Loading…

Flexural Strength Evaluation of Multi-Cell Composite L-Shaped Concrete-Filled Steel Tubular Beams

Concrete-filled steel tubular (CFST) members have been widely used in industrial structures and high-rise residential buildings. The multi-cell composite L-shaped concrete-filled steel tubular (ML-CFST) cross-section, as an innovative, special-shaped structural arrangement, may solve the issue of no...

Full description

Saved in:
Bibliographic Details
Published in:Buildings (Basel) 2022-01, Vol.12 (1), p.39
Main Authors: Shen, Yanfei, Tu, Yongqing, Huang, Wei
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Concrete-filled steel tubular (CFST) members have been widely used in industrial structures and high-rise residential buildings. The multi-cell composite L-shaped concrete-filled steel tubular (ML-CFST) cross-section, as an innovative, special-shaped structural arrangement, may solve the issue of normal CFST members protruding from walls and result in more usable interior space. Currently, no design rules are available for the application of ML-CFST members. One of the primary objectives of the present study is to develop recommendations in line with the unified theory to evaluate the bending moment resistance of ML-CFST beams. According to the unified theory, the bending moment resistance of an ML-CFST beam is related to the compressive strength (fsc) and the flexural strength index (γm) of a composite section, in which the accuracy of γm and fsc are affected by a confinement effect factor (ξ). Nevertheless, the original expression of ξ is not suitable for ML-CFST sections, since the appreciable effect of the irregular shape on confinement is neglected. Considering the cross-sectional geometry and boundary conditions of the cells, an equivalent shape factor to modify the confinement effect was proposed in this study through dividing the infill concrete into highly confined areas and less confined areas. An adequate formula to calculate the fsc and an approximate expression of γm for the ML-CFST sections was then developed. Furthermore, four-point bending tests on eight specimens were carried out to investigate the flexural performance of the ML-CFST beams. Lastly, the proposed formulas were assessed against experimental and numerical results. The comparisons show that the proposed unified theory-based approach produced accurate and generally conservative results for the ML-CFST beams studied.
ISSN:2075-5309
2075-5309