Loading…

A resonant high-pressure microsensor based on a composite pressure-sensitive mechanism of diaphragm bending and volume compression

In this paper, a composite pressure-sensitive mechanism combining diaphragm bending and volume compression was developed for resonant pressure microsensors to achieve high-pressure measurements with excellent accuracy. The composite mechanism was explained, and the sensor structure was designed base...

Full description

Saved in:
Bibliographic Details
Published in:Microsystems & nanoengineering 2024-03, Vol.10 (1), p.38-38, Article 38
Main Authors: Qian, Pan, Yu, Zongze, Yu, Jie, Lu, Yulan, Xie, Bo, Chen, Jian, Chen, Deyong, Wang, Junbo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this paper, a composite pressure-sensitive mechanism combining diaphragm bending and volume compression was developed for resonant pressure microsensors to achieve high-pressure measurements with excellent accuracy. The composite mechanism was explained, and the sensor structure was designed based on theoretical analysis and finite element simulation. An all-silicon resonant high-pressure microsensor with multiple miniaturized cavities and dual resonators was developed, where dual resonators positioned in two resonant cavities with suitably different widths are used to perform opposite characteristics in pressure and the same characteristics at different temperatures, which can improve pressure sensitivities and realize temperature self-compensation by differential frequency output. The microsensor was fabricated by microfabrication, and the experimental results showed that the sensor had an accuracy of ±0.015% full scale (FS) in a pressure range of 0.1~100 MPa and a temperature range of −10~50 °C. The pressure sensitivity of the differential frequency was 261.10 Hz/MPa (~2523 ppm/MPa) at a temperature of 20 °C, and the temperature sensitivities of the dual resonators were −1.54 Hz/°C (~−14.5 ppm/°C) and −1.57 Hz/°C (~−15.6 ppm/°C) at a pressure of 2 MPa. The differential output had an outstanding stability within ±0.02 Hz under constant temperature and pressure. Thus, this research provides a convenient solution for high-pressure measurements because of its advantages, namely, large range, excellent accuracy and stability.
ISSN:2055-7434
2096-1030
2055-7434
DOI:10.1038/s41378-024-00667-8