Loading…
DIAGNOSTIC ACCURACY OF ONE SAMPLE OR TWO SAMPLES QUANTITATIVE FECAL IMMUNOCHEMICAL TESTS FOR INTESTINAL NEOPLASIA DETECTION
Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µ...
Saved in:
Published in: | Arquivos de gastroenterologia 2020-09, Vol.57 (3), p.316-322 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening.
Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test.
Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings.
Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant.
The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence. |
---|---|
ISSN: | 0004-2803 1678-4219 1678-4219 |
DOI: | 10.1590/s0004-2803.202000000-58 |