Loading…

The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study

Purpose: This multicenter prospective study aimed to evaluate the accuracy of the cup alignment of an accelerometer-based portable navigation system (AP navigation) for a total hip arthroplasty (THA) in spine position. Methods: This study prospectively enrolled 324 THAs using supine position in 9 ho...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Joint Surgery and Research 2023-12, Vol.1 (1), p.133-138
Main Authors: Minoda, Yukihide, Ito, Masayuki, Iwakiri, Kentaro, Uchiyama, Katsufumi, Kawasaki, Masashi, Kanda, Akio, Jinno, Tetsuya, Sugama, Ryo, Chiba, Daisuke, Hasegawa, Masahiro, Fujishiro, Takaaki
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2121-3c5dcc3a3da3ee11c0422962a4cc86369dfd48a2c12e8db54d56d219d0f91e113
container_end_page 138
container_issue 1
container_start_page 133
container_title Journal of Joint Surgery and Research
container_volume 1
creator Minoda, Yukihide
Ito, Masayuki
Iwakiri, Kentaro
Uchiyama, Katsufumi
Kawasaki, Masashi
Kanda, Akio
Jinno, Tetsuya
Sugama, Ryo
Chiba, Daisuke
Hasegawa, Masahiro
Fujishiro, Takaaki
description Purpose: This multicenter prospective study aimed to evaluate the accuracy of the cup alignment of an accelerometer-based portable navigation system (AP navigation) for a total hip arthroplasty (THA) in spine position. Methods: This study prospectively enrolled 324 THAs using supine position in 9 hospitals. An AP navigation was used for cup fixation and the intraoperative navigation data (cup alignment, pelvic tilt, and pelvic rotation) were recorded. Computed tomography (CT) of the pelvis was performed 2 weeks post-operatively and cup alignment was measured on 3D-CT images. Result: The accuracy (absolute difference in cup alignment between the intraoperative navigation record and postoperative 3D-CT measurements) was 3 ​± ​3° (mean ​± ​standard deviation) for cup inclination and 3 ​± ​3° for cup anteversion. The pelvis tilted anteriorly in 148 hips (46%) and posteriorly in 162 hips (50%), and did not tilt in 14 hips (4%). The pelvis rotated toward the operating side in 179 hips (55%), toward the contralateral side in 112 hips (35%), and did not rotate in 33 hips (10%). Multiple regression analysis showed that the patients’ characteristics (sex, body mass index, diagnosis, Crowe classification, laterality, intraoperative pelvic tilt, intraoperative pelvic rotation, and cup size) and the surgical factors (approach, preparation time, number of screws, and institution) did not affect the accuracy of the navigation system. Conclusions: This is the first prospective multicenter study of this navigation system. The accuracy was not affected by patient characteristics, surgical factors, or substantial pelvic movement during cup fixation.
doi_str_mv 10.1016/j.jjoisr.2023.06.001
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_3c21f831268d4d04af5e6343056eb7ed</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_3c21f831268d4d04af5e6343056eb7ed</doaj_id><sourcerecordid>oai_doaj_org_article_3c21f831268d4d04af5e6343056eb7ed</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2121-3c5dcc3a3da3ee11c0422962a4cc86369dfd48a2c12e8db54d56d219d0f91e113</originalsourceid><addsrcrecordid>eNpNkcuK3DAQRU1IIMNk_iCL-gE7elljZxc6r4GBbDprUS2Vu2Vsy0jygP8pHxl1OoSs6sHlXC63qt5z1nDG9YexGcfgU2wEE7JhumGMv6ruRK_6-pG1_PV_-9vqIaWRMSb6nmve3lW_jhcCtHaLaHcIA-ByPWmiGGbKFOsTJnKwhpjxNBEs-OLPmH1YIO0p0wxDiJBDxgkufgWM-RLDOmHKO2zJL2eQn-FwhJkwbZFmWjL4BXLxTdvqFyrs5K_Aj4CwxpBWstm_EMzblL0teoqQ8ub2d9WbAadED3_nffXz65fj4Xv9_OPb0-HTc20FF7yWtnXWSpQOJRHnlikhei1QWdtpqXs3ONWhsFxQ506tcq12gveODT0venlfPd24LuBo1uhnjLsJ6M2fR4hnU2J6O5GRxXLoJBe6c8oxhUNLWirJWk2nR3KFpW4sW5KlSMM_HmfmWqAZza1Acy3QMG1KgfI3xyKVIg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study</title><source>ScienceDirect Journals</source><creator>Minoda, Yukihide ; Ito, Masayuki ; Iwakiri, Kentaro ; Uchiyama, Katsufumi ; Kawasaki, Masashi ; Kanda, Akio ; Jinno, Tetsuya ; Sugama, Ryo ; Chiba, Daisuke ; Hasegawa, Masahiro ; Fujishiro, Takaaki</creator><creatorcontrib>Minoda, Yukihide ; Ito, Masayuki ; Iwakiri, Kentaro ; Uchiyama, Katsufumi ; Kawasaki, Masashi ; Kanda, Akio ; Jinno, Tetsuya ; Sugama, Ryo ; Chiba, Daisuke ; Hasegawa, Masahiro ; Fujishiro, Takaaki</creatorcontrib><description>Purpose: This multicenter prospective study aimed to evaluate the accuracy of the cup alignment of an accelerometer-based portable navigation system (AP navigation) for a total hip arthroplasty (THA) in spine position. Methods: This study prospectively enrolled 324 THAs using supine position in 9 hospitals. An AP navigation was used for cup fixation and the intraoperative navigation data (cup alignment, pelvic tilt, and pelvic rotation) were recorded. Computed tomography (CT) of the pelvis was performed 2 weeks post-operatively and cup alignment was measured on 3D-CT images. Result: The accuracy (absolute difference in cup alignment between the intraoperative navigation record and postoperative 3D-CT measurements) was 3 ​± ​3° (mean ​± ​standard deviation) for cup inclination and 3 ​± ​3° for cup anteversion. The pelvis tilted anteriorly in 148 hips (46%) and posteriorly in 162 hips (50%), and did not tilt in 14 hips (4%). The pelvis rotated toward the operating side in 179 hips (55%), toward the contralateral side in 112 hips (35%), and did not rotate in 33 hips (10%). Multiple regression analysis showed that the patients’ characteristics (sex, body mass index, diagnosis, Crowe classification, laterality, intraoperative pelvic tilt, intraoperative pelvic rotation, and cup size) and the surgical factors (approach, preparation time, number of screws, and institution) did not affect the accuracy of the navigation system. Conclusions: This is the first prospective multicenter study of this navigation system. The accuracy was not affected by patient characteristics, surgical factors, or substantial pelvic movement during cup fixation.</description><identifier>ISSN: 2949-7051</identifier><identifier>EISSN: 2949-7051</identifier><identifier>DOI: 10.1016/j.jjoisr.2023.06.001</identifier><language>eng</language><publisher>Elsevier</publisher><subject>Accelerometer-based portable navigation system ; Accuracy ; Supine position ; Total hip arthroplasty</subject><ispartof>Journal of Joint Surgery and Research, 2023-12, Vol.1 (1), p.133-138</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2121-3c5dcc3a3da3ee11c0422962a4cc86369dfd48a2c12e8db54d56d219d0f91e113</cites><orcidid>0000-0002-0541-1736 ; 0000-0001-8629-2283 ; 0009-0006-7329-7310 ; 0000-0002-5434-9959</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Minoda, Yukihide</creatorcontrib><creatorcontrib>Ito, Masayuki</creatorcontrib><creatorcontrib>Iwakiri, Kentaro</creatorcontrib><creatorcontrib>Uchiyama, Katsufumi</creatorcontrib><creatorcontrib>Kawasaki, Masashi</creatorcontrib><creatorcontrib>Kanda, Akio</creatorcontrib><creatorcontrib>Jinno, Tetsuya</creatorcontrib><creatorcontrib>Sugama, Ryo</creatorcontrib><creatorcontrib>Chiba, Daisuke</creatorcontrib><creatorcontrib>Hasegawa, Masahiro</creatorcontrib><creatorcontrib>Fujishiro, Takaaki</creatorcontrib><title>The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study</title><title>Journal of Joint Surgery and Research</title><description>Purpose: This multicenter prospective study aimed to evaluate the accuracy of the cup alignment of an accelerometer-based portable navigation system (AP navigation) for a total hip arthroplasty (THA) in spine position. Methods: This study prospectively enrolled 324 THAs using supine position in 9 hospitals. An AP navigation was used for cup fixation and the intraoperative navigation data (cup alignment, pelvic tilt, and pelvic rotation) were recorded. Computed tomography (CT) of the pelvis was performed 2 weeks post-operatively and cup alignment was measured on 3D-CT images. Result: The accuracy (absolute difference in cup alignment between the intraoperative navigation record and postoperative 3D-CT measurements) was 3 ​± ​3° (mean ​± ​standard deviation) for cup inclination and 3 ​± ​3° for cup anteversion. The pelvis tilted anteriorly in 148 hips (46%) and posteriorly in 162 hips (50%), and did not tilt in 14 hips (4%). The pelvis rotated toward the operating side in 179 hips (55%), toward the contralateral side in 112 hips (35%), and did not rotate in 33 hips (10%). Multiple regression analysis showed that the patients’ characteristics (sex, body mass index, diagnosis, Crowe classification, laterality, intraoperative pelvic tilt, intraoperative pelvic rotation, and cup size) and the surgical factors (approach, preparation time, number of screws, and institution) did not affect the accuracy of the navigation system. Conclusions: This is the first prospective multicenter study of this navigation system. The accuracy was not affected by patient characteristics, surgical factors, or substantial pelvic movement during cup fixation.</description><subject>Accelerometer-based portable navigation system</subject><subject>Accuracy</subject><subject>Supine position</subject><subject>Total hip arthroplasty</subject><issn>2949-7051</issn><issn>2949-7051</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkcuK3DAQRU1IIMNk_iCL-gE7elljZxc6r4GBbDprUS2Vu2Vsy0jygP8pHxl1OoSs6sHlXC63qt5z1nDG9YexGcfgU2wEE7JhumGMv6ruRK_6-pG1_PV_-9vqIaWRMSb6nmve3lW_jhcCtHaLaHcIA-ByPWmiGGbKFOsTJnKwhpjxNBEs-OLPmH1YIO0p0wxDiJBDxgkufgWM-RLDOmHKO2zJL2eQn-FwhJkwbZFmWjL4BXLxTdvqFyrs5K_Aj4CwxpBWstm_EMzblL0teoqQ8ub2d9WbAadED3_nffXz65fj4Xv9_OPb0-HTc20FF7yWtnXWSpQOJRHnlikhei1QWdtpqXs3ONWhsFxQ506tcq12gveODT0venlfPd24LuBo1uhnjLsJ6M2fR4hnU2J6O5GRxXLoJBe6c8oxhUNLWirJWk2nR3KFpW4sW5KlSMM_HmfmWqAZza1Acy3QMG1KgfI3xyKVIg</recordid><startdate>202312</startdate><enddate>202312</enddate><creator>Minoda, Yukihide</creator><creator>Ito, Masayuki</creator><creator>Iwakiri, Kentaro</creator><creator>Uchiyama, Katsufumi</creator><creator>Kawasaki, Masashi</creator><creator>Kanda, Akio</creator><creator>Jinno, Tetsuya</creator><creator>Sugama, Ryo</creator><creator>Chiba, Daisuke</creator><creator>Hasegawa, Masahiro</creator><creator>Fujishiro, Takaaki</creator><general>Elsevier</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-0541-1736</orcidid><orcidid>https://orcid.org/0000-0001-8629-2283</orcidid><orcidid>https://orcid.org/0009-0006-7329-7310</orcidid><orcidid>https://orcid.org/0000-0002-5434-9959</orcidid></search><sort><creationdate>202312</creationdate><title>The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study</title><author>Minoda, Yukihide ; Ito, Masayuki ; Iwakiri, Kentaro ; Uchiyama, Katsufumi ; Kawasaki, Masashi ; Kanda, Akio ; Jinno, Tetsuya ; Sugama, Ryo ; Chiba, Daisuke ; Hasegawa, Masahiro ; Fujishiro, Takaaki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2121-3c5dcc3a3da3ee11c0422962a4cc86369dfd48a2c12e8db54d56d219d0f91e113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Accelerometer-based portable navigation system</topic><topic>Accuracy</topic><topic>Supine position</topic><topic>Total hip arthroplasty</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Minoda, Yukihide</creatorcontrib><creatorcontrib>Ito, Masayuki</creatorcontrib><creatorcontrib>Iwakiri, Kentaro</creatorcontrib><creatorcontrib>Uchiyama, Katsufumi</creatorcontrib><creatorcontrib>Kawasaki, Masashi</creatorcontrib><creatorcontrib>Kanda, Akio</creatorcontrib><creatorcontrib>Jinno, Tetsuya</creatorcontrib><creatorcontrib>Sugama, Ryo</creatorcontrib><creatorcontrib>Chiba, Daisuke</creatorcontrib><creatorcontrib>Hasegawa, Masahiro</creatorcontrib><creatorcontrib>Fujishiro, Takaaki</creatorcontrib><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of Joint Surgery and Research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Minoda, Yukihide</au><au>Ito, Masayuki</au><au>Iwakiri, Kentaro</au><au>Uchiyama, Katsufumi</au><au>Kawasaki, Masashi</au><au>Kanda, Akio</au><au>Jinno, Tetsuya</au><au>Sugama, Ryo</au><au>Chiba, Daisuke</au><au>Hasegawa, Masahiro</au><au>Fujishiro, Takaaki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study</atitle><jtitle>Journal of Joint Surgery and Research</jtitle><date>2023-12</date><risdate>2023</risdate><volume>1</volume><issue>1</issue><spage>133</spage><epage>138</epage><pages>133-138</pages><issn>2949-7051</issn><eissn>2949-7051</eissn><abstract>Purpose: This multicenter prospective study aimed to evaluate the accuracy of the cup alignment of an accelerometer-based portable navigation system (AP navigation) for a total hip arthroplasty (THA) in spine position. Methods: This study prospectively enrolled 324 THAs using supine position in 9 hospitals. An AP navigation was used for cup fixation and the intraoperative navigation data (cup alignment, pelvic tilt, and pelvic rotation) were recorded. Computed tomography (CT) of the pelvis was performed 2 weeks post-operatively and cup alignment was measured on 3D-CT images. Result: The accuracy (absolute difference in cup alignment between the intraoperative navigation record and postoperative 3D-CT measurements) was 3 ​± ​3° (mean ​± ​standard deviation) for cup inclination and 3 ​± ​3° for cup anteversion. The pelvis tilted anteriorly in 148 hips (46%) and posteriorly in 162 hips (50%), and did not tilt in 14 hips (4%). The pelvis rotated toward the operating side in 179 hips (55%), toward the contralateral side in 112 hips (35%), and did not rotate in 33 hips (10%). Multiple regression analysis showed that the patients’ characteristics (sex, body mass index, diagnosis, Crowe classification, laterality, intraoperative pelvic tilt, intraoperative pelvic rotation, and cup size) and the surgical factors (approach, preparation time, number of screws, and institution) did not affect the accuracy of the navigation system. Conclusions: This is the first prospective multicenter study of this navigation system. The accuracy was not affected by patient characteristics, surgical factors, or substantial pelvic movement during cup fixation.</abstract><pub>Elsevier</pub><doi>10.1016/j.jjoisr.2023.06.001</doi><tpages>6</tpages><orcidid>https://orcid.org/0000-0002-0541-1736</orcidid><orcidid>https://orcid.org/0000-0001-8629-2283</orcidid><orcidid>https://orcid.org/0009-0006-7329-7310</orcidid><orcidid>https://orcid.org/0000-0002-5434-9959</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2949-7051
ispartof Journal of Joint Surgery and Research, 2023-12, Vol.1 (1), p.133-138
issn 2949-7051
2949-7051
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_3c21f831268d4d04af5e6343056eb7ed
source ScienceDirect Journals
subjects Accelerometer-based portable navigation system
Accuracy
Supine position
Total hip arthroplasty
title The accuracy of an accelerometer-based portable navigation system for total hip arthroplasty using 3D CT measurement in the supine position: a prospective multicenter study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T19%3A32%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20accuracy%20of%20an%20accelerometer-based%20portable%20navigation%20system%20for%20total%20hip%20arthroplasty%20using%203D%20CT%20measurement%20in%20the%20supine%20position:%20a%20prospective%20multicenter%20study&rft.jtitle=Journal%20of%20Joint%20Surgery%20and%20Research&rft.au=Minoda,%20Yukihide&rft.date=2023-12&rft.volume=1&rft.issue=1&rft.spage=133&rft.epage=138&rft.pages=133-138&rft.issn=2949-7051&rft.eissn=2949-7051&rft_id=info:doi/10.1016/j.jjoisr.2023.06.001&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_3c21f831268d4d04af5e6343056eb7ed%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2121-3c5dcc3a3da3ee11c0422962a4cc86369dfd48a2c12e8db54d56d219d0f91e113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true