Loading…
Aerodynamic measures of patients with tracheostomy capping before and after decannulation
Background Gradually stepped decannulation, such as capping with fenestrated tubes or tube downsizing, is likely to prolong the decannulation process. The purpose of the study is to determine the differences in laryngeal aerodynamic measures, expiratory peak flow, and dyspnea index when breathing th...
Saved in:
Published in: | The Egyptian journal of otolaryngology 2022-12, Vol.38 (1), p.1-8, Article 7 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c450t-9872a764ffcb4801d22137ab1b84fdf2b3fe5f2ca3f2407c98a3f7c31e4c0dcc3 |
container_end_page | 8 |
container_issue | 1 |
container_start_page | 1 |
container_title | The Egyptian journal of otolaryngology |
container_volume | 38 |
creator | Youssef, Gamal Abdulla, Kamal M. Khalil, Sahar S. |
description | Background
Gradually stepped decannulation, such as capping with fenestrated tubes or tube downsizing, is likely to prolong the decannulation process. The purpose of the study is to determine the differences in laryngeal aerodynamic measures, expiratory peak flow, and dyspnea index when breathing through the upper airway before and after decannulation. The study recruited sixteen adult patients with a tracheostomy who were fit for decannulation. Measurement of peak flow rate, aerodynamic measures, and dyspnea index has been done at two settings: first during capping and second after decannulation by 2 h using finger support to close the stoma and prevent air leak.
Results
Changes in outcome measures after decannulation revealed a significant increase in peak flow rate, vital capacity, maximum phonation, and phonatory speech pressure level; the glottal resistance significantly decreased after decannulation. The dyspnea severity index scores improved from 22.35 during capping to 13.37 after decannulation.
Conclusions
The results of our study showed that tracheostomy tube capping causes a significant reduction in peak flow and aerodynamic measures which improved after tracheostomy decannulation. |
doi_str_mv | 10.1186/s43163-022-00198-x |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_2f5d03e7ad524f3ab3acd4f8fe013e35</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A690085549</galeid><doaj_id>oai_doaj_org_article_2f5d03e7ad524f3ab3acd4f8fe013e35</doaj_id><sourcerecordid>A690085549</sourcerecordid><originalsourceid>FETCH-LOGICAL-c450t-9872a764ffcb4801d22137ab1b84fdf2b3fe5f2ca3f2407c98a3f7c31e4c0dcc3</originalsourceid><addsrcrecordid>eNp9kUtrGzEUhYfSQE2SP5CVoNDdJHp6NEsT-ggEukkXXYk70pUtMyMZaUzjf185U0oCpdJC4nK-A_ecprlh9JYxvb4rUrC1aCnnLaWs1-3zu2bFaU9brUT_vlkxynirVCc_NNel7Gk9naRcsFXzc4M5uVOEKVgyIZRjxkKSJweYA8a5kF9h3pE5g91hKnOaTsTC4RDilgzoU0YC0RHwM2bi0EKMx7GiKV41Fx7Ggtd_3svmx5fPT_ff2sfvXx_uN4-tlYrOba87Dt1aem8HqSlznDPRwcAGLb3zfBAelecWhOeSdrbX9ddZwVBa6qwVl83D4usS7M0hhwnyySQI5mWQ8tZAnoMd0XCvHBXYgVNcegGDAOuk1x4pEyhU9fq4eG2hykP06bz4FIo1m3VPqVZK9lV1-w9VvQ5riimiD3X-Bvj0CtghjPOupPF4jqm8FfJFaHMqJaP_uw-j5ty1Wbo2tWvz0rV5rpBYoFLFcYvZ7NMxx5r5_6jf3nms8Q</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Aerodynamic measures of patients with tracheostomy capping before and after decannulation</title><source>Publicly Available Content Database</source><source>Springer Nature - SpringerLink Journals - Fully Open Access</source><creator>Youssef, Gamal ; Abdulla, Kamal M. ; Khalil, Sahar S.</creator><creatorcontrib>Youssef, Gamal ; Abdulla, Kamal M. ; Khalil, Sahar S.</creatorcontrib><description>Background
Gradually stepped decannulation, such as capping with fenestrated tubes or tube downsizing, is likely to prolong the decannulation process. The purpose of the study is to determine the differences in laryngeal aerodynamic measures, expiratory peak flow, and dyspnea index when breathing through the upper airway before and after decannulation. The study recruited sixteen adult patients with a tracheostomy who were fit for decannulation. Measurement of peak flow rate, aerodynamic measures, and dyspnea index has been done at two settings: first during capping and second after decannulation by 2 h using finger support to close the stoma and prevent air leak.
Results
Changes in outcome measures after decannulation revealed a significant increase in peak flow rate, vital capacity, maximum phonation, and phonatory speech pressure level; the glottal resistance significantly decreased after decannulation. The dyspnea severity index scores improved from 22.35 during capping to 13.37 after decannulation.
Conclusions
The results of our study showed that tracheostomy tube capping causes a significant reduction in peak flow and aerodynamic measures which improved after tracheostomy decannulation.</description><identifier>ISSN: 1012-5574</identifier><identifier>EISSN: 2090-8539</identifier><identifier>DOI: 10.1186/s43163-022-00198-x</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Aerodynamic ; Capping ; Decannulation ; Downsizing ; Measurement ; Medical research ; Medicine ; Medicine & Public Health ; Medicine, Experimental ; Original Article ; Surgery ; Tracheostomy</subject><ispartof>The Egyptian journal of otolaryngology, 2022-12, Vol.38 (1), p.1-8, Article 7</ispartof><rights>The Author(s) 2022</rights><rights>COPYRIGHT 2022 Springer</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c450t-9872a764ffcb4801d22137ab1b84fdf2b3fe5f2ca3f2407c98a3f7c31e4c0dcc3</cites><orcidid>0000-0002-2352-3395</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Youssef, Gamal</creatorcontrib><creatorcontrib>Abdulla, Kamal M.</creatorcontrib><creatorcontrib>Khalil, Sahar S.</creatorcontrib><title>Aerodynamic measures of patients with tracheostomy capping before and after decannulation</title><title>The Egyptian journal of otolaryngology</title><addtitle>Egypt J Otolaryngol</addtitle><description>Background
Gradually stepped decannulation, such as capping with fenestrated tubes or tube downsizing, is likely to prolong the decannulation process. The purpose of the study is to determine the differences in laryngeal aerodynamic measures, expiratory peak flow, and dyspnea index when breathing through the upper airway before and after decannulation. The study recruited sixteen adult patients with a tracheostomy who were fit for decannulation. Measurement of peak flow rate, aerodynamic measures, and dyspnea index has been done at two settings: first during capping and second after decannulation by 2 h using finger support to close the stoma and prevent air leak.
Results
Changes in outcome measures after decannulation revealed a significant increase in peak flow rate, vital capacity, maximum phonation, and phonatory speech pressure level; the glottal resistance significantly decreased after decannulation. The dyspnea severity index scores improved from 22.35 during capping to 13.37 after decannulation.
Conclusions
The results of our study showed that tracheostomy tube capping causes a significant reduction in peak flow and aerodynamic measures which improved after tracheostomy decannulation.</description><subject>Aerodynamic</subject><subject>Capping</subject><subject>Decannulation</subject><subject>Downsizing</subject><subject>Measurement</subject><subject>Medical research</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Medicine, Experimental</subject><subject>Original Article</subject><subject>Surgery</subject><subject>Tracheostomy</subject><issn>1012-5574</issn><issn>2090-8539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kUtrGzEUhYfSQE2SP5CVoNDdJHp6NEsT-ggEukkXXYk70pUtMyMZaUzjf185U0oCpdJC4nK-A_ecprlh9JYxvb4rUrC1aCnnLaWs1-3zu2bFaU9brUT_vlkxynirVCc_NNel7Gk9naRcsFXzc4M5uVOEKVgyIZRjxkKSJweYA8a5kF9h3pE5g91hKnOaTsTC4RDilgzoU0YC0RHwM2bi0EKMx7GiKV41Fx7Ggtd_3svmx5fPT_ff2sfvXx_uN4-tlYrOba87Dt1aem8HqSlznDPRwcAGLb3zfBAelecWhOeSdrbX9ddZwVBa6qwVl83D4usS7M0hhwnyySQI5mWQ8tZAnoMd0XCvHBXYgVNcegGDAOuk1x4pEyhU9fq4eG2hykP06bz4FIo1m3VPqVZK9lV1-w9VvQ5riimiD3X-Bvj0CtghjPOupPF4jqm8FfJFaHMqJaP_uw-j5ty1Wbo2tWvz0rV5rpBYoFLFcYvZ7NMxx5r5_6jf3nms8Q</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>Youssef, Gamal</creator><creator>Abdulla, Kamal M.</creator><creator>Khalil, Sahar S.</creator><general>Springer Berlin Heidelberg</general><general>Springer</general><general>SpringerOpen</general><scope>C6C</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-2352-3395</orcidid></search><sort><creationdate>20221201</creationdate><title>Aerodynamic measures of patients with tracheostomy capping before and after decannulation</title><author>Youssef, Gamal ; Abdulla, Kamal M. ; Khalil, Sahar S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c450t-9872a764ffcb4801d22137ab1b84fdf2b3fe5f2ca3f2407c98a3f7c31e4c0dcc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Aerodynamic</topic><topic>Capping</topic><topic>Decannulation</topic><topic>Downsizing</topic><topic>Measurement</topic><topic>Medical research</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Medicine, Experimental</topic><topic>Original Article</topic><topic>Surgery</topic><topic>Tracheostomy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Youssef, Gamal</creatorcontrib><creatorcontrib>Abdulla, Kamal M.</creatorcontrib><creatorcontrib>Khalil, Sahar S.</creatorcontrib><collection>SpringerOpen</collection><collection>CrossRef</collection><collection>DOAJÂ Directory of Open Access Journals</collection><jtitle>The Egyptian journal of otolaryngology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Youssef, Gamal</au><au>Abdulla, Kamal M.</au><au>Khalil, Sahar S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Aerodynamic measures of patients with tracheostomy capping before and after decannulation</atitle><jtitle>The Egyptian journal of otolaryngology</jtitle><stitle>Egypt J Otolaryngol</stitle><date>2022-12-01</date><risdate>2022</risdate><volume>38</volume><issue>1</issue><spage>1</spage><epage>8</epage><pages>1-8</pages><artnum>7</artnum><issn>1012-5574</issn><eissn>2090-8539</eissn><abstract>Background
Gradually stepped decannulation, such as capping with fenestrated tubes or tube downsizing, is likely to prolong the decannulation process. The purpose of the study is to determine the differences in laryngeal aerodynamic measures, expiratory peak flow, and dyspnea index when breathing through the upper airway before and after decannulation. The study recruited sixteen adult patients with a tracheostomy who were fit for decannulation. Measurement of peak flow rate, aerodynamic measures, and dyspnea index has been done at two settings: first during capping and second after decannulation by 2 h using finger support to close the stoma and prevent air leak.
Results
Changes in outcome measures after decannulation revealed a significant increase in peak flow rate, vital capacity, maximum phonation, and phonatory speech pressure level; the glottal resistance significantly decreased after decannulation. The dyspnea severity index scores improved from 22.35 during capping to 13.37 after decannulation.
Conclusions
The results of our study showed that tracheostomy tube capping causes a significant reduction in peak flow and aerodynamic measures which improved after tracheostomy decannulation.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><doi>10.1186/s43163-022-00198-x</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-2352-3395</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1012-5574 |
ispartof | The Egyptian journal of otolaryngology, 2022-12, Vol.38 (1), p.1-8, Article 7 |
issn | 1012-5574 2090-8539 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_2f5d03e7ad524f3ab3acd4f8fe013e35 |
source | Publicly Available Content Database; Springer Nature - SpringerLink Journals - Fully Open Access |
subjects | Aerodynamic Capping Decannulation Downsizing Measurement Medical research Medicine Medicine & Public Health Medicine, Experimental Original Article Surgery Tracheostomy |
title | Aerodynamic measures of patients with tracheostomy capping before and after decannulation |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T18%3A18%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Aerodynamic%20measures%20of%20patients%20with%20tracheostomy%20capping%20before%20and%20after%20decannulation&rft.jtitle=The%20Egyptian%20journal%20of%20otolaryngology&rft.au=Youssef,%20Gamal&rft.date=2022-12-01&rft.volume=38&rft.issue=1&rft.spage=1&rft.epage=8&rft.pages=1-8&rft.artnum=7&rft.issn=1012-5574&rft.eissn=2090-8539&rft_id=info:doi/10.1186/s43163-022-00198-x&rft_dat=%3Cgale_doaj_%3EA690085549%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c450t-9872a764ffcb4801d22137ab1b84fdf2b3fe5f2ca3f2407c98a3f7c31e4c0dcc3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A690085549&rfr_iscdi=true |