Loading…

Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization

Background: While most catheters are designed for the natural anatomy of the coronaries at the origin, we often end up using multiple catheters in failed attempts to hook the coronary ostia in case of unusual origins. We had similar issues where we used multiple catheters in vain during femoral appr...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Indian College of Cardiology 2024-01, Vol.14 (1), p.21-24
Main Authors: Nimmagadda, Satya, Shafi, P, Devalkar, Ashish, Malladi, Srinivasa, Vajhala, Adilakshmi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2813-49e55db45e345ae413eaeecde41520ec6219d45e58705f75869d792f09b748d3
container_end_page 24
container_issue 1
container_start_page 21
container_title Journal of Indian College of Cardiology
container_volume 14
creator Nimmagadda, Satya
Shafi, P
Devalkar, Ashish
Malladi, Srinivasa
Vajhala, Adilakshmi
description Background: While most catheters are designed for the natural anatomy of the coronaries at the origin, we often end up using multiple catheters in failed attempts to hook the coronary ostia in case of unusual origins. We had similar issues where we used multiple catheters in vain during femoral approach catheterizations and ended up successfully hooking with a tiger (TIG) catheter in a few of our cases in the catheterization laboratory. We mostly used Judkins left (JL) and Judkins right (JR) catheters as the first choice for femoral approach catheterizations. Hence, we wanted to see how frequently we had to use catheters other than JL and JR and which catheter was most useful in such cases. Methods: This is a retrospective study of catheterization laboratory angiographic data and recordings involving femoral artery approach coronary catheterization at King George Hospital, Visakhapatnam, from January 2022 to December 2022. We analyzed and interpreted the data of difficult femoral artery catheterizations where JL/JR catheters could not hook the coronaries successfully. We tabulated such data in percentages to understand which catheter was most useful in such cases. We analyzed the angiograms of such cases to understand the coronary origins. Results: Overall, 1130 cases underwent femoral artery approach coronary angiograms. Of them, 1100 (97.3%) cases could be hooked with JL and JR catheters. Thirty (2.65%) cases were found to be difficult femoral artery approach catheterizations where either JL or JR catheter could not be used successfully. Out of those difficult ones (30 cases - 100%), 22 (73.3%) cases could be hooked with TIG catheter, 4 (13.33%) cases with extra backup (EBU) catheter, 1 (3.33%) case with JR side hole (JRSH) catheter, 2 (6.66%) cases with no torque right (NTR) catheter, and 1 (3.33%) case with multipurpose catheter (MPA). Out of these 30 cases, a left coronary angiogram was needed other than a JL catheter in 8 cases, while a right coronary angiogram was needed other than a JR catheter in 25 cases, showing that the right coronary artery (RCA) was mostly involved in difficult catheterizations. For left coronary angiograms, 4 cases hooked with TIG (1 case - posteriorly/low takeoff, 1 - high takeoff, 1 - mid-takeoff, and 1 - RCA/left main coronary artery [LMCA] from left sinus) and 4 cases with EBU catheter (1 - anterior/high takeoff, 2 - high takeoffs, and 1 - posteriorly/high takeoff). For right coronary angiograms, 21 cases hooked with TIG
doi_str_mv 10.4103/jicc.jicc_33_23
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_3d75557d0e79406396b8b8de1d695ab0</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A815567514</galeid><doaj_id>oai_doaj_org_article_3d75557d0e79406396b8b8de1d695ab0</doaj_id><sourcerecordid>A815567514</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2813-49e55db45e345ae413eaeecde41520ec6219d45e58705f75869d792f09b748d3</originalsourceid><addsrcrecordid>eNqNUk2LWyEUlTKFhkzW3T7oOok-vX4sQzofgRm6yV58ek0MSQy-10X768cknX7AMFRBL-eec7zCIeQzozPBKJ_vkvez82E5ty3_QEZty_iUSwY3ZMRAsqnWjH0ik77fUUpbburiI_K8ThsszdINWxxqEXNpvqYYk_--H5p7POTi9s2i1N6PZnE6lez8tlnmko-uIq-69NMNKR9vycfo9j1Oft1jsr6_Wy8fp0_fHlbLxdPUt7qOJQwChE4AcgEOBePoEH2oFbQUvWyZCbULWlGICrQ0QZk2UtMpoQMfk9XVNmS3s6eSDnUWm12yFyCXjXVlSH6PlgcFACpQVEZQyY3sdKcDsiANuI5Wry9Xr42r9HSMeSjOH1Lv7UIzAKmAiXdZylAmhWGysmZvsOoOeEg-HzGmiv9j-1-Cv1-YXwW-5L4vGH__nlF7ToK9hOBPEvgL3Eyk_Q</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization</title><source>Medknow Open Access Journals</source><creator>Nimmagadda, Satya ; Shafi, P ; Devalkar, Ashish ; Malladi, Srinivasa ; Vajhala, Adilakshmi</creator><creatorcontrib>Nimmagadda, Satya ; Shafi, P ; Devalkar, Ashish ; Malladi, Srinivasa ; Vajhala, Adilakshmi</creatorcontrib><description>Background: While most catheters are designed for the natural anatomy of the coronaries at the origin, we often end up using multiple catheters in failed attempts to hook the coronary ostia in case of unusual origins. We had similar issues where we used multiple catheters in vain during femoral approach catheterizations and ended up successfully hooking with a tiger (TIG) catheter in a few of our cases in the catheterization laboratory. We mostly used Judkins left (JL) and Judkins right (JR) catheters as the first choice for femoral approach catheterizations. Hence, we wanted to see how frequently we had to use catheters other than JL and JR and which catheter was most useful in such cases. Methods: This is a retrospective study of catheterization laboratory angiographic data and recordings involving femoral artery approach coronary catheterization at King George Hospital, Visakhapatnam, from January 2022 to December 2022. We analyzed and interpreted the data of difficult femoral artery catheterizations where JL/JR catheters could not hook the coronaries successfully. We tabulated such data in percentages to understand which catheter was most useful in such cases. We analyzed the angiograms of such cases to understand the coronary origins. Results: Overall, 1130 cases underwent femoral artery approach coronary angiograms. Of them, 1100 (97.3%) cases could be hooked with JL and JR catheters. Thirty (2.65%) cases were found to be difficult femoral artery approach catheterizations where either JL or JR catheter could not be used successfully. Out of those difficult ones (30 cases - 100%), 22 (73.3%) cases could be hooked with TIG catheter, 4 (13.33%) cases with extra backup (EBU) catheter, 1 (3.33%) case with JR side hole (JRSH) catheter, 2 (6.66%) cases with no torque right (NTR) catheter, and 1 (3.33%) case with multipurpose catheter (MPA). Out of these 30 cases, a left coronary angiogram was needed other than a JL catheter in 8 cases, while a right coronary angiogram was needed other than a JR catheter in 25 cases, showing that the right coronary artery (RCA) was mostly involved in difficult catheterizations. For left coronary angiograms, 4 cases hooked with TIG (1 case - posteriorly/low takeoff, 1 - high takeoff, 1 - mid-takeoff, and 1 - RCA/left main coronary artery [LMCA] from left sinus) and 4 cases with EBU catheter (1 - anterior/high takeoff, 2 - high takeoffs, and 1 - posteriorly/high takeoff). For right coronary angiograms, 21 cases hooked with TIG (3 cases - left sinus/anteriorly, 3 - high takeoff/anteriorly, 3 - low takeoff, 2 - mid takeoff/anteriorly, 3 - posterior/high takeoff, 1 - RCA/LMCA from left sinus, 1 - posteriorly/left sinus, 3 - high takeoff, 1 - anteriorly/low takeoff, and 1 - right sinus/mid-takeoff), 1 case with JRSH, 1 case with MPA (anterior/high takeoff) and 2 cases with NTR (1 - low takeoff and 1 - high takeoff). Conclusion: We found that the TIG catheter was useful in difficult femoral approach catheterizations in the majority of cases and it can be tried in difficult cases. Keywords: Anomalous coronary artery, catheterization, coronary angiogram, tiger, tiger catheter</description><identifier>ISSN: 1561-8811</identifier><identifier>EISSN: 2213-3615</identifier><identifier>DOI: 10.4103/jicc.jicc_33_23</identifier><language>eng</language><publisher>Medknow Publications and Media Pvt. Ltd</publisher><subject>Analysis ; anomalous coronary artery ; Catheterization ; coronary angiogram ; tiger ; tiger catheter</subject><ispartof>Journal of Indian College of Cardiology, 2024-01, Vol.14 (1), p.21-24</ispartof><rights>COPYRIGHT 2024 Medknow Publications and Media Pvt. Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2813-49e55db45e345ae413eaeecde41520ec6219d45e58705f75869d792f09b748d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Nimmagadda, Satya</creatorcontrib><creatorcontrib>Shafi, P</creatorcontrib><creatorcontrib>Devalkar, Ashish</creatorcontrib><creatorcontrib>Malladi, Srinivasa</creatorcontrib><creatorcontrib>Vajhala, Adilakshmi</creatorcontrib><title>Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization</title><title>Journal of Indian College of Cardiology</title><description>Background: While most catheters are designed for the natural anatomy of the coronaries at the origin, we often end up using multiple catheters in failed attempts to hook the coronary ostia in case of unusual origins. We had similar issues where we used multiple catheters in vain during femoral approach catheterizations and ended up successfully hooking with a tiger (TIG) catheter in a few of our cases in the catheterization laboratory. We mostly used Judkins left (JL) and Judkins right (JR) catheters as the first choice for femoral approach catheterizations. Hence, we wanted to see how frequently we had to use catheters other than JL and JR and which catheter was most useful in such cases. Methods: This is a retrospective study of catheterization laboratory angiographic data and recordings involving femoral artery approach coronary catheterization at King George Hospital, Visakhapatnam, from January 2022 to December 2022. We analyzed and interpreted the data of difficult femoral artery catheterizations where JL/JR catheters could not hook the coronaries successfully. We tabulated such data in percentages to understand which catheter was most useful in such cases. We analyzed the angiograms of such cases to understand the coronary origins. Results: Overall, 1130 cases underwent femoral artery approach coronary angiograms. Of them, 1100 (97.3%) cases could be hooked with JL and JR catheters. Thirty (2.65%) cases were found to be difficult femoral artery approach catheterizations where either JL or JR catheter could not be used successfully. Out of those difficult ones (30 cases - 100%), 22 (73.3%) cases could be hooked with TIG catheter, 4 (13.33%) cases with extra backup (EBU) catheter, 1 (3.33%) case with JR side hole (JRSH) catheter, 2 (6.66%) cases with no torque right (NTR) catheter, and 1 (3.33%) case with multipurpose catheter (MPA). Out of these 30 cases, a left coronary angiogram was needed other than a JL catheter in 8 cases, while a right coronary angiogram was needed other than a JR catheter in 25 cases, showing that the right coronary artery (RCA) was mostly involved in difficult catheterizations. For left coronary angiograms, 4 cases hooked with TIG (1 case - posteriorly/low takeoff, 1 - high takeoff, 1 - mid-takeoff, and 1 - RCA/left main coronary artery [LMCA] from left sinus) and 4 cases with EBU catheter (1 - anterior/high takeoff, 2 - high takeoffs, and 1 - posteriorly/high takeoff). For right coronary angiograms, 21 cases hooked with TIG (3 cases - left sinus/anteriorly, 3 - high takeoff/anteriorly, 3 - low takeoff, 2 - mid takeoff/anteriorly, 3 - posterior/high takeoff, 1 - RCA/LMCA from left sinus, 1 - posteriorly/left sinus, 3 - high takeoff, 1 - anteriorly/low takeoff, and 1 - right sinus/mid-takeoff), 1 case with JRSH, 1 case with MPA (anterior/high takeoff) and 2 cases with NTR (1 - low takeoff and 1 - high takeoff). Conclusion: We found that the TIG catheter was useful in difficult femoral approach catheterizations in the majority of cases and it can be tried in difficult cases. Keywords: Anomalous coronary artery, catheterization, coronary angiogram, tiger, tiger catheter</description><subject>Analysis</subject><subject>anomalous coronary artery</subject><subject>Catheterization</subject><subject>coronary angiogram</subject><subject>tiger</subject><subject>tiger catheter</subject><issn>1561-8811</issn><issn>2213-3615</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNqNUk2LWyEUlTKFhkzW3T7oOok-vX4sQzofgRm6yV58ek0MSQy-10X768cknX7AMFRBL-eec7zCIeQzozPBKJ_vkvez82E5ty3_QEZty_iUSwY3ZMRAsqnWjH0ik77fUUpbburiI_K8ThsszdINWxxqEXNpvqYYk_--H5p7POTi9s2i1N6PZnE6lez8tlnmko-uIq-69NMNKR9vycfo9j1Oft1jsr6_Wy8fp0_fHlbLxdPUt7qOJQwChE4AcgEOBePoEH2oFbQUvWyZCbULWlGICrQ0QZk2UtMpoQMfk9XVNmS3s6eSDnUWm12yFyCXjXVlSH6PlgcFACpQVEZQyY3sdKcDsiANuI5Wry9Xr42r9HSMeSjOH1Lv7UIzAKmAiXdZylAmhWGysmZvsOoOeEg-HzGmiv9j-1-Cv1-YXwW-5L4vGH__nlF7ToK9hOBPEvgL3Eyk_Q</recordid><startdate>20240101</startdate><enddate>20240101</enddate><creator>Nimmagadda, Satya</creator><creator>Shafi, P</creator><creator>Devalkar, Ashish</creator><creator>Malladi, Srinivasa</creator><creator>Vajhala, Adilakshmi</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>20240101</creationdate><title>Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization</title><author>Nimmagadda, Satya ; Shafi, P ; Devalkar, Ashish ; Malladi, Srinivasa ; Vajhala, Adilakshmi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2813-49e55db45e345ae413eaeecde41520ec6219d45e58705f75869d792f09b748d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Analysis</topic><topic>anomalous coronary artery</topic><topic>Catheterization</topic><topic>coronary angiogram</topic><topic>tiger</topic><topic>tiger catheter</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nimmagadda, Satya</creatorcontrib><creatorcontrib>Shafi, P</creatorcontrib><creatorcontrib>Devalkar, Ashish</creatorcontrib><creatorcontrib>Malladi, Srinivasa</creatorcontrib><creatorcontrib>Vajhala, Adilakshmi</creatorcontrib><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of Indian College of Cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nimmagadda, Satya</au><au>Shafi, P</au><au>Devalkar, Ashish</au><au>Malladi, Srinivasa</au><au>Vajhala, Adilakshmi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization</atitle><jtitle>Journal of Indian College of Cardiology</jtitle><date>2024-01-01</date><risdate>2024</risdate><volume>14</volume><issue>1</issue><spage>21</spage><epage>24</epage><pages>21-24</pages><issn>1561-8811</issn><eissn>2213-3615</eissn><abstract>Background: While most catheters are designed for the natural anatomy of the coronaries at the origin, we often end up using multiple catheters in failed attempts to hook the coronary ostia in case of unusual origins. We had similar issues where we used multiple catheters in vain during femoral approach catheterizations and ended up successfully hooking with a tiger (TIG) catheter in a few of our cases in the catheterization laboratory. We mostly used Judkins left (JL) and Judkins right (JR) catheters as the first choice for femoral approach catheterizations. Hence, we wanted to see how frequently we had to use catheters other than JL and JR and which catheter was most useful in such cases. Methods: This is a retrospective study of catheterization laboratory angiographic data and recordings involving femoral artery approach coronary catheterization at King George Hospital, Visakhapatnam, from January 2022 to December 2022. We analyzed and interpreted the data of difficult femoral artery catheterizations where JL/JR catheters could not hook the coronaries successfully. We tabulated such data in percentages to understand which catheter was most useful in such cases. We analyzed the angiograms of such cases to understand the coronary origins. Results: Overall, 1130 cases underwent femoral artery approach coronary angiograms. Of them, 1100 (97.3%) cases could be hooked with JL and JR catheters. Thirty (2.65%) cases were found to be difficult femoral artery approach catheterizations where either JL or JR catheter could not be used successfully. Out of those difficult ones (30 cases - 100%), 22 (73.3%) cases could be hooked with TIG catheter, 4 (13.33%) cases with extra backup (EBU) catheter, 1 (3.33%) case with JR side hole (JRSH) catheter, 2 (6.66%) cases with no torque right (NTR) catheter, and 1 (3.33%) case with multipurpose catheter (MPA). Out of these 30 cases, a left coronary angiogram was needed other than a JL catheter in 8 cases, while a right coronary angiogram was needed other than a JR catheter in 25 cases, showing that the right coronary artery (RCA) was mostly involved in difficult catheterizations. For left coronary angiograms, 4 cases hooked with TIG (1 case - posteriorly/low takeoff, 1 - high takeoff, 1 - mid-takeoff, and 1 - RCA/left main coronary artery [LMCA] from left sinus) and 4 cases with EBU catheter (1 - anterior/high takeoff, 2 - high takeoffs, and 1 - posteriorly/high takeoff). For right coronary angiograms, 21 cases hooked with TIG (3 cases - left sinus/anteriorly, 3 - high takeoff/anteriorly, 3 - low takeoff, 2 - mid takeoff/anteriorly, 3 - posterior/high takeoff, 1 - RCA/LMCA from left sinus, 1 - posteriorly/left sinus, 3 - high takeoff, 1 - anteriorly/low takeoff, and 1 - right sinus/mid-takeoff), 1 case with JRSH, 1 case with MPA (anterior/high takeoff) and 2 cases with NTR (1 - low takeoff and 1 - high takeoff). Conclusion: We found that the TIG catheter was useful in difficult femoral approach catheterizations in the majority of cases and it can be tried in difficult cases. Keywords: Anomalous coronary artery, catheterization, coronary angiogram, tiger, tiger catheter</abstract><pub>Medknow Publications and Media Pvt. Ltd</pub><doi>10.4103/jicc.jicc_33_23</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1561-8811
ispartof Journal of Indian College of Cardiology, 2024-01, Vol.14 (1), p.21-24
issn 1561-8811
2213-3615
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_3d75557d0e79406396b8b8de1d695ab0
source Medknow Open Access Journals
subjects Analysis
anomalous coronary artery
Catheterization
coronary angiogram
tiger
tiger catheter
title Tiger Catheter for Difficult Femoral Artery Approach Coronary Catheterization
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A01%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tiger%20Catheter%20for%20Difficult%20Femoral%20Artery%20Approach%20Coronary%20Catheterization&rft.jtitle=Journal%20of%20Indian%20College%20of%20Cardiology&rft.au=Nimmagadda,%20Satya&rft.date=2024-01-01&rft.volume=14&rft.issue=1&rft.spage=21&rft.epage=24&rft.pages=21-24&rft.issn=1561-8811&rft.eissn=2213-3615&rft_id=info:doi/10.4103/jicc.jicc_33_23&rft_dat=%3Cgale_doaj_%3EA815567514%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2813-49e55db45e345ae413eaeecde41520ec6219d45e58705f75869d792f09b748d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A815567514&rfr_iscdi=true