Loading…

Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria

The objective of the present study was to evaluate the quality and intensity of the tissue response to two synthetic hydroxyapatites implanted in critical defects in the skulls of rats. Sixty animals were divided into three experimental groups: I (control), II (HA-1 = HA with 28% crystallinity) and...

Full description

Saved in:
Bibliographic Details
Published in:Materials research (São Carlos, São Paulo, Brazil) São Paulo, Brazil), 2009-06, Vol.12 (2), p.245-251
Main Authors: Costa, Neusa Motta de Freitas, Melo, Bruno Raposo, Brito, Rosana Tavares, Fernandes, Gustavo Vicentis de Oliveira, Bernardo, Vagner Gonçalves, Fonseca, Eliene Carvalho, Conz, Marcio Baltazar, Soares, Glória Almeida, Granjeiro, José Mauro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03
cites cdi_FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03
container_end_page 251
container_issue 2
container_start_page 245
container_title Materials research (São Carlos, São Paulo, Brazil)
container_volume 12
creator Costa, Neusa Motta de Freitas
Melo, Bruno Raposo
Brito, Rosana Tavares
Fernandes, Gustavo Vicentis de Oliveira
Bernardo, Vagner Gonçalves
Fonseca, Eliene Carvalho
Conz, Marcio Baltazar
Soares, Glória Almeida
Granjeiro, José Mauro
description The objective of the present study was to evaluate the quality and intensity of the tissue response to two synthetic hydroxyapatites implanted in critical defects in the skulls of rats. Sixty animals were divided into three experimental groups: I (control), II (HA-1 = HA with 28% crystallinity) and III (HA-2 = HA with 70% crystallinity). They were sacrificed 1, 3, 6, and 9 months after implantation (n = 5 individuals per group/period). Histomorphometric analysis included i) counting of polymorphonuclear leucocytes, mast cells, macrophages and foreign body multinucleated giant cells stained with anti-lysozyme; ii) microvascular density stained with anti-Factor VIII and iii) degree of cell proliferation stained with anti-PCNA. There were no significant differences between the experimental groups in either the quality or quantity of cells in the inflammatory infiltrate, or the degree of angiogenesis and cell proliferation. We conclude that HA-1 and HA-2 are biocompatible and that the physico-chemical differences of these biomaterials did not affect cellular response.
doi_str_mv 10.1590/S1516-14392009000200022
format article
fullrecord <record><control><sourceid>scielo_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_38a16fb14a5a4c09b56811719047b70d</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><scielo_id>S1516_14392009000200022</scielo_id><doaj_id>oai_doaj_org_article_38a16fb14a5a4c09b56811719047b70d</doaj_id><sourcerecordid>S1516_14392009000200022</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03</originalsourceid><addsrcrecordid>eNp1kVtLwzAYhosoOKe_wfyBzqRNm_ZShofBQES9Dl9z2DK6ZiSp2mv_uOkmQxAvQvId3oc3vElyTfCMFDW-eSEFKVNC8zrDuMYYZ-PJTpLJcXD6632eXHi_iRssL_NJ8vXcQ2vCgKCTyHRBdX6srEZhrVAw3vcKOeV3tvOxtih8WOSHLk6DEWjloOtbcGg9SGc_B9hBMEEhs921EGkjEwln4i60SCqtRPAj3UFAsfUOzsBlcqah9erq554mb_d3r_PHdPn0sJjfLlNBCQlpXRe0qJRqyrIsdFY1VDaikTWRhcJC0IxmDGPGZCY0bnLKSq1lHtdZFT8OOJ8miwNXWtjwnTNbcAO3YPi-Yd2Kg4tOW8XzCkipG0KhACpw3RRlRQgjNaasYVhG1uzA8sKo1vKN7V0XzfN9HPxPHFHADgLhrPdO6aMBgvkY5L_Kb1jWkIo</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria</title><source>IngentaConnect Journals</source><source>SciELO</source><creator>Costa, Neusa Motta de Freitas ; Melo, Bruno Raposo ; Brito, Rosana Tavares ; Fernandes, Gustavo Vicentis de Oliveira ; Bernardo, Vagner Gonçalves ; Fonseca, Eliene Carvalho ; Conz, Marcio Baltazar ; Soares, Glória Almeida ; Granjeiro, José Mauro</creator><creatorcontrib>Costa, Neusa Motta de Freitas ; Melo, Bruno Raposo ; Brito, Rosana Tavares ; Fernandes, Gustavo Vicentis de Oliveira ; Bernardo, Vagner Gonçalves ; Fonseca, Eliene Carvalho ; Conz, Marcio Baltazar ; Soares, Glória Almeida ; Granjeiro, José Mauro</creatorcontrib><description>The objective of the present study was to evaluate the quality and intensity of the tissue response to two synthetic hydroxyapatites implanted in critical defects in the skulls of rats. Sixty animals were divided into three experimental groups: I (control), II (HA-1 = HA with 28% crystallinity) and III (HA-2 = HA with 70% crystallinity). They were sacrificed 1, 3, 6, and 9 months after implantation (n = 5 individuals per group/period). Histomorphometric analysis included i) counting of polymorphonuclear leucocytes, mast cells, macrophages and foreign body multinucleated giant cells stained with anti-lysozyme; ii) microvascular density stained with anti-Factor VIII and iii) degree of cell proliferation stained with anti-PCNA. There were no significant differences between the experimental groups in either the quality or quantity of cells in the inflammatory infiltrate, or the degree of angiogenesis and cell proliferation. We conclude that HA-1 and HA-2 are biocompatible and that the physico-chemical differences of these biomaterials did not affect cellular response.</description><identifier>ISSN: 1516-1439</identifier><identifier>ISSN: 1980-5373</identifier><identifier>EISSN: 1516-1439</identifier><identifier>DOI: 10.1590/S1516-14392009000200022</identifier><language>eng</language><publisher>ABM, ABC, ABPol</publisher><subject>bone repair ; ENGINEERING, CHEMICAL ; histomorphometry ; hydroxyapatite ; immunohistochemistry ; MATERIALS SCIENCE, MULTIDISCIPLINARY ; METALLURGY &amp; METALLURGICAL ENGINEERING</subject><ispartof>Materials research (São Carlos, São Paulo, Brazil), 2009-06, Vol.12 (2), p.245-251</ispartof><rights>This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03</citedby><cites>FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,24150,27924,27925</link.rule.ids></links><search><creatorcontrib>Costa, Neusa Motta de Freitas</creatorcontrib><creatorcontrib>Melo, Bruno Raposo</creatorcontrib><creatorcontrib>Brito, Rosana Tavares</creatorcontrib><creatorcontrib>Fernandes, Gustavo Vicentis de Oliveira</creatorcontrib><creatorcontrib>Bernardo, Vagner Gonçalves</creatorcontrib><creatorcontrib>Fonseca, Eliene Carvalho</creatorcontrib><creatorcontrib>Conz, Marcio Baltazar</creatorcontrib><creatorcontrib>Soares, Glória Almeida</creatorcontrib><creatorcontrib>Granjeiro, José Mauro</creatorcontrib><title>Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria</title><title>Materials research (São Carlos, São Paulo, Brazil)</title><addtitle>Mat. Res</addtitle><description>The objective of the present study was to evaluate the quality and intensity of the tissue response to two synthetic hydroxyapatites implanted in critical defects in the skulls of rats. Sixty animals were divided into three experimental groups: I (control), II (HA-1 = HA with 28% crystallinity) and III (HA-2 = HA with 70% crystallinity). They were sacrificed 1, 3, 6, and 9 months after implantation (n = 5 individuals per group/period). Histomorphometric analysis included i) counting of polymorphonuclear leucocytes, mast cells, macrophages and foreign body multinucleated giant cells stained with anti-lysozyme; ii) microvascular density stained with anti-Factor VIII and iii) degree of cell proliferation stained with anti-PCNA. There were no significant differences between the experimental groups in either the quality or quantity of cells in the inflammatory infiltrate, or the degree of angiogenesis and cell proliferation. We conclude that HA-1 and HA-2 are biocompatible and that the physico-chemical differences of these biomaterials did not affect cellular response.</description><subject>bone repair</subject><subject>ENGINEERING, CHEMICAL</subject><subject>histomorphometry</subject><subject>hydroxyapatite</subject><subject>immunohistochemistry</subject><subject>MATERIALS SCIENCE, MULTIDISCIPLINARY</subject><subject>METALLURGY &amp; METALLURGICAL ENGINEERING</subject><issn>1516-1439</issn><issn>1980-5373</issn><issn>1516-1439</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp1kVtLwzAYhosoOKe_wfyBzqRNm_ZShofBQES9Dl9z2DK6ZiSp2mv_uOkmQxAvQvId3oc3vElyTfCMFDW-eSEFKVNC8zrDuMYYZ-PJTpLJcXD6632eXHi_iRssL_NJ8vXcQ2vCgKCTyHRBdX6srEZhrVAw3vcKOeV3tvOxtih8WOSHLk6DEWjloOtbcGg9SGc_B9hBMEEhs921EGkjEwln4i60SCqtRPAj3UFAsfUOzsBlcqah9erq554mb_d3r_PHdPn0sJjfLlNBCQlpXRe0qJRqyrIsdFY1VDaikTWRhcJC0IxmDGPGZCY0bnLKSq1lHtdZFT8OOJ8miwNXWtjwnTNbcAO3YPi-Yd2Kg4tOW8XzCkipG0KhACpw3RRlRQgjNaasYVhG1uzA8sKo1vKN7V0XzfN9HPxPHFHADgLhrPdO6aMBgvkY5L_Kb1jWkIo</recordid><startdate>20090601</startdate><enddate>20090601</enddate><creator>Costa, Neusa Motta de Freitas</creator><creator>Melo, Bruno Raposo</creator><creator>Brito, Rosana Tavares</creator><creator>Fernandes, Gustavo Vicentis de Oliveira</creator><creator>Bernardo, Vagner Gonçalves</creator><creator>Fonseca, Eliene Carvalho</creator><creator>Conz, Marcio Baltazar</creator><creator>Soares, Glória Almeida</creator><creator>Granjeiro, José Mauro</creator><general>ABM, ABC, ABPol</general><general>Associação Brasileira de Metalurgia e Materiais (ABM); Associação Brasileira de Cerâmica (ABC); Associação Brasileira de Polímeros (ABPol)</general><scope>AAYXX</scope><scope>CITATION</scope><scope>GPN</scope><scope>DOA</scope></search><sort><creationdate>20090601</creationdate><title>Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria</title><author>Costa, Neusa Motta de Freitas ; Melo, Bruno Raposo ; Brito, Rosana Tavares ; Fernandes, Gustavo Vicentis de Oliveira ; Bernardo, Vagner Gonçalves ; Fonseca, Eliene Carvalho ; Conz, Marcio Baltazar ; Soares, Glória Almeida ; Granjeiro, José Mauro</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>bone repair</topic><topic>ENGINEERING, CHEMICAL</topic><topic>histomorphometry</topic><topic>hydroxyapatite</topic><topic>immunohistochemistry</topic><topic>MATERIALS SCIENCE, MULTIDISCIPLINARY</topic><topic>METALLURGY &amp; METALLURGICAL ENGINEERING</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Costa, Neusa Motta de Freitas</creatorcontrib><creatorcontrib>Melo, Bruno Raposo</creatorcontrib><creatorcontrib>Brito, Rosana Tavares</creatorcontrib><creatorcontrib>Fernandes, Gustavo Vicentis de Oliveira</creatorcontrib><creatorcontrib>Bernardo, Vagner Gonçalves</creatorcontrib><creatorcontrib>Fonseca, Eliene Carvalho</creatorcontrib><creatorcontrib>Conz, Marcio Baltazar</creatorcontrib><creatorcontrib>Soares, Glória Almeida</creatorcontrib><creatorcontrib>Granjeiro, José Mauro</creatorcontrib><collection>CrossRef</collection><collection>SciELO</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Materials research (São Carlos, São Paulo, Brazil)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Costa, Neusa Motta de Freitas</au><au>Melo, Bruno Raposo</au><au>Brito, Rosana Tavares</au><au>Fernandes, Gustavo Vicentis de Oliveira</au><au>Bernardo, Vagner Gonçalves</au><au>Fonseca, Eliene Carvalho</au><au>Conz, Marcio Baltazar</au><au>Soares, Glória Almeida</au><au>Granjeiro, José Mauro</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria</atitle><jtitle>Materials research (São Carlos, São Paulo, Brazil)</jtitle><addtitle>Mat. Res</addtitle><date>2009-06-01</date><risdate>2009</risdate><volume>12</volume><issue>2</issue><spage>245</spage><epage>251</epage><pages>245-251</pages><issn>1516-1439</issn><issn>1980-5373</issn><eissn>1516-1439</eissn><abstract>The objective of the present study was to evaluate the quality and intensity of the tissue response to two synthetic hydroxyapatites implanted in critical defects in the skulls of rats. Sixty animals were divided into three experimental groups: I (control), II (HA-1 = HA with 28% crystallinity) and III (HA-2 = HA with 70% crystallinity). They were sacrificed 1, 3, 6, and 9 months after implantation (n = 5 individuals per group/period). Histomorphometric analysis included i) counting of polymorphonuclear leucocytes, mast cells, macrophages and foreign body multinucleated giant cells stained with anti-lysozyme; ii) microvascular density stained with anti-Factor VIII and iii) degree of cell proliferation stained with anti-PCNA. There were no significant differences between the experimental groups in either the quality or quantity of cells in the inflammatory infiltrate, or the degree of angiogenesis and cell proliferation. We conclude that HA-1 and HA-2 are biocompatible and that the physico-chemical differences of these biomaterials did not affect cellular response.</abstract><pub>ABM, ABC, ABPol</pub><doi>10.1590/S1516-14392009000200022</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1516-1439
ispartof Materials research (São Carlos, São Paulo, Brazil), 2009-06, Vol.12 (2), p.245-251
issn 1516-1439
1980-5373
1516-1439
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_38a16fb14a5a4c09b56811719047b70d
source IngentaConnect Journals; SciELO
subjects bone repair
ENGINEERING, CHEMICAL
histomorphometry
hydroxyapatite
immunohistochemistry
MATERIALS SCIENCE, MULTIDISCIPLINARY
METALLURGY & METALLURGICAL ENGINEERING
title Quality and intensity of the tissue response to two synthetic granular hydroxyapatite implanted in critical defects of rat calvaria
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T11%3A39%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scielo_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Quality%20and%20intensity%20of%20the%20tissue%20response%20to%20two%20synthetic%20granular%20hydroxyapatite%20implanted%20in%20critical%20defects%20of%20rat%20calvaria&rft.jtitle=Materials%20research%20(S%C3%A3o%20Carlos,%20S%C3%A3o%20Paulo,%20Brazil)&rft.au=Costa,%20Neusa%20Motta%20de%20Freitas&rft.date=2009-06-01&rft.volume=12&rft.issue=2&rft.spage=245&rft.epage=251&rft.pages=245-251&rft.issn=1516-1439&rft.eissn=1516-1439&rft_id=info:doi/10.1590/S1516-14392009000200022&rft_dat=%3Cscielo_doaj_%3ES1516_14392009000200022%3C/scielo_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c411t-995458eeb6665f28b4dbcbd91d5e0cc424270077d2cf0b3476ffd3eb678143a03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_scielo_id=S1516_14392009000200022&rfr_iscdi=true