Motion-correction strategies for enhancing whole-body PET imaging
Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been develo...
Saved in:
Published in: | Frontiers in nuclear medicine 2024, Vol.4 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23 |
container_end_page | |
container_issue | |
container_start_page | |
container_title | Frontiers in nuclear medicine |
container_volume | 4 |
creator | Wang, James Bermudez, Dalton Chen, Weijie Durgavarjhula, Divya Randell, Caitlin Uyanik, Meltem McMillan, Alan |
description | Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging. |
doi_str_mv | 10.3389/fnume.2024.1257880 |
format | article |
fullrecord | <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b</doaj_id><sourcerecordid>3090947411</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</originalsourceid><addsrcrecordid>eNpVUU1PGzEUtKqiEgX-AIdqj71s8Nf641RFUQpIVHCAs-WPt5tFmzW1N6349zgkRXB6o_GbmWcNQhcELxhT-rIdd1tYUEz5gtBGKoW_oBkVktWq4K8f8Ck6z_kJY0yl4hTzb-iUaUKUFnyGlr_j1Mex9jEl8HtY5SnZCboectXGVMG4saPvx676t4kD1C6Gl-p-_VD1W9sV-gydtHbIcH6cc_T4a_2wuq5v765uVsvb2pfQqZZKaO1aJb3TnvGG69C4IAqUhaBBOSkZAeklBKJAC4mbMrDSSjnhKJujm4NviPbJPKcSn15MtL15I2LqjE1T7wcwtKwzERopHOMuOC29sgK8Iq3nmrri9fPg9bxzWwgexvLn4ZPp55ex35gu_jWEMKwavL_mx9EhxT87yJPZ9tnDMNgR4i4bhjXWXPIimCN6WPUp5pygfc8h2Oy7NG9dmn2X5thlEX3_eOG75H9z7BUg1pud</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3090947411</pqid></control><display><type>article</type><title>Motion-correction strategies for enhancing whole-body PET imaging</title><source>PubMed Central (Open access)</source><source>DOAJ Directory of Open Access Journals</source><creator>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</creator><creatorcontrib>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</creatorcontrib><description>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</description><identifier>ISSN: 2673-8880</identifier><identifier>EISSN: 2673-8880</identifier><identifier>DOI: 10.3389/fnume.2024.1257880</identifier><identifier>PMID: 39118964</identifier><language>eng</language><publisher>Switzerland: Frontiers Media S.A</publisher><subject>cardiac gating ; data-driven gating ; hardware-driven gating ; motion correction ; positron emission tomography (PET) ; respiratory gating</subject><ispartof>Frontiers in nuclear medicine, 2024, Vol.4</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308502/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308502/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,2101,4023,27922,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39118964$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, James</creatorcontrib><creatorcontrib>Bermudez, Dalton</creatorcontrib><creatorcontrib>Chen, Weijie</creatorcontrib><creatorcontrib>Durgavarjhula, Divya</creatorcontrib><creatorcontrib>Randell, Caitlin</creatorcontrib><creatorcontrib>Uyanik, Meltem</creatorcontrib><creatorcontrib>McMillan, Alan</creatorcontrib><title>Motion-correction strategies for enhancing whole-body PET imaging</title><title>Frontiers in nuclear medicine</title><addtitle>Front Nucl Med</addtitle><description>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</description><subject>cardiac gating</subject><subject>data-driven gating</subject><subject>hardware-driven gating</subject><subject>motion correction</subject><subject>positron emission tomography (PET)</subject><subject>respiratory gating</subject><issn>2673-8880</issn><issn>2673-8880</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVUU1PGzEUtKqiEgX-AIdqj71s8Nf641RFUQpIVHCAs-WPt5tFmzW1N6349zgkRXB6o_GbmWcNQhcELxhT-rIdd1tYUEz5gtBGKoW_oBkVktWq4K8f8Ck6z_kJY0yl4hTzb-iUaUKUFnyGlr_j1Mex9jEl8HtY5SnZCboectXGVMG4saPvx676t4kD1C6Gl-p-_VD1W9sV-gydtHbIcH6cc_T4a_2wuq5v765uVsvb2pfQqZZKaO1aJb3TnvGG69C4IAqUhaBBOSkZAeklBKJAC4mbMrDSSjnhKJujm4NviPbJPKcSn15MtL15I2LqjE1T7wcwtKwzERopHOMuOC29sgK8Iq3nmrri9fPg9bxzWwgexvLn4ZPp55ex35gu_jWEMKwavL_mx9EhxT87yJPZ9tnDMNgR4i4bhjXWXPIimCN6WPUp5pygfc8h2Oy7NG9dmn2X5thlEX3_eOG75H9z7BUg1pud</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Wang, James</creator><creator>Bermudez, Dalton</creator><creator>Chen, Weijie</creator><creator>Durgavarjhula, Divya</creator><creator>Randell, Caitlin</creator><creator>Uyanik, Meltem</creator><creator>McMillan, Alan</creator><general>Frontiers Media S.A</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>2024</creationdate><title>Motion-correction strategies for enhancing whole-body PET imaging</title><author>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>cardiac gating</topic><topic>data-driven gating</topic><topic>hardware-driven gating</topic><topic>motion correction</topic><topic>positron emission tomography (PET)</topic><topic>respiratory gating</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, James</creatorcontrib><creatorcontrib>Bermudez, Dalton</creatorcontrib><creatorcontrib>Chen, Weijie</creatorcontrib><creatorcontrib>Durgavarjhula, Divya</creatorcontrib><creatorcontrib>Randell, Caitlin</creatorcontrib><creatorcontrib>Uyanik, Meltem</creatorcontrib><creatorcontrib>McMillan, Alan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Frontiers in nuclear medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, James</au><au>Bermudez, Dalton</au><au>Chen, Weijie</au><au>Durgavarjhula, Divya</au><au>Randell, Caitlin</au><au>Uyanik, Meltem</au><au>McMillan, Alan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Motion-correction strategies for enhancing whole-body PET imaging</atitle><jtitle>Frontiers in nuclear medicine</jtitle><addtitle>Front Nucl Med</addtitle><date>2024</date><risdate>2024</risdate><volume>4</volume><issn>2673-8880</issn><eissn>2673-8880</eissn><abstract>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</abstract><cop>Switzerland</cop><pub>Frontiers Media S.A</pub><pmid>39118964</pmid><doi>10.3389/fnume.2024.1257880</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2673-8880 |
ispartof | Frontiers in nuclear medicine, 2024, Vol.4 |
issn | 2673-8880 2673-8880 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b |
source | PubMed Central (Open access); DOAJ Directory of Open Access Journals |
subjects | cardiac gating data-driven gating hardware-driven gating motion correction positron emission tomography (PET) respiratory gating |
title | Motion-correction strategies for enhancing whole-body PET imaging |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A38%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Motion-correction%20strategies%20for%20enhancing%20whole-body%20PET%20imaging&rft.jtitle=Frontiers%20in%20nuclear%20medicine&rft.au=Wang,%20James&rft.date=2024&rft.volume=4&rft.issn=2673-8880&rft.eissn=2673-8880&rft_id=info:doi/10.3389/fnume.2024.1257880&rft_dat=%3Cproquest_doaj_%3E3090947411%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3090947411&rft_id=info:pmid/39118964&rfr_iscdi=true |