Loading…

Performance of malaria microscopy external quality assessment and networking among health facilities in west Amhara region, Ethiopia

Microscopic examination of peripheral blood smear produces reliable results both about the malaria infection status and level of parasitemia. However, test results are affected by skill of the laboratory personnel, workload, condition of microscopes and quality of laboratory supplies. Therefore, con...

Full description

Saved in:
Bibliographic Details
Published in:BMC infectious diseases 2020-05, Vol.20 (1), p.355-355, Article 355
Main Authors: Tegegne, Banchamlak, Ejigu, Kefale, Alemu, Getaneh, Fetene, Yeshimebet, Endaylalu, Kindye, Melese, Mulatu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Microscopic examination of peripheral blood smear produces reliable results both about the malaria infection status and level of parasitemia. However, test results are affected by skill of the laboratory personnel, workload, condition of microscopes and quality of laboratory supplies. Therefore, continuous monitoring of the performance of laboratories is of pivotal importance in order to make timely correction. A facility based cross-sectional study was conducted from July 2017 to July 2019 to assess malaria microscopy performance among thirty malaria diagnostic laboratories in west Amhara region. Thirty slides were collected from participating laboratories every quarter. Collected slides were taken to Amhara Public Health Institute reference laboratory and re-checked by malaria microscopists who were blind to the results from health facilities. Percentage of test agreement, rates of false positive, false negative and species misdiagnosis were calculated using Excel 2010. Among a total of 6689 slides re-checked, results of 6146 slides were the same with that of participating laboratories. The test agreement was 97.31 and 94.6% for parasite detection and species identification, respectively. Variations in the overall performance of individual laboratories were seen within a range of 81.55 to 97.27% test agreement. Results of 543 (8.12%) slides were discordant, of which 363 (5.4%), 93 (1.4%) and 87 (1.3%) slides were due to species misdiagnosis, false positive and false negative results, respectively. There was good test agreement between participated laboratories and Amhara Public Health Institute. More accurate performance is expected as the country is tracking to malaria elimination. Hence, further strengthening the external quality assurance program is recommended.
ISSN:1471-2334
1471-2334
DOI:10.1186/s12879-020-05077-5