Loading…
Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution
The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasou...
Saved in:
Published in: | Brazilian journal of anesthesiology (Elsevier) 2017-07, Vol.67 (4), p.376-382 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83 |
---|---|
cites | cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83 |
container_end_page | 382 |
container_issue | 4 |
container_start_page | 376 |
container_title | Brazilian journal of anesthesiology (Elsevier) |
container_volume | 67 |
creator | Bisinotto, Flora Margarida Barra Naves, Aline de Araújo Lima, Hellen Moreira de Peixoto, Ana Cristina Abdu Maia, Gisele Caetano Junior, Paulo Pacheco Resende Martins, Laura Bisinotto Silveira, Luciano A. Matias da |
description | The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment.
Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant.
Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution.
As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica.
Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p0,05). Cinco voluntários (6,2 |
doi_str_mv | 10.1016/j.bjane.2017.03.001 |
format | article |
fullrecord | <record><control><sourceid>scielo_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0034_70942017000400376</scielo_id><els_id>S0104001417300192</els_id><doaj_id>oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65</doaj_id><sourcerecordid>S0034_70942017000400376</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</originalsourceid><addsrcrecordid>eNp9kcFq3DAQhk1JICHJE-TiF1hX8siyfeihhLYJBHpIchaz0swi41hFkhf69pV3Q-mpJ_36me-fYaaq7qVopJD689TsJ1yoaYXsGwGNEPJTdS2kULsi1cU_-qq6S2kSRUoYoRXXlX9LVAeu1zlHTGFdXM0h1gdMOXpbH8O8vlNNR5xXzD4sNXKmWPvlQOn0L6zzzBRpyR_laTN9CjksJSIVb6u8rS4Z50R3H-9N9fb92-vD4-7554-nh6_POwsD5B0OenDMVoJrR0U9kwRi7rFj0rRvtew6BOxsx06AHKV17dByZ0E7pXGAm-rpnOsCTuZX9O8Yf5uA3pyMEA8GY_Z2JgOSQPfcM0tSdmCEVjmmcWxB8F53Jas5ZyXraQ5mCmtcyvDmRQhQphej2rZeFqqK0esCwBmwMaQUif8OIIXZrmUmc7qW2TgjwJRbFOrLmaKyl6OnaLZ-iyXnI9lcBvf_5f8AsJWehQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><source>BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS</source><source>Elsevier ScienceDirect Journals</source><source>SciELO</source><creator>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</creator><creatorcontrib>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</creatorcontrib><description>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment.
Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value<0.05 was considered significant).
There was no difference in quantitative variables at measurement times (p>0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant.
Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution.
As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica.
Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p<0,05.
Não houve diferença nas variáveis quantitativas nos três momentos estudados (p>0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística.
O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</description><identifier>ISSN: 0104-0014</identifier><identifier>ISSN: 1806-907X</identifier><identifier>EISSN: 0104-0014</identifier><identifier>DOI: 10.1016/j.bjane.2017.03.001</identifier><language>eng</language><publisher>Elsevier Editora Ltda</publisher><subject>ANESTHESIOLOGY ; Bronchoaspiration ; Broncoaspiração ; Gastric ultrasound ; Jejum pré-operatório ; Preoperative fasting ; Ultrassonografia gástrica</subject><ispartof>Brazilian journal of anesthesiology (Elsevier), 2017-07, Vol.67 (4), p.376-382</ispartof><rights>2016 Sociedade Brasileira de Anestesiologia</rights><rights>This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</citedby><cites>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0104001417300192$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,776,780,881,3536,24131,27903,27904,45759</link.rule.ids></links><search><creatorcontrib>Bisinotto, Flora Margarida Barra</creatorcontrib><creatorcontrib>Naves, Aline de Araújo</creatorcontrib><creatorcontrib>Lima, Hellen Moreira de</creatorcontrib><creatorcontrib>Peixoto, Ana Cristina Abdu</creatorcontrib><creatorcontrib>Maia, Gisele Caetano</creatorcontrib><creatorcontrib>Junior, Paulo Pacheco Resende</creatorcontrib><creatorcontrib>Martins, Laura Bisinotto</creatorcontrib><creatorcontrib>Silveira, Luciano A. Matias da</creatorcontrib><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><title>Brazilian journal of anesthesiology (Elsevier)</title><addtitle>Rev. Bras. Anestesiol</addtitle><description>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment.
Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value<0.05 was considered significant).
There was no difference in quantitative variables at measurement times (p>0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant.
Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution.
As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica.
Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p<0,05.
Não houve diferença nas variáveis quantitativas nos três momentos estudados (p>0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística.
O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</description><subject>ANESTHESIOLOGY</subject><subject>Bronchoaspiration</subject><subject>Broncoaspiração</subject><subject>Gastric ultrasound</subject><subject>Jejum pré-operatório</subject><subject>Preoperative fasting</subject><subject>Ultrassonografia gástrica</subject><issn>0104-0014</issn><issn>1806-907X</issn><issn>0104-0014</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kcFq3DAQhk1JICHJE-TiF1hX8siyfeihhLYJBHpIchaz0swi41hFkhf69pV3Q-mpJ_36me-fYaaq7qVopJD689TsJ1yoaYXsGwGNEPJTdS2kULsi1cU_-qq6S2kSRUoYoRXXlX9LVAeu1zlHTGFdXM0h1gdMOXpbH8O8vlNNR5xXzD4sNXKmWPvlQOn0L6zzzBRpyR_laTN9CjksJSIVb6u8rS4Z50R3H-9N9fb92-vD4-7554-nh6_POwsD5B0OenDMVoJrR0U9kwRi7rFj0rRvtew6BOxsx06AHKV17dByZ0E7pXGAm-rpnOsCTuZX9O8Yf5uA3pyMEA8GY_Z2JgOSQPfcM0tSdmCEVjmmcWxB8F53Jas5ZyXraQ5mCmtcyvDmRQhQphej2rZeFqqK0esCwBmwMaQUif8OIIXZrmUmc7qW2TgjwJRbFOrLmaKyl6OnaLZ-iyXnI9lcBvf_5f8AsJWehQ</recordid><startdate>201707</startdate><enddate>201707</enddate><creator>Bisinotto, Flora Margarida Barra</creator><creator>Naves, Aline de Araújo</creator><creator>Lima, Hellen Moreira de</creator><creator>Peixoto, Ana Cristina Abdu</creator><creator>Maia, Gisele Caetano</creator><creator>Junior, Paulo Pacheco Resende</creator><creator>Martins, Laura Bisinotto</creator><creator>Silveira, Luciano A. Matias da</creator><general>Elsevier Editora Ltda</general><general>Sociedade Brasileira de Anestesiologia</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope><scope>DOA</scope></search><sort><creationdate>201707</creationdate><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><author>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>ANESTHESIOLOGY</topic><topic>Bronchoaspiration</topic><topic>Broncoaspiração</topic><topic>Gastric ultrasound</topic><topic>Jejum pré-operatório</topic><topic>Preoperative fasting</topic><topic>Ultrassonografia gástrica</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bisinotto, Flora Margarida Barra</creatorcontrib><creatorcontrib>Naves, Aline de Araújo</creatorcontrib><creatorcontrib>Lima, Hellen Moreira de</creatorcontrib><creatorcontrib>Peixoto, Ana Cristina Abdu</creatorcontrib><creatorcontrib>Maia, Gisele Caetano</creatorcontrib><creatorcontrib>Junior, Paulo Pacheco Resende</creatorcontrib><creatorcontrib>Martins, Laura Bisinotto</creatorcontrib><creatorcontrib>Silveira, Luciano A. Matias da</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>SciELO</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Brazilian journal of anesthesiology (Elsevier)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bisinotto, Flora Margarida Barra</au><au>Naves, Aline de Araújo</au><au>Lima, Hellen Moreira de</au><au>Peixoto, Ana Cristina Abdu</au><au>Maia, Gisele Caetano</au><au>Junior, Paulo Pacheco Resende</au><au>Martins, Laura Bisinotto</au><au>Silveira, Luciano A. Matias da</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</atitle><jtitle>Brazilian journal of anesthesiology (Elsevier)</jtitle><addtitle>Rev. Bras. Anestesiol</addtitle><date>2017-07</date><risdate>2017</risdate><volume>67</volume><issue>4</issue><spage>376</spage><epage>382</epage><pages>376-382</pages><issn>0104-0014</issn><issn>1806-907X</issn><eissn>0104-0014</eissn><abstract>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment.
Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value<0.05 was considered significant).
There was no difference in quantitative variables at measurement times (p>0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant.
Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution.
As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica.
Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p<0,05.
Não houve diferença nas variáveis quantitativas nos três momentos estudados (p>0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística.
O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</abstract><pub>Elsevier Editora Ltda</pub><doi>10.1016/j.bjane.2017.03.001</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0104-0014 |
ispartof | Brazilian journal of anesthesiology (Elsevier), 2017-07, Vol.67 (4), p.376-382 |
issn | 0104-0014 1806-907X 0104-0014 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65 |
source | BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS; Elsevier ScienceDirect Journals; SciELO |
subjects | ANESTHESIOLOGY Bronchoaspiration Broncoaspiração Gastric ultrasound Jejum pré-operatório Preoperative fasting Ultrassonografia gástrica |
title | Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T17%3A37%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20ultrasound%20for%20gastric%20volume%20evaluation%20after%20ingestion%20of%20different%20volumes%20of%20isotonic%20solution&rft.jtitle=Brazilian%20journal%20of%20anesthesiology%20(Elsevier)&rft.au=Bisinotto,%20Flora%20Margarida%20Barra&rft.date=2017-07&rft.volume=67&rft.issue=4&rft.spage=376&rft.epage=382&rft.pages=376-382&rft.issn=0104-0014&rft.eissn=0104-0014&rft_id=info:doi/10.1016/j.bjane.2017.03.001&rft_dat=%3Cscielo_doaj_%3ES0034_70942017000400376%3C/scielo_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0034_70942017000400376&rfr_iscdi=true |