Loading…

Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker

In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clini...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in bioengineering and biotechnology 2023-03, Vol.11, p.1153987-1153987
Main Authors: Wang, Mengyue, Gao, Feng, Ni, Shoujie, Song, Yanan, Wang, Cai, Li, Qian, Zhao, Peng
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3
cites cdi_FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3
container_end_page 1153987
container_issue
container_start_page 1153987
container_title Frontiers in bioengineering and biotechnology
container_volume 11
creator Wang, Mengyue
Gao, Feng
Ni, Shoujie
Song, Yanan
Wang, Cai
Li, Qian
Zhao, Peng
description In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research. In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor. Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10 ng/mL to 10 ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference. The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.
doi_str_mv 10.3389/fbioe.2023.1153987
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_31f0038027214dc0919e55418f0fb57f</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_31f0038027214dc0919e55418f0fb57f</doaj_id><sourcerecordid>2791706540</sourcerecordid><originalsourceid>FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3</originalsourceid><addsrcrecordid>eNpVkUtv1DAQgC0EotXSP8AB-cglix9xHJ8QqgpUqsQFzpYf441LYhc7QeLf1-0uVXuy5Zn5ZsYfQu8p2XM-qk_Bxgx7RhjfUyq4GuUrdM6YGrqejuL1s_sZuqj1lhBCmZBiZG_RGR-UJANl5yhczeDWkt0ES3RmxnFZtpQrpJoLtqaCxznhQ559t04xp5gAhxbysLbC9oBzwHWzphg3pRw9bqRcymQOgNuMiym_obxDb4KZK1yczh369fXq5-X37ubHt-vLLzed6we1dm0TGPzAKJWGBUmZYoPoCQTbB28UCURKoEMA23MYhaTKKmFMEIQLIGD5Dl0fuT6bW31XYmv_T2cT9eNDLgdtyhrdDJrTQAgfCZOM9t4RRRUI0T4skGCFDI31-ci62-wC3kFai5lfQF9GUpz0If_VtHGJaFJ26OOJUPKfDeqql1gdzLNJkLeqmVS0eWgbtlR2THUl11ogPPWhRD8I14_C9YNwfRLeij48n_Cp5L9efg-1gqlS</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2791706540</pqid></control><display><type>article</type><title>Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker</title><source>PubMed Central</source><creator>Wang, Mengyue ; Gao, Feng ; Ni, Shoujie ; Song, Yanan ; Wang, Cai ; Li, Qian ; Zhao, Peng</creator><creatorcontrib>Wang, Mengyue ; Gao, Feng ; Ni, Shoujie ; Song, Yanan ; Wang, Cai ; Li, Qian ; Zhao, Peng</creatorcontrib><description>In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research. In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor. Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10 ng/mL to 10 ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference. The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.</description><identifier>ISSN: 2296-4185</identifier><identifier>EISSN: 2296-4185</identifier><identifier>DOI: 10.3389/fbioe.2023.1153987</identifier><identifier>PMID: 36970612</identifier><language>eng</language><publisher>Switzerland: Frontiers Media S.A</publisher><subject>AuNP ; Bioengineering and Biotechnology ; IL-6 ; immunosensor ; SAH ; THI</subject><ispartof>Frontiers in bioengineering and biotechnology, 2023-03, Vol.11, p.1153987-1153987</ispartof><rights>Copyright © 2023 Wang, Gao, Ni, Song, Wang, Li and Zhao.</rights><rights>Copyright © 2023 Wang, Gao, Ni, Song, Wang, Li and Zhao. 2023 Wang, Gao, Ni, Song, Wang, Li and Zhao</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3</citedby><cites>FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10030515/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC10030515/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/36970612$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, Mengyue</creatorcontrib><creatorcontrib>Gao, Feng</creatorcontrib><creatorcontrib>Ni, Shoujie</creatorcontrib><creatorcontrib>Song, Yanan</creatorcontrib><creatorcontrib>Wang, Cai</creatorcontrib><creatorcontrib>Li, Qian</creatorcontrib><creatorcontrib>Zhao, Peng</creatorcontrib><title>Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker</title><title>Frontiers in bioengineering and biotechnology</title><addtitle>Front Bioeng Biotechnol</addtitle><description>In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research. In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor. Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10 ng/mL to 10 ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference. The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.</description><subject>AuNP</subject><subject>Bioengineering and Biotechnology</subject><subject>IL-6</subject><subject>immunosensor</subject><subject>SAH</subject><subject>THI</subject><issn>2296-4185</issn><issn>2296-4185</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkUtv1DAQgC0EotXSP8AB-cglix9xHJ8QqgpUqsQFzpYf441LYhc7QeLf1-0uVXuy5Zn5ZsYfQu8p2XM-qk_Bxgx7RhjfUyq4GuUrdM6YGrqejuL1s_sZuqj1lhBCmZBiZG_RGR-UJANl5yhczeDWkt0ES3RmxnFZtpQrpJoLtqaCxznhQ559t04xp5gAhxbysLbC9oBzwHWzphg3pRw9bqRcymQOgNuMiym_obxDb4KZK1yczh369fXq5-X37ubHt-vLLzed6we1dm0TGPzAKJWGBUmZYoPoCQTbB28UCURKoEMA23MYhaTKKmFMEIQLIGD5Dl0fuT6bW31XYmv_T2cT9eNDLgdtyhrdDJrTQAgfCZOM9t4RRRUI0T4skGCFDI31-ci62-wC3kFai5lfQF9GUpz0If_VtHGJaFJ26OOJUPKfDeqql1gdzLNJkLeqmVS0eWgbtlR2THUl11ogPPWhRD8I14_C9YNwfRLeij48n_Cp5L9efg-1gqlS</recordid><startdate>20230308</startdate><enddate>20230308</enddate><creator>Wang, Mengyue</creator><creator>Gao, Feng</creator><creator>Ni, Shoujie</creator><creator>Song, Yanan</creator><creator>Wang, Cai</creator><creator>Li, Qian</creator><creator>Zhao, Peng</creator><general>Frontiers Media S.A</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20230308</creationdate><title>Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker</title><author>Wang, Mengyue ; Gao, Feng ; Ni, Shoujie ; Song, Yanan ; Wang, Cai ; Li, Qian ; Zhao, Peng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>AuNP</topic><topic>Bioengineering and Biotechnology</topic><topic>IL-6</topic><topic>immunosensor</topic><topic>SAH</topic><topic>THI</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, Mengyue</creatorcontrib><creatorcontrib>Gao, Feng</creatorcontrib><creatorcontrib>Ni, Shoujie</creatorcontrib><creatorcontrib>Song, Yanan</creatorcontrib><creatorcontrib>Wang, Cai</creatorcontrib><creatorcontrib>Li, Qian</creatorcontrib><creatorcontrib>Zhao, Peng</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ: Directory of Open Access Journals</collection><jtitle>Frontiers in bioengineering and biotechnology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, Mengyue</au><au>Gao, Feng</au><au>Ni, Shoujie</au><au>Song, Yanan</au><au>Wang, Cai</au><au>Li, Qian</au><au>Zhao, Peng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker</atitle><jtitle>Frontiers in bioengineering and biotechnology</jtitle><addtitle>Front Bioeng Biotechnol</addtitle><date>2023-03-08</date><risdate>2023</risdate><volume>11</volume><spage>1153987</spage><epage>1153987</epage><pages>1153987-1153987</pages><issn>2296-4185</issn><eissn>2296-4185</eissn><abstract>In clinical work, the realization of an early diagnosis of Subarachnoid hemorrhage (SAH) is primarily based on conventional computed tomography (CT), MR angiography, transcranial Doppler (TCD) ultrasound, and neurological assessments. However, the association between imaging manifestations and clinical findings is insufficiently perfect, particularly in SAH patients in acute phases with a lower amount of blood. The establishment of a direct, rapid and ultra-sensitive detection method based on electrochemical biosensors has emerged as a new competitive challenge in disease biomarkers research. In this study, a novel free-labeled electrochemical immunosensor for rapidly and sensitively detecting IL-6 in subarachnoid hemorrhage (SAH) blood has been developed using Au nanospheres-thionine composites (AuNPs/THI) as the interface modified on the electrode. Then, we detected IL-6 in blood samples from SAH patients by (enzyme-linked immunosorbent assay) ELISA and electrochemical immunosensor. Under the best conditions, the developed electrochemical immunosensor exhibited a wide linear range from 10 ng/mL to 10 ng/mL with a low detection limit of 1.85 pg/mL. Furthermore, when the immunosensor was employed in the analysis of IL-6 in 100% serum, the results obtained by electrochemical immunoassay were consistent with those obtained by ELISA without suffering from other significant biological interference. The designed electrochemical immunosensor realizes the detection of IL-6 in actual serum samples with high accuracy and sensitivity, and could potentially become a promising technique for applications in the clinical diagnosis of SAH.</abstract><cop>Switzerland</cop><pub>Frontiers Media S.A</pub><pmid>36970612</pmid><doi>10.3389/fbioe.2023.1153987</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2296-4185
ispartof Frontiers in bioengineering and biotechnology, 2023-03, Vol.11, p.1153987-1153987
issn 2296-4185
2296-4185
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_31f0038027214dc0919e55418f0fb57f
source PubMed Central
subjects AuNP
Bioengineering and Biotechnology
IL-6
immunosensor
SAH
THI
title Electrochemical immunosensor based on gold-thionine for detection of subarachnoid hemorrhage biomarker
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T17%3A26%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemical%20immunosensor%20based%20on%20gold-thionine%20for%20detection%20of%20subarachnoid%20hemorrhage%20biomarker&rft.jtitle=Frontiers%20in%20bioengineering%20and%20biotechnology&rft.au=Wang,%20Mengyue&rft.date=2023-03-08&rft.volume=11&rft.spage=1153987&rft.epage=1153987&rft.pages=1153987-1153987&rft.issn=2296-4185&rft.eissn=2296-4185&rft_id=info:doi/10.3389/fbioe.2023.1153987&rft_dat=%3Cproquest_doaj_%3E2791706540%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c469t-115e6d62117a2f712926540efb4fda90f077e16feb43e85719b95aaf5035e0eb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2791706540&rft_id=info:pmid/36970612&rfr_iscdi=true