Installation of potable water supply and heat supply at base of subsoil water
Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow r...
Saved in:
Published in: | Renewable energy and environmental sustainability 2016, Vol.1, p.43 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Removal of groundwater with further use of it for potable water supply and heat supply with the use of heat pump is an important problem. A new revolutionary approach to the decision of energy and water saving that provides rational accommodation of groundwater boreholes ensuring the required flow rate of water through the heat pump evaporator with simultaneously high intensity of heat exchange process is proposed. The method of calculation which allows determining the necessary depth of borehole, quantity of boreholes, in consideration of flow rate and temperature of subsoil water determining capacity of heat pump installation is worked out. |
---|---|
ISSN: | 2493-9439 2493-9439 |
DOI: | 10.1051/rees/2016046 |