Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants

•Following the step by step described in this protocol is it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, and others.•Extracellular electrical signal measurements were associated to gas exchange measurement...

Full description

Saved in:
Bibliographic Details
Published in:MethodsX 2021-01, Vol.8, p.101214-101214, Article 101214
Main Authors: Macedo, Francynês da Conceiçao Oliveira, Daneluzzi, Gabriel Silva, Capelin, Diogo, Barbosa, Fábia da Silva, da Silva, Aldeir Ronaldo, de Oliveira, Ricardo Ferraz
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133
cites cdi_FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133
container_end_page 101214
container_issue
container_start_page 101214
container_title MethodsX
container_volume 8
creator Macedo, Francynês da Conceiçao Oliveira
Daneluzzi, Gabriel Silva
Capelin, Diogo
Barbosa, Fábia da Silva
da Silva, Aldeir Ronaldo
de Oliveira, Ricardo Ferraz
description •Following the step by step described in this protocol is it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, and others.•Extracellular electrical signal measurements were associated to gas exchange measurements using an infra-red gas analyzer (IRGA, model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology).•The technique is interesting to study electrical signaling in association with other physiological parameters in plants.•We present results that validate the protocol and discuss the troubleshooting that may compromise measurements and data collection. We present a detailed protocol for measuring extracellular electrical signals in plants using the electrode insertion technique. Using this approach, it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, burning, and others. Additionally, we describe how to associate gas exchange measurements using an infra-red gas analyzer (IRGA, Model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology) to measure extracellular electrical signals. • The method requires a complete electrical circuit that includes a measuring device (amplifier and voltmeter) and electrodes that provide a contact between the biological material and the equipment. • The infra-red gas analyzer (IRGA), needs to be grounded because it is an important source of noise for electrophysiological measurements. • The ZIM-probe did not cause any interference in electrical signal measure. • Our approach is useful for plant physiologists wishing to implement the technique of measuring electrical signals in plants, in association with other parameters of plant physiology. In addition, our text was written for agricultural and biological scientists who are not electronics specialists. [Display omitted]
doi_str_mv 10.1016/j.mex.2021.101214
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_3f60df74a2de4f0fae08e2aaf3ae6184</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2215016121000066</els_id><doaj_id>oai_doaj_org_article_3f60df74a2de4f0fae08e2aaf3ae6184</doaj_id><sourcerecordid>2564952096</sourcerecordid><originalsourceid>FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133</originalsourceid><addsrcrecordid>eNp9kU1r3DAQhk1oSUKaH5Cbjj10N_qy7KVQKCFtAoFemrMYyyNHi2w5kr0k_77yOpTm0pM-Zt5nmPctiitGt4wydb3f9viy5ZSz5c2ZPCnOOWflJhfZh3_uZ8VlSntKKRNSMMlPizMhpZCVqM6Lw-3z7MYeh4nA0JIxhimY4IkNkfQIaY54LAZL8GWKYND72UMk6NFM0RnwJLluAJ--kA5S7jJPMHR4xE1z7DJojJgWEnEDGT0MU_pUfLRZgpdv50Xx-OP2983d5uHXz_ub7w8bI3dy2sAOJUfa1JTzllJolAJeNrWsaksbhQZLLEuoGlNyahqrqMKyrSulKisqJsRFcb9y2wB7PUbXQ3zVAZw-foTYaYiTMx61yOrWVhJ4i9JSC0hr5ABWACpWy8z6trLGuemxNdmWCP4d9H1lcE-6Cwddi0qyWmXA5zdADM8zpkn3Li2GwoBhTpqXSu7yIrulla2tJoaUItq_YxjVS_x6r3P8eolfr_FnzddVg9nQg8Ook3E4GGxdzFnljd1_1H8APha5oA</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2564952096</pqid></control><display><type>article</type><title>Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants</title><source>PubMed Central(OpenAccess)</source><source>ScienceDirect (Online service)</source><creator>Macedo, Francynês da Conceiçao Oliveira ; Daneluzzi, Gabriel Silva ; Capelin, Diogo ; Barbosa, Fábia da Silva ; da Silva, Aldeir Ronaldo ; de Oliveira, Ricardo Ferraz</creator><creatorcontrib>Macedo, Francynês da Conceiçao Oliveira ; Daneluzzi, Gabriel Silva ; Capelin, Diogo ; Barbosa, Fábia da Silva ; da Silva, Aldeir Ronaldo ; de Oliveira, Ricardo Ferraz</creatorcontrib><description>•Following the step by step described in this protocol is it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, and others.•Extracellular electrical signal measurements were associated to gas exchange measurements using an infra-red gas analyzer (IRGA, model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology).•The technique is interesting to study electrical signaling in association with other physiological parameters in plants.•We present results that validate the protocol and discuss the troubleshooting that may compromise measurements and data collection. We present a detailed protocol for measuring extracellular electrical signals in plants using the electrode insertion technique. Using this approach, it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, burning, and others. Additionally, we describe how to associate gas exchange measurements using an infra-red gas analyzer (IRGA, Model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology) to measure extracellular electrical signals. • The method requires a complete electrical circuit that includes a measuring device (amplifier and voltmeter) and electrodes that provide a contact between the biological material and the equipment. • The infra-red gas analyzer (IRGA), needs to be grounded because it is an important source of noise for electrophysiological measurements. • The ZIM-probe did not cause any interference in electrical signal measure. • Our approach is useful for plant physiologists wishing to implement the technique of measuring electrical signals in plants, in association with other parameters of plant physiology. In addition, our text was written for agricultural and biological scientists who are not electronics specialists. [Display omitted]</description><identifier>ISSN: 2215-0161</identifier><identifier>EISSN: 2215-0161</identifier><identifier>DOI: 10.1016/j.mex.2021.101214</identifier><identifier>PMID: 34434737</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Electrophysiology ; Gas exchange ; Measurement protocol ; Protocol ; ZIM-probe</subject><ispartof>MethodsX, 2021-01, Vol.8, p.101214-101214, Article 101214</ispartof><rights>2021</rights><rights>2021 Published by Elsevier B.V. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133</citedby><cites>FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133</cites><orcidid>0000-0002-3459-851X ; 0000-0001-9709-9518</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC8374186/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2215016121000066$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,3549,27924,27925,45780,53791,53793</link.rule.ids></links><search><creatorcontrib>Macedo, Francynês da Conceiçao Oliveira</creatorcontrib><creatorcontrib>Daneluzzi, Gabriel Silva</creatorcontrib><creatorcontrib>Capelin, Diogo</creatorcontrib><creatorcontrib>Barbosa, Fábia da Silva</creatorcontrib><creatorcontrib>da Silva, Aldeir Ronaldo</creatorcontrib><creatorcontrib>de Oliveira, Ricardo Ferraz</creatorcontrib><title>Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants</title><title>MethodsX</title><description>•Following the step by step described in this protocol is it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, and others.•Extracellular electrical signal measurements were associated to gas exchange measurements using an infra-red gas analyzer (IRGA, model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology).•The technique is interesting to study electrical signaling in association with other physiological parameters in plants.•We present results that validate the protocol and discuss the troubleshooting that may compromise measurements and data collection. We present a detailed protocol for measuring extracellular electrical signals in plants using the electrode insertion technique. Using this approach, it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, burning, and others. Additionally, we describe how to associate gas exchange measurements using an infra-red gas analyzer (IRGA, Model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology) to measure extracellular electrical signals. • The method requires a complete electrical circuit that includes a measuring device (amplifier and voltmeter) and electrodes that provide a contact between the biological material and the equipment. • The infra-red gas analyzer (IRGA), needs to be grounded because it is an important source of noise for electrophysiological measurements. • The ZIM-probe did not cause any interference in electrical signal measure. • Our approach is useful for plant physiologists wishing to implement the technique of measuring electrical signals in plants, in association with other parameters of plant physiology. In addition, our text was written for agricultural and biological scientists who are not electronics specialists. [Display omitted]</description><subject>Electrophysiology</subject><subject>Gas exchange</subject><subject>Measurement protocol</subject><subject>Protocol</subject><subject>ZIM-probe</subject><issn>2215-0161</issn><issn>2215-0161</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kU1r3DAQhk1oSUKaH5Cbjj10N_qy7KVQKCFtAoFemrMYyyNHi2w5kr0k_77yOpTm0pM-Zt5nmPctiitGt4wydb3f9viy5ZSz5c2ZPCnOOWflJhfZh3_uZ8VlSntKKRNSMMlPizMhpZCVqM6Lw-3z7MYeh4nA0JIxhimY4IkNkfQIaY54LAZL8GWKYND72UMk6NFM0RnwJLluAJ--kA5S7jJPMHR4xE1z7DJojJgWEnEDGT0MU_pUfLRZgpdv50Xx-OP2983d5uHXz_ub7w8bI3dy2sAOJUfa1JTzllJolAJeNrWsaksbhQZLLEuoGlNyahqrqMKyrSulKisqJsRFcb9y2wB7PUbXQ3zVAZw-foTYaYiTMx61yOrWVhJ4i9JSC0hr5ABWACpWy8z6trLGuemxNdmWCP4d9H1lcE-6Cwddi0qyWmXA5zdADM8zpkn3Li2GwoBhTpqXSu7yIrulla2tJoaUItq_YxjVS_x6r3P8eolfr_FnzddVg9nQg8Ook3E4GGxdzFnljd1_1H8APha5oA</recordid><startdate>20210101</startdate><enddate>20210101</enddate><creator>Macedo, Francynês da Conceiçao Oliveira</creator><creator>Daneluzzi, Gabriel Silva</creator><creator>Capelin, Diogo</creator><creator>Barbosa, Fábia da Silva</creator><creator>da Silva, Aldeir Ronaldo</creator><creator>de Oliveira, Ricardo Ferraz</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-3459-851X</orcidid><orcidid>https://orcid.org/0000-0001-9709-9518</orcidid></search><sort><creationdate>20210101</creationdate><title>Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants</title><author>Macedo, Francynês da Conceiçao Oliveira ; Daneluzzi, Gabriel Silva ; Capelin, Diogo ; Barbosa, Fábia da Silva ; da Silva, Aldeir Ronaldo ; de Oliveira, Ricardo Ferraz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Electrophysiology</topic><topic>Gas exchange</topic><topic>Measurement protocol</topic><topic>Protocol</topic><topic>ZIM-probe</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Macedo, Francynês da Conceiçao Oliveira</creatorcontrib><creatorcontrib>Daneluzzi, Gabriel Silva</creatorcontrib><creatorcontrib>Capelin, Diogo</creatorcontrib><creatorcontrib>Barbosa, Fábia da Silva</creatorcontrib><creatorcontrib>da Silva, Aldeir Ronaldo</creatorcontrib><creatorcontrib>de Oliveira, Ricardo Ferraz</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>MethodsX</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Macedo, Francynês da Conceiçao Oliveira</au><au>Daneluzzi, Gabriel Silva</au><au>Capelin, Diogo</au><au>Barbosa, Fábia da Silva</au><au>da Silva, Aldeir Ronaldo</au><au>de Oliveira, Ricardo Ferraz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants</atitle><jtitle>MethodsX</jtitle><date>2021-01-01</date><risdate>2021</risdate><volume>8</volume><spage>101214</spage><epage>101214</epage><pages>101214-101214</pages><artnum>101214</artnum><issn>2215-0161</issn><eissn>2215-0161</eissn><abstract>•Following the step by step described in this protocol is it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, and others.•Extracellular electrical signal measurements were associated to gas exchange measurements using an infra-red gas analyzer (IRGA, model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology).•The technique is interesting to study electrical signaling in association with other physiological parameters in plants.•We present results that validate the protocol and discuss the troubleshooting that may compromise measurements and data collection. We present a detailed protocol for measuring extracellular electrical signals in plants using the electrode insertion technique. Using this approach, it is possible to measure long-distance electrical signaling induced by several stimuli, including wounding, current application, irrigation, burning, and others. Additionally, we describe how to associate gas exchange measurements using an infra-red gas analyzer (IRGA, Model Li-6400, Li-Cor) and turgor pressure measurements using a patch clamp pressure probe (ZIM-probe, YARA ZIM-plant Technology) to measure extracellular electrical signals. • The method requires a complete electrical circuit that includes a measuring device (amplifier and voltmeter) and electrodes that provide a contact between the biological material and the equipment. • The infra-red gas analyzer (IRGA), needs to be grounded because it is an important source of noise for electrophysiological measurements. • The ZIM-probe did not cause any interference in electrical signal measure. • Our approach is useful for plant physiologists wishing to implement the technique of measuring electrical signals in plants, in association with other parameters of plant physiology. In addition, our text was written for agricultural and biological scientists who are not electronics specialists. [Display omitted]</abstract><pub>Elsevier B.V</pub><pmid>34434737</pmid><doi>10.1016/j.mex.2021.101214</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-3459-851X</orcidid><orcidid>https://orcid.org/0000-0001-9709-9518</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2215-0161
ispartof MethodsX, 2021-01, Vol.8, p.101214-101214, Article 101214
issn 2215-0161
2215-0161
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_3f60df74a2de4f0fae08e2aaf3ae6184
source PubMed Central(OpenAccess); ScienceDirect (Online service)
subjects Electrophysiology
Gas exchange
Measurement protocol
Protocol
ZIM-probe
title Equipment and protocol for measurement of extracellular electrical signals, gas exchange and turgor pressure in plants
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T22%3A14%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Equipment%20and%20protocol%20for%20measurement%20of%20extracellular%20electrical%20signals,%20gas%20exchange%20and%20turgor%20pressure%20in%20plants&rft.jtitle=MethodsX&rft.au=Macedo,%20Francyn%C3%AAs%20da%20Concei%C3%A7ao%20Oliveira&rft.date=2021-01-01&rft.volume=8&rft.spage=101214&rft.epage=101214&rft.pages=101214-101214&rft.artnum=101214&rft.issn=2215-0161&rft.eissn=2215-0161&rft_id=info:doi/10.1016/j.mex.2021.101214&rft_dat=%3Cproquest_doaj_%3E2564952096%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c494t-a9e42e0b8022d00ab66a25b8478f0b6ece5e55a7bc520cbf606e5d87667f37133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2564952096&rft_id=info:pmid/34434737&rfr_iscdi=true