Loading…

Non-ischemic laparoscopic partial nephrectomy using 1318-nm diode laser for small exophytic renal tumors

Warm ischemia (WI) and bleeding constitute the main challenges for surgeons during laparoscopic partial nephrectomy (LPN). Current literature on the use of lasers for cutting and coagulation remains scarce and with small cohorts. We present the largest case series to date of non-ischemic LPN using a...

Full description

Saved in:
Bibliographic Details
Published in:BMC urology 2018-11, Vol.18 (1), p.99-99, Article 99
Main Authors: Drerup, Martin, Magdy, Ahmed, Hager, Martina, Colleselli, Daniela, Kunit, Thomas, Lusuardi, Lukas, Janetschek, Günter, Mitterberger, Michael
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Warm ischemia (WI) and bleeding constitute the main challenges for surgeons during laparoscopic partial nephrectomy (LPN). Current literature on the use of lasers for cutting and coagulation remains scarce and with small cohorts. We present the largest case series to date of non-ischemic LPN using a diode laser for small exophytic renal tumors. We retrospectively evaluated 29 patients with clinically localized exophytic renal tumors who underwent non-ischemic laser-assisted LPN with a 1318-nm wavelength diode laser. We started applying the laser 5 mm beyond the visible tumor margin, 5 mm away from the tissue in a non-contact fashion for coagulation and in direct contact with the parenchymal tissue for cutting.  RESULTS: The renal vessels were not clamped, resulting in a WIT (warm ischaemic time) of 0 min, except for one case that required warm ischemia for 12 min and parenchymal sutures. No transfusion was needed, with a mean Hemoglobin drop of 1,4 mg/dl and no postoperative complications. The eGFR did not significantly change by 6 months. Histologically, the majority of lesions (n = 22/29) were renal-cell carcinoma stage pT1a. The majority of malignant lesions (n = 13/22) had a negative margin. However, margin interpretation was difficult in 9 cases due to charring of the tumor base. A mean follow-up of 1.8 years revealed no tumor recurrence. The mean tumor diameter was 19.4 mm. The 1318-nm diode laser has the advantages of excellent cutting and sealing properties when applied to small vessels in the renal parenchyma, reducing the need for parenchymal sutures. However, excessive smoke, charring of the surgical margin, and inability to seal large blood vessels are encountered with this technique.
ISSN:1471-2490
1471-2490
DOI:10.1186/s12894-018-0405-9