik Şah, Gül</creator><creator>Isbir Turan, Aybüke A.</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-3650-7810</orcidid></search><sort><creationdate>20241128</creationdate><title>Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine</title><author>Keklik Şah, Gül ; Isbir Turan, Aybüke A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1779-323ea3eaffc82d300122c049372b99e3f689db29af0624a3504f7a801c3db5413</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>aptamer</topic><topic>Biomarkers</topic><topic>Biosensors</topic><topic>Chromatography</topic><topic>Cocaine</topic><topic>Contact angle</topic><topic>Cost analysis</topic><topic>Environmental monitoring</topic><topic>Enzymes</topic><topic>Gold</topic><topic>gold nanoparticle</topic><topic>Homogeneity</topic><topic>Immunoassay</topic><topic>Isotherms</topic><topic>Laboratories</topic><topic>Methods</topic><topic>Nanoparticles</topic><topic>Sensors</topic><topic>surface characterization</topic><topic>Surface plasmon resonance</topic><topic>Surface roughness</topic><topic>synthetic urine</topic><topic>Urine</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Keklik Şah, Gül</creatorcontrib><creatorcontrib>Isbir Turan, Aybüke A.</creatorcontrib><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Analytica</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Keklik Şah, Gül</au><au>Isbir Turan, Aybüke A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine</atitle><jtitle>Analytica</jtitle><date>2024-11-28</date><risdate>2024</risdate><volume>5</volume><issue>4</issue><spage>587</spage><epage>598</epage><pages>587-598</pages><issn>2673-4532</issn><eissn>2673-4532</eissn><abstract>This study describes the development of an optical-based surface plasmon resonance (SPR) aptasensor for the detection of cocaine. The aptasensor was prepared by first attaching gold nanoparticles to a clean SPR chip surface, followed by the addition of an aptamer to create a modified surface. This surface was characterized using contact angle and atomic force microscopy, revealing surface roughness values of 0.28 nm and 28.12 nm for the blank and modified surfaces, respectively. The detection of cocaine was carried out in the concentration range of 1 ng/mL to 1000 ng/mL, with a detection time of approximately 8 min and a cocaine limit of detection (LOD) of 0.43 ng/mL. Repeatability studies were conducted, and the stability of the signal response was examined at a concentration of 200 ng/mL. Adsorption isotherm models, including Scatchard, Langmuir, and Freundlich models, were calculated to assess the surface homogeneity of the SPR aptasensor chip, with the results indicating compatibility with the Langmuir isotherm model.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/analytica5040039</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0002-3650-7810</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2673-4532
ispartof Analytica, 2024-11, Vol.5 (4), p.587-598
issn 2673-4532
2673-4532
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_210f14aea44b4e27b400cce786fe27ab
source Publicly Available Content Database
subjects aptamer
Biomarkers
Biosensors
Chromatography
Cocaine
Contact angle
Cost analysis
Environmental monitoring
Enzymes
Gold
gold nanoparticle
Homogeneity
Immunoassay
Isotherms
Laboratories
Methods
Nanoparticles
Sensors
surface characterization
Surface plasmon resonance
Surface roughness
synthetic urine
Urine
title Innovative Surface Plasmon Resonance Aptasensor for Detecting Cocaine in Human Urine
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T11%3A38%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Innovative%20Surface%20Plasmon%20Resonance%20Aptasensor%20for%20Detecting%20Cocaine%20in%20Human%20Urine&rft.jtitle=Analytica&rft.au=Keklik%20%C5%9Eah,%20G%C3%BCl&rft.date=2024-11-28&rft.volume=5&rft.issue=4&rft.spage=587&rft.epage=598&rft.pages=587-598&rft.issn=2673-4532&rft.eissn=2673-4532&rft_id=info:doi/10.3390/analytica5040039&rft_dat=%3Cproquest_doaj_%3E3149497959%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1779-323ea3eaffc82d300122c049372b99e3f689db29af0624a3504f7a801c3db5413%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3149497959&rft_id=info:pmid/&rfr_iscdi=true