Motion-correction strategies for enhancing whole-body PET imaging

Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been develo...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in nuclear medicine 2024, Vol.4
Main Authors: Wang, James, Bermudez, Dalton, Chen, Weijie, Durgavarjhula, Divya, Randell, Caitlin, Uyanik, Meltem, McMillan, Alan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23
container_end_page
container_issue
container_start_page
container_title Frontiers in nuclear medicine
container_volume 4
creator Wang, James
Bermudez, Dalton
Chen, Weijie
Durgavarjhula, Divya
Randell, Caitlin
Uyanik, Meltem
McMillan, Alan
description Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.
doi_str_mv 10.3389/fnume.2024.1257880
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b</doaj_id><sourcerecordid>3090947411</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</originalsourceid><addsrcrecordid>eNpVUU1PGzEUtKqiEgX-AIdqj71s8Nf641RFUQpIVHCAs-WPt5tFmzW1N6349zgkRXB6o_GbmWcNQhcELxhT-rIdd1tYUEz5gtBGKoW_oBkVktWq4K8f8Ck6z_kJY0yl4hTzb-iUaUKUFnyGlr_j1Mex9jEl8HtY5SnZCboectXGVMG4saPvx676t4kD1C6Gl-p-_VD1W9sV-gydtHbIcH6cc_T4a_2wuq5v765uVsvb2pfQqZZKaO1aJb3TnvGG69C4IAqUhaBBOSkZAeklBKJAC4mbMrDSSjnhKJujm4NviPbJPKcSn15MtL15I2LqjE1T7wcwtKwzERopHOMuOC29sgK8Iq3nmrri9fPg9bxzWwgexvLn4ZPp55ex35gu_jWEMKwavL_mx9EhxT87yJPZ9tnDMNgR4i4bhjXWXPIimCN6WPUp5pygfc8h2Oy7NG9dmn2X5thlEX3_eOG75H9z7BUg1pud</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3090947411</pqid></control><display><type>article</type><title>Motion-correction strategies for enhancing whole-body PET imaging</title><source>PubMed Central (Open access)</source><source>DOAJ Directory of Open Access Journals</source><creator>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</creator><creatorcontrib>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</creatorcontrib><description>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</description><identifier>ISSN: 2673-8880</identifier><identifier>EISSN: 2673-8880</identifier><identifier>DOI: 10.3389/fnume.2024.1257880</identifier><identifier>PMID: 39118964</identifier><language>eng</language><publisher>Switzerland: Frontiers Media S.A</publisher><subject>cardiac gating ; data-driven gating ; hardware-driven gating ; motion correction ; positron emission tomography (PET) ; respiratory gating</subject><ispartof>Frontiers in nuclear medicine, 2024, Vol.4</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308502/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC11308502/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,864,885,2101,4023,27922,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39118964$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, James</creatorcontrib><creatorcontrib>Bermudez, Dalton</creatorcontrib><creatorcontrib>Chen, Weijie</creatorcontrib><creatorcontrib>Durgavarjhula, Divya</creatorcontrib><creatorcontrib>Randell, Caitlin</creatorcontrib><creatorcontrib>Uyanik, Meltem</creatorcontrib><creatorcontrib>McMillan, Alan</creatorcontrib><title>Motion-correction strategies for enhancing whole-body PET imaging</title><title>Frontiers in nuclear medicine</title><addtitle>Front Nucl Med</addtitle><description>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</description><subject>cardiac gating</subject><subject>data-driven gating</subject><subject>hardware-driven gating</subject><subject>motion correction</subject><subject>positron emission tomography (PET)</subject><subject>respiratory gating</subject><issn>2673-8880</issn><issn>2673-8880</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVUU1PGzEUtKqiEgX-AIdqj71s8Nf641RFUQpIVHCAs-WPt5tFmzW1N6349zgkRXB6o_GbmWcNQhcELxhT-rIdd1tYUEz5gtBGKoW_oBkVktWq4K8f8Ck6z_kJY0yl4hTzb-iUaUKUFnyGlr_j1Mex9jEl8HtY5SnZCboectXGVMG4saPvx676t4kD1C6Gl-p-_VD1W9sV-gydtHbIcH6cc_T4a_2wuq5v765uVsvb2pfQqZZKaO1aJb3TnvGG69C4IAqUhaBBOSkZAeklBKJAC4mbMrDSSjnhKJujm4NviPbJPKcSn15MtL15I2LqjE1T7wcwtKwzERopHOMuOC29sgK8Iq3nmrri9fPg9bxzWwgexvLn4ZPp55ex35gu_jWEMKwavL_mx9EhxT87yJPZ9tnDMNgR4i4bhjXWXPIimCN6WPUp5pygfc8h2Oy7NG9dmn2X5thlEX3_eOG75H9z7BUg1pud</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Wang, James</creator><creator>Bermudez, Dalton</creator><creator>Chen, Weijie</creator><creator>Durgavarjhula, Divya</creator><creator>Randell, Caitlin</creator><creator>Uyanik, Meltem</creator><creator>McMillan, Alan</creator><general>Frontiers Media S.A</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>2024</creationdate><title>Motion-correction strategies for enhancing whole-body PET imaging</title><author>Wang, James ; Bermudez, Dalton ; Chen, Weijie ; Durgavarjhula, Divya ; Randell, Caitlin ; Uyanik, Meltem ; McMillan, Alan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>cardiac gating</topic><topic>data-driven gating</topic><topic>hardware-driven gating</topic><topic>motion correction</topic><topic>positron emission tomography (PET)</topic><topic>respiratory gating</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, James</creatorcontrib><creatorcontrib>Bermudez, Dalton</creatorcontrib><creatorcontrib>Chen, Weijie</creatorcontrib><creatorcontrib>Durgavarjhula, Divya</creatorcontrib><creatorcontrib>Randell, Caitlin</creatorcontrib><creatorcontrib>Uyanik, Meltem</creatorcontrib><creatorcontrib>McMillan, Alan</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Frontiers in nuclear medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, James</au><au>Bermudez, Dalton</au><au>Chen, Weijie</au><au>Durgavarjhula, Divya</au><au>Randell, Caitlin</au><au>Uyanik, Meltem</au><au>McMillan, Alan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Motion-correction strategies for enhancing whole-body PET imaging</atitle><jtitle>Frontiers in nuclear medicine</jtitle><addtitle>Front Nucl Med</addtitle><date>2024</date><risdate>2024</risdate><volume>4</volume><issn>2673-8880</issn><eissn>2673-8880</eissn><abstract>Positron Emission Tomography (PET) is a powerful medical imaging technique widely used for detection and monitoring of disease. However, PET imaging can be adversely affected by patient motion, leading to degraded image quality and diagnostic capability. Hence, motion gating schemes have been developed to monitor various motion sources including head motion, respiratory motion, and cardiac motion. The approaches for these techniques have commonly come in the form of hardware-driven gating and data-driven gating, where the distinguishing aspect is the use of external hardware to make motion measurements vs. deriving these measures from the data itself. The implementation of these techniques helps correct for motion artifacts and improves tracer uptake measurements. With the great impact that these methods have on the diagnostic and quantitative quality of PET images, much research has been performed in this area, and this paper outlines the various approaches that have been developed as applied to whole-body PET imaging.</abstract><cop>Switzerland</cop><pub>Frontiers Media S.A</pub><pmid>39118964</pmid><doi>10.3389/fnume.2024.1257880</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2673-8880
ispartof Frontiers in nuclear medicine, 2024, Vol.4
issn 2673-8880
2673-8880
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_2b2336d576b34bdb97c8a6ec81fc492b
source PubMed Central (Open access); DOAJ Directory of Open Access Journals
subjects cardiac gating
data-driven gating
hardware-driven gating
motion correction
positron emission tomography (PET)
respiratory gating
title Motion-correction strategies for enhancing whole-body PET imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A38%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Motion-correction%20strategies%20for%20enhancing%20whole-body%20PET%20imaging&rft.jtitle=Frontiers%20in%20nuclear%20medicine&rft.au=Wang,%20James&rft.date=2024&rft.volume=4&rft.issn=2673-8880&rft.eissn=2673-8880&rft_id=info:doi/10.3389/fnume.2024.1257880&rft_dat=%3Cproquest_doaj_%3E3090947411%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-78699bf87cb9c34549d5bd6c347b9c2d8b7731e7c7ed18e967058e908988b6b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3090947411&rft_id=info:pmid/39118964&rfr_iscdi=true