Loading…
Study on Seismic Performance and Damage Analysis of Steel Plate Shear Wall with Partially Encased Composite (PEC) Columns
A steel plate shear wall often uses partially encased composite (PEC) columns instead of edge frame columns. Such a steel plate shear wall not only bears the gravity load of the structure and resists the bending moment caused by lateral force by taking advantage of the high bearing capacity and bend...
Saved in:
Published in: | Applied sciences 2019-03, Vol.9 (5), p.907 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A steel plate shear wall often uses partially encased composite (PEC) columns instead of edge frame columns. Such a steel plate shear wall not only bears the gravity load of the structure and resists the bending moment caused by lateral force by taking advantage of the high bearing capacity and bending stiffness of PEC columns, but also effectively anchors with the frame column to counteract the tension field generated by the steel plate. Therefore, the performance of the steel plate shear wall after buckling can be fully exerted and the seismic performance of the structure can be improved. In order to investigate the seismic performance of the structure, a 1/3-scale specimen test of steel plate shear wall with PEC columns is designed and fabricated, and a finite element model is established with the same size of test. It is found that the test and simulation results are in good agreement, which confirms the reliability of the simulation. Subsequently, 20 models with different parameters of steel plate shear wall with PEC columns are analyzed using ABAQUS. Finally, the failure mode, hysteretic behavior, skeleton curve, and bearing capacity of steel plate shear wall with PEC columns are obtained. The results show that PEC columns have a good anchoring effect on the diagonal tension field and can fully exert the plasticity of the infill steel plate, so that steel plate shear wall with PEC columns has superior seismic performance. Experiments also reveal that the crack type of damages appear in a steel plate shear wall with PEC columns, and, as a future work, the authors will explore the use of structural health monitoring methods, such as piezoceramic transducer-based method, to monitor such cracks. |
---|---|
ISSN: | 2076-3417 2076-3417 |
DOI: | 10.3390/app9050907 |