Glazed balconies impact on energy consumption of multi-story buildings

Through this research we have studied the influence of the closure of the balconies on the temperature and humidity. Three residential apartments with enclosed balconies are monitored simultaneously over two periods: a colder one in March and a warmer one in May providing an overview of the thermal...

Full description

Saved in:
Bibliographic Details
Published in:E3S web of conferences 2019-01, Vol.111, p.6079
Main Authors: Catalina, Tiberiu, Bortis, Daniel, Vartires, Andreea, Lungu, Cătălin
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Through this research we have studied the influence of the closure of the balconies on the temperature and humidity. Three residential apartments with enclosed balconies are monitored simultaneously over two periods: a colder one in March and a warmer one in May providing an overview of the thermal performance of a balcony relative to the interior. The results of the balcony#1 simulations made with the Trnsys 17 software show a good energy saving in the cold period, but higher cooling consumption in warm weather.The total energy demand difference between closed and open balconies is about 840 kWh. The simulation also showed us the close connection between the temperature in the balcony and the solar radiation that both grow and decrease simultaneously. At the end of the two campaigns, we came to the conclusion that a closed and thermally rehabilitated balcony is the best solution, being proven to have a winter advantage, the difference between the outdoor temperature and the balcony temperature being around 15 °C, but a summer disadvantage when temperatures in the balcony greatly increase and may exceed 50 °C, with the risk of overheating the balcony.
ISSN:2267-1242
2555-0403
2267-1242
DOI:10.1051/e3sconf/201911106079