Loading…

Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution

The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasou...

Full description

Saved in:
Bibliographic Details
Published in:Brazilian journal of anesthesiology (Elsevier) 2017-07, Vol.67 (4), p.376-382
Main Authors: Bisinotto, Flora Margarida Barra, Naves, Aline de Araújo, Lima, Hellen Moreira de, Peixoto, Ana Cristina Abdu, Maia, Gisele Caetano, Junior, Paulo Pacheco Resende, Martins, Laura Bisinotto, Silveira, Luciano A. Matias da
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83
cites cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83
container_end_page 382
container_issue 4
container_start_page 376
container_title Brazilian journal of anesthesiology (Elsevier)
container_volume 67
creator Bisinotto, Flora Margarida Barra
Naves, Aline de Araújo
Lima, Hellen Moreira de
Peixoto, Ana Cristina Abdu
Maia, Gisele Caetano
Junior, Paulo Pacheco Resende
Martins, Laura Bisinotto
Silveira, Luciano A. Matias da
description The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment. Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant. Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution. As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica. Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p0,05). Cinco voluntários (6,2
doi_str_mv 10.1016/j.bjane.2017.03.001
format article
fullrecord <record><control><sourceid>scielo_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S0034_70942017000400376</scielo_id><els_id>S0104001417300192</els_id><doaj_id>oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65</doaj_id><sourcerecordid>S0034_70942017000400376</sourcerecordid><originalsourceid>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</originalsourceid><addsrcrecordid>eNp9kcFq3DAQhk1JICHJE-TiF1hX8siyfeihhLYJBHpIchaz0swi41hFkhf69pV3Q-mpJ_36me-fYaaq7qVopJD689TsJ1yoaYXsGwGNEPJTdS2kULsi1cU_-qq6S2kSRUoYoRXXlX9LVAeu1zlHTGFdXM0h1gdMOXpbH8O8vlNNR5xXzD4sNXKmWPvlQOn0L6zzzBRpyR_laTN9CjksJSIVb6u8rS4Z50R3H-9N9fb92-vD4-7554-nh6_POwsD5B0OenDMVoJrR0U9kwRi7rFj0rRvtew6BOxsx06AHKV17dByZ0E7pXGAm-rpnOsCTuZX9O8Yf5uA3pyMEA8GY_Z2JgOSQPfcM0tSdmCEVjmmcWxB8F53Jas5ZyXraQ5mCmtcyvDmRQhQphej2rZeFqqK0esCwBmwMaQUif8OIIXZrmUmc7qW2TgjwJRbFOrLmaKyl6OnaLZ-iyXnI9lcBvf_5f8AsJWehQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><source>BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS</source><source>Elsevier ScienceDirect Journals</source><source>SciELO</source><creator>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</creator><creatorcontrib>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</creatorcontrib><description>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment. Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value&lt;0.05 was considered significant). There was no difference in quantitative variables at measurement times (p&gt;0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant. Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution. As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica. Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p&lt;0,05. Não houve diferença nas variáveis quantitativas nos três momentos estudados (p&gt;0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística. O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</description><identifier>ISSN: 0104-0014</identifier><identifier>ISSN: 1806-907X</identifier><identifier>EISSN: 0104-0014</identifier><identifier>DOI: 10.1016/j.bjane.2017.03.001</identifier><language>eng</language><publisher>Elsevier Editora Ltda</publisher><subject>ANESTHESIOLOGY ; Bronchoaspiration ; Broncoaspiração ; Gastric ultrasound ; Jejum pré-operatório ; Preoperative fasting ; Ultrassonografia gástrica</subject><ispartof>Brazilian journal of anesthesiology (Elsevier), 2017-07, Vol.67 (4), p.376-382</ispartof><rights>2016 Sociedade Brasileira de Anestesiologia</rights><rights>This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</citedby><cites>FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0104001417300192$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,776,780,881,3536,24131,27903,27904,45759</link.rule.ids></links><search><creatorcontrib>Bisinotto, Flora Margarida Barra</creatorcontrib><creatorcontrib>Naves, Aline de Araújo</creatorcontrib><creatorcontrib>Lima, Hellen Moreira de</creatorcontrib><creatorcontrib>Peixoto, Ana Cristina Abdu</creatorcontrib><creatorcontrib>Maia, Gisele Caetano</creatorcontrib><creatorcontrib>Junior, Paulo Pacheco Resende</creatorcontrib><creatorcontrib>Martins, Laura Bisinotto</creatorcontrib><creatorcontrib>Silveira, Luciano A. Matias da</creatorcontrib><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><title>Brazilian journal of anesthesiology (Elsevier)</title><addtitle>Rev. Bras. Anestesiol</addtitle><description>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment. Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value&lt;0.05 was considered significant). There was no difference in quantitative variables at measurement times (p&gt;0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant. Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution. As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica. Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p&lt;0,05. Não houve diferença nas variáveis quantitativas nos três momentos estudados (p&gt;0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística. O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</description><subject>ANESTHESIOLOGY</subject><subject>Bronchoaspiration</subject><subject>Broncoaspiração</subject><subject>Gastric ultrasound</subject><subject>Jejum pré-operatório</subject><subject>Preoperative fasting</subject><subject>Ultrassonografia gástrica</subject><issn>0104-0014</issn><issn>1806-907X</issn><issn>0104-0014</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kcFq3DAQhk1JICHJE-TiF1hX8siyfeihhLYJBHpIchaz0swi41hFkhf69pV3Q-mpJ_36me-fYaaq7qVopJD689TsJ1yoaYXsGwGNEPJTdS2kULsi1cU_-qq6S2kSRUoYoRXXlX9LVAeu1zlHTGFdXM0h1gdMOXpbH8O8vlNNR5xXzD4sNXKmWPvlQOn0L6zzzBRpyR_laTN9CjksJSIVb6u8rS4Z50R3H-9N9fb92-vD4-7554-nh6_POwsD5B0OenDMVoJrR0U9kwRi7rFj0rRvtew6BOxsx06AHKV17dByZ0E7pXGAm-rpnOsCTuZX9O8Yf5uA3pyMEA8GY_Z2JgOSQPfcM0tSdmCEVjmmcWxB8F53Jas5ZyXraQ5mCmtcyvDmRQhQphej2rZeFqqK0esCwBmwMaQUif8OIIXZrmUmc7qW2TgjwJRbFOrLmaKyl6OnaLZ-iyXnI9lcBvf_5f8AsJWehQ</recordid><startdate>201707</startdate><enddate>201707</enddate><creator>Bisinotto, Flora Margarida Barra</creator><creator>Naves, Aline de Araújo</creator><creator>Lima, Hellen Moreira de</creator><creator>Peixoto, Ana Cristina Abdu</creator><creator>Maia, Gisele Caetano</creator><creator>Junior, Paulo Pacheco Resende</creator><creator>Martins, Laura Bisinotto</creator><creator>Silveira, Luciano A. Matias da</creator><general>Elsevier Editora Ltda</general><general>Sociedade Brasileira de Anestesiologia</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope><scope>DOA</scope></search><sort><creationdate>201707</creationdate><title>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</title><author>Bisinotto, Flora Margarida Barra ; Naves, Aline de Araújo ; Lima, Hellen Moreira de ; Peixoto, Ana Cristina Abdu ; Maia, Gisele Caetano ; Junior, Paulo Pacheco Resende ; Martins, Laura Bisinotto ; Silveira, Luciano A. Matias da</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>ANESTHESIOLOGY</topic><topic>Bronchoaspiration</topic><topic>Broncoaspiração</topic><topic>Gastric ultrasound</topic><topic>Jejum pré-operatório</topic><topic>Preoperative fasting</topic><topic>Ultrassonografia gástrica</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bisinotto, Flora Margarida Barra</creatorcontrib><creatorcontrib>Naves, Aline de Araújo</creatorcontrib><creatorcontrib>Lima, Hellen Moreira de</creatorcontrib><creatorcontrib>Peixoto, Ana Cristina Abdu</creatorcontrib><creatorcontrib>Maia, Gisele Caetano</creatorcontrib><creatorcontrib>Junior, Paulo Pacheco Resende</creatorcontrib><creatorcontrib>Martins, Laura Bisinotto</creatorcontrib><creatorcontrib>Silveira, Luciano A. Matias da</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>SciELO</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Brazilian journal of anesthesiology (Elsevier)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bisinotto, Flora Margarida Barra</au><au>Naves, Aline de Araújo</au><au>Lima, Hellen Moreira de</au><au>Peixoto, Ana Cristina Abdu</au><au>Maia, Gisele Caetano</au><au>Junior, Paulo Pacheco Resende</au><au>Martins, Laura Bisinotto</au><au>Silveira, Luciano A. Matias da</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution</atitle><jtitle>Brazilian journal of anesthesiology (Elsevier)</jtitle><addtitle>Rev. Bras. Anestesiol</addtitle><date>2017-07</date><risdate>2017</risdate><volume>67</volume><issue>4</issue><spage>376</spage><epage>382</epage><pages>376-382</pages><issn>0104-0014</issn><issn>1806-907X</issn><eissn>0104-0014</eissn><abstract>The current preoperative fasting guidelines allow fluid intake up to 2h before surgery. The aim of this study was to evaluate the gastric volume of volunteers after an overnight fast and compare it with the gastric volume 2h after ingestion of 200 and 500mL of isotonic solution, by means of ultrasound assessment. Eighty volunteers underwent gastric ultrasound at three times: after 8h of fasting; 2h after ingestion of 200mL isotonic saline, followed by the first scan; and on another day, 2h after ingestion of 500mL of the same solution after an overnight fast. The evaluation was quantitative (antrum area and gastric volume, and the ratio of participants’ gastric volume/weight) and qualitative (absence or presence of gastric contents on right lateral decubitus and supine positions. A p-value&lt;0.05 was considered significant). There was no difference in quantitative variables at measurement times (p&gt;0.05). Five volunteers (6.25%) had a volume/weight over 1.5mLkg−1 at fasting and 2h after ingestion of 200mL and 6 (7.5%) after 500mL. Qualitatively, the presence of gastric fluid occurred in more volunteers after fluid ingestion, especially 500mL (18.7%), although not statistically significant. Ultrasound assessment of gastric volume showed no significant difference, both qualitative and quantitative, 2h after ingestion of 200mL or 500mL of isotonic solution compared to fasting, although gastric fluid content has been identified in more volunteers, especially after ingestion of 500mL isotonic solution. As diretrizes recentes de jejum pré-operatório permitem a ingestão de líquidos até 2 horas antes da cirurgia. O objetivo do presente estudo foi, por meio de ultrassonografia gástrica, avaliar o volume gástrico de voluntários após jejum noturno e comparar com o volume gástrico duas horas após a ingestão de 200 e 500ml de solução isotônica. Foram submetidos à ultrassonografia gástrica 80 voluntários em três momentos: após jejum de 8horas; 2horas após a ingestão de 200ml de solução isotônica, seguida do primeiro exame; e, em outro dia, 2horas após a ingestão de 500ml da mesma solução, após jejum noturno. A avaliação foi quantitativa (área do antro e volume gástricos e relação volume gástrico/peso dos participantes) e qualitativa, pela ausência ou presença de conteúdo gástrico nas posições de decúbito lateral direito e supina. Foi considerado significante p&lt;0,05. Não houve diferença nas variáveis quantitativas nos três momentos estudados (p&gt;0,05). Cinco voluntários (6,25%) apresentaram um volume/peso superior a 1,5ml.kg−1 em jejum e 2horas após a ingestão de 200ml e seis (7,5%) após 500ml. Qualitativamente, a presença de líquido gástrico ocorreu em mais voluntários após a ingestão de líquidos, principalmente de 500ml (18,7%), embora sem significância estatística. O volume gástrico pela ultrassonografia não apresenta diferença significativa tanto qualitativa quanto quantitativa, 2horas após a ingestão de 200ml ou de 500ml de solução isotônica em comparação com o jejum, embora conteúdo líquido gástrico tenha sido identificado em mais voluntários, principalmente após a ingestão de 500ml de solução isotônica.</abstract><pub>Elsevier Editora Ltda</pub><doi>10.1016/j.bjane.2017.03.001</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0104-0014
ispartof Brazilian journal of anesthesiology (Elsevier), 2017-07, Vol.67 (4), p.376-382
issn 0104-0014
1806-907X
0104-0014
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_31e367f7ff1e4c8fa324dfe99230fb65
source BACON - Elsevier - GLOBAL_SCIENCEDIRECT-OPENACCESS; Elsevier ScienceDirect Journals; SciELO
subjects ANESTHESIOLOGY
Bronchoaspiration
Broncoaspiração
Gastric ultrasound
Jejum pré-operatório
Preoperative fasting
Ultrassonografia gástrica
title Use of ultrasound for gastric volume evaluation after ingestion of different volumes of isotonic solution
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T17%3A37%3A17IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Use%20of%20ultrasound%20for%20gastric%20volume%20evaluation%20after%20ingestion%20of%20different%20volumes%20of%20isotonic%20solution&rft.jtitle=Brazilian%20journal%20of%20anesthesiology%20(Elsevier)&rft.au=Bisinotto,%20Flora%20Margarida%20Barra&rft.date=2017-07&rft.volume=67&rft.issue=4&rft.spage=376&rft.epage=382&rft.pages=376-382&rft.issn=0104-0014&rft.eissn=0104-0014&rft_id=info:doi/10.1016/j.bjane.2017.03.001&rft_dat=%3Cscielo_doaj_%3ES0034_70942017000400376%3C/scielo_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c383t-a868dffc13d294e7fe13eff7a5fe6eb26155a3a5c5fd03191cd282f5c36d46a83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S0034_70942017000400376&rfr_iscdi=true