Loading…

Custom-made iliac fenestrated endoprosthesis for the treatment of internal iliac artery aneurysm with preservation of the superior gluteal artery

A 56-year-old man with huge bilateral internal iliac artery aneurysms (IIAAs) had emergently undergone right common iliac artery replacement. Intermittent claudication was induced by 8 minutes of walking on postoperative day 16. Endovascular repair using a custom-made iliac fenestrated endoprosthesi...

Full description

Saved in:
Bibliographic Details
Published in:Journal of vascular surgery cases and innovative techniques 2021-09, Vol.7 (3), p.532-535
Main Authors: Nishi, Satoshi, Arima, Daisuke, Matsumoto, Ryumon, Kurahashi, Kanan, Yoshimoto, Akihiro, Suematsu, Yoshihiro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A 56-year-old man with huge bilateral internal iliac artery aneurysms (IIAAs) had emergently undergone right common iliac artery replacement. Intermittent claudication was induced by 8 minutes of walking on postoperative day 16. Endovascular repair using a custom-made iliac fenestrated endoprosthesis for the treatment of the left IIAA with preservation of the superior gluteal artery was performed on postoperative day 20 without discharging the patient. The patient had no ischemic complications. When an IIAA with a short length (21 mm) of the common iliac artery is anatomically suitable, the placement of a custom-made iliac fenestrated endoprosthesis is a feasible and effective technique.
ISSN:2468-4287
2468-4287
DOI:10.1016/j.jvscit.2021.07.002