Loading…

Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis

We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach...

Full description

Saved in:
Bibliographic Details
Published in:Clinical ophthalmology (Auckland, N.Z.) N.Z.), 2016-01, Vol.10, p.2051-2053
Main Authors: Fawzy, Fathy, Wahba, Sherine S, Fawzy, Nader
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c576t-e34a56ecf7914ba03c82cda76a51e5ea279b67b3719f7c73a6d92b0369397f5f3
cites
container_end_page 2053
container_issue
container_start_page 2051
container_title Clinical ophthalmology (Auckland, N.Z.)
container_volume 10
creator Fawzy, Fathy
Wahba, Sherine S
Fawzy, Nader
description We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome.
doi_str_mv 10.2147/OPTH.S117306
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_4600d031e4a046c2a960c9c14531751c</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A506622526</galeid><doaj_id>oai_doaj_org_article_4600d031e4a046c2a960c9c14531751c</doaj_id><sourcerecordid>A506622526</sourcerecordid><originalsourceid>FETCH-LOGICAL-c576t-e34a56ecf7914ba03c82cda76a51e5ea279b67b3719f7c73a6d92b0369397f5f3</originalsourceid><addsrcrecordid>eNptkk1vEzEQhlcIREvhxhmthIQ4sMEfazu-IFUV0EpFRaJcuFgT7zhx8K5TexeJf49DQmgQ8sEf88xrz_itqueUzBht1dubz7eXsy-UKk7kg-q0LFQj2jl_eFhLdVI9yXlNiGRkrh5XJ0wprRWnp9W3T96maGHjQ4D0s85-OdTR1S7ApoZQdj0OY-2H2mE_xow2Dl0dIGNqIGefR-y20ezHqf6OCcbY-4BTiTytHjkIGZ_t57Pq64f3txeXzfXNx6uL8-vGCiXHBnkLQqJ1StN2AYTbObMdKAmCokBgSi-kWnBFtVNWcZCdZgvCpeZaOeH4WXW10-0irM0m-b4UYiJ48_sgpqWBNHob0LSSkI5wii2QVloGWhKrLW0Fp0pQW7Te7bQ206LHzpbaE4Qj0ePI4FdmGX8YQZQuLyoCr_cCKd5NmEfT-2yxNHfAOGVD51wQQktRBX35D7qOUxpKqwxjTHCi5pT9pZZQCvCDi-VeuxU154JIWUgmCzX7D1VGh70vX4aufMpxwqt7CSuEMK5yDNPo45CPwTc7sNgk54Tu0AxKzNaAZmtAszdgwV_cb-AB_uM4_gvPodQp</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2225307812</pqid></control><display><type>article</type><title>Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis</title><source>Taylor &amp; Francis</source><source>PubMed Central(OpenAccess)</source><source>Publicly Available Content (ProQuest)</source><creator>Fawzy, Fathy ; Wahba, Sherine S ; Fawzy, Nader</creator><creatorcontrib>Fawzy, Fathy ; Wahba, Sherine S ; Fawzy, Nader</creatorcontrib><description>We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome.</description><identifier>ISSN: 1177-5467</identifier><identifier>ISSN: 1177-5483</identifier><identifier>EISSN: 1177-5483</identifier><identifier>DOI: 10.2147/OPTH.S117306</identifier><identifier>PMID: 27799731</identifier><language>eng</language><publisher>New Zealand: Dove Medical Press Limited</publisher><subject>capillarity ; Cataracts ; Contact angle ; corneal flap alignment ; femtosecond LASIK flap ; Hypothesis ; Laser in situ keratomileusis ; Lasers ; Ophthalmology ; Porous materials ; Surgeons ; Tomography</subject><ispartof>Clinical ophthalmology (Auckland, N.Z.), 2016-01, Vol.10, p.2051-2053</ispartof><rights>COPYRIGHT 2016 Dove Medical Press Limited</rights><rights>2016. This work is licensed under https://creativecommons.org/licenses/by-nc/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2016 Fawzy et al. This work is published and licensed by Dove Medical Press Limited 2016</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c576t-e34a56ecf7914ba03c82cda76a51e5ea279b67b3719f7c73a6d92b0369397f5f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2225307812/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2225307812?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,25732,27903,27904,36991,36992,44569,53770,53772,74873</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/27799731$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Fawzy, Fathy</creatorcontrib><creatorcontrib>Wahba, Sherine S</creatorcontrib><creatorcontrib>Fawzy, Nader</creatorcontrib><title>Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis</title><title>Clinical ophthalmology (Auckland, N.Z.)</title><addtitle>Clin Ophthalmol</addtitle><description>We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome.</description><subject>capillarity</subject><subject>Cataracts</subject><subject>Contact angle</subject><subject>corneal flap alignment</subject><subject>femtosecond LASIK flap</subject><subject>Hypothesis</subject><subject>Laser in situ keratomileusis</subject><subject>Lasers</subject><subject>Ophthalmology</subject><subject>Porous materials</subject><subject>Surgeons</subject><subject>Tomography</subject><issn>1177-5467</issn><issn>1177-5483</issn><issn>1177-5483</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNptkk1vEzEQhlcIREvhxhmthIQ4sMEfazu-IFUV0EpFRaJcuFgT7zhx8K5TexeJf49DQmgQ8sEf88xrz_itqueUzBht1dubz7eXsy-UKk7kg-q0LFQj2jl_eFhLdVI9yXlNiGRkrh5XJ0wprRWnp9W3T96maGHjQ4D0s85-OdTR1S7ApoZQdj0OY-2H2mE_xow2Dl0dIGNqIGefR-y20ezHqf6OCcbY-4BTiTytHjkIGZ_t57Pq64f3txeXzfXNx6uL8-vGCiXHBnkLQqJ1StN2AYTbObMdKAmCokBgSi-kWnBFtVNWcZCdZgvCpeZaOeH4WXW10-0irM0m-b4UYiJ48_sgpqWBNHob0LSSkI5wii2QVloGWhKrLW0Fp0pQW7Te7bQ206LHzpbaE4Qj0ePI4FdmGX8YQZQuLyoCr_cCKd5NmEfT-2yxNHfAOGVD51wQQktRBX35D7qOUxpKqwxjTHCi5pT9pZZQCvCDi-VeuxU154JIWUgmCzX7D1VGh70vX4aufMpxwqt7CSuEMK5yDNPo45CPwTc7sNgk54Tu0AxKzNaAZmtAszdgwV_cb-AB_uM4_gvPodQp</recordid><startdate>20160101</startdate><enddate>20160101</enddate><creator>Fawzy, Fathy</creator><creator>Wahba, Sherine S</creator><creator>Fawzy, Nader</creator><general>Dove Medical Press Limited</general><general>Taylor &amp; Francis Ltd</general><general>Dove Medical Press</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8AO</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>K9.</scope><scope>M0S</scope><scope>M2O</scope><scope>MBDVC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20160101</creationdate><title>Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis</title><author>Fawzy, Fathy ; Wahba, Sherine S ; Fawzy, Nader</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c576t-e34a56ecf7914ba03c82cda76a51e5ea279b67b3719f7c73a6d92b0369397f5f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>capillarity</topic><topic>Cataracts</topic><topic>Contact angle</topic><topic>corneal flap alignment</topic><topic>femtosecond LASIK flap</topic><topic>Hypothesis</topic><topic>Laser in situ keratomileusis</topic><topic>Lasers</topic><topic>Ophthalmology</topic><topic>Porous materials</topic><topic>Surgeons</topic><topic>Tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fawzy, Fathy</creatorcontrib><creatorcontrib>Wahba, Sherine S</creatorcontrib><creatorcontrib>Fawzy, Nader</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection (Proquest)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest Pharma Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest Research Library</collection><collection>Research Library (Corporate)</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Clinical ophthalmology (Auckland, N.Z.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fawzy, Fathy</au><au>Wahba, Sherine S</au><au>Fawzy, Nader</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis</atitle><jtitle>Clinical ophthalmology (Auckland, N.Z.)</jtitle><addtitle>Clin Ophthalmol</addtitle><date>2016-01-01</date><risdate>2016</risdate><volume>10</volume><spage>2051</spage><epage>2053</epage><pages>2051-2053</pages><issn>1177-5467</issn><issn>1177-5483</issn><eissn>1177-5483</eissn><abstract>We present an observational sign that ensures perfect alignment during femtosecond laser-assisted in situ keratomileusis (FS LASIK). Alignment is assured when a microsponge is used to dry the flap and the area of dryness exceeds the area of direct touch of the microsponge. The area might even reach the whole circumference of the flap at the first touch. This sign of alignment can be explained by microcapillary action. This sign was not elicited in flaps created by a microkeratome.</abstract><cop>New Zealand</cop><pub>Dove Medical Press Limited</pub><pmid>27799731</pmid><doi>10.2147/OPTH.S117306</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1177-5467
ispartof Clinical ophthalmology (Auckland, N.Z.), 2016-01, Vol.10, p.2051-2053
issn 1177-5467
1177-5483
1177-5483
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_4600d031e4a046c2a960c9c14531751c
source Taylor & Francis; PubMed Central(OpenAccess); Publicly Available Content (ProQuest)
subjects capillarity
Cataracts
Contact angle
corneal flap alignment
femtosecond LASIK flap
Hypothesis
Laser in situ keratomileusis
Lasers
Ophthalmology
Porous materials
Surgeons
Tomography
title Microcapillary sign of flap alignment in femtosecond laser-assisted in situ keratomileusis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T20%3A06%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Microcapillary%20sign%20of%20flap%20alignment%20in%20femtosecond%20laser-assisted%20in%20situ%20keratomileusis&rft.jtitle=Clinical%20ophthalmology%20(Auckland,%20N.Z.)&rft.au=Fawzy,%20Fathy&rft.date=2016-01-01&rft.volume=10&rft.spage=2051&rft.epage=2053&rft.pages=2051-2053&rft.issn=1177-5467&rft.eissn=1177-5483&rft_id=info:doi/10.2147/OPTH.S117306&rft_dat=%3Cgale_doaj_%3EA506622526%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c576t-e34a56ecf7914ba03c82cda76a51e5ea279b67b3719f7c73a6d92b0369397f5f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2225307812&rft_id=info:pmid/27799731&rft_galeid=A506622526&rfr_iscdi=true