Loading…

WATER-PERFUSED HIGH-RESOLUTION ANORECTAL MANOMETRY (HRAM-WP): THE FIRST BRAZILIAN STUDY

High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other syste...

Full description

Saved in:
Bibliographic Details
Published in:Arquivos de gastroenterologia 2018-11, Vol.55Suppl 1 (Suppl 1), p.41-46
Main Authors: Viebig, Ricardo Guilherme, Franco, Janaina Tomiye Yamakata, Araujo, Sergio Viebig, Gualberto, Daniel
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:High resolution anorectal manometry (HRAM-WP) allows more simplified, objective, and uniform data acquisition and interpretation of the test results. To validate a HRAM under water perfusion (Alacer Biomédica) with a 24-channel probe and to compare the results of anorectal manometry with other systems. Individuals without critical evacuation disorders were selected. Patients with incontinence, anal surgery, dyssynergia or sphincter injury were excluded. The test was performed with an Alacer Biomédica 24 channel manometry system under water perfusion, with a probe configured with 6 levels of 4 radial channels, separated from each other by 0.8 mm. The mean pressures for the functional channel were determined, in states of rest (RMP), contention effort (CMP) and evacuation effort (EEMP). The pressure extension of the sphincter was also tabulated in cm. The results were compared with those available in recent literature. Fifty patients were studied (20 men; 30 women). Overall, the following results were obtained: the RMP was 76.9±3.0 mmHg, the CMP was 194.2±9.4 mmHg, and EEMP was 88.2±3.7 mmHg. When classified according to the gender, for men: RMP was 72.2±3.0 mmHg, CMP was 229.5±17 mmHg, and EEMP was 91.4±7.0. For women, RMP was 79.8±4.0 mmHg, CMP was 170.7±8, and EEMP was 86.1±4.3 mmHg. The sphincter gauge extension for both genders was 3.1±0.09 cm (men 3.3±0.1; women 3.0±0.1). Studying HRAM-WP has become much easier. Non-mobilization of the sensor causes less discomfort and artefacts with a lower assessment time. In this study, small differential values between both sexes during rest were observed, highlighting a greater containment force in men. No difference in sphincter extension was noted. The results of this study are consistent with that of existing reports and with those obtained using solid state probes. The perfusion system yielded results similar to that of solid state systems. Further studies to evaluate parameters with respect to pelvic dyssynergia and incontinence need to be conducted. Additionally, to determine if the vector volume can furnish new information in terms of functional and anatomical aspects.
ISSN:0004-2803
1678-4219
1678-4219
DOI:10.1590/s0004-2803.201800000-38