Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study

Background. The present study evaluates the success and efficacy of endotracheal intubation (ETI) using a modified intubation stylet and a magnet system to direct the stylet into the trachea. The system was developed by the researchers in an attempt to increase the success and efficacy of ETI. Metho...

Full description

Saved in:
Bibliographic Details
Published in:Emergency medicine international 2019, Vol.2019 (2019), p.1-7
Main Authors: Aydin, Attila, Aydin, Guclu, Acar, Yahya Ayhan, Tezel, Onur, Bilge, Sedat, Ozkan, Gokhan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c494t-591dd08f13e3f56071f26a89907ef33c54977e91bf95290118a6fda014f305033
container_end_page 7
container_issue 2019
container_start_page 1
container_title Emergency medicine international
container_volume 2019
creator Aydin, Attila
Aydin, Guclu
Acar, Yahya Ayhan
Tezel, Onur
Bilge, Sedat
Ozkan, Gokhan
description Background. The present study evaluates the success and efficacy of endotracheal intubation (ETI) using a modified intubation stylet and a magnet system to direct the stylet into the trachea. The system was developed by the researchers in an attempt to increase the success and efficacy of ETI. Methods. ETI procedures were performed on an airway management manikin by emergency medical technicians with at least four years of experience in ETI. The technicians used a stylet modified with an iron ball affixed to the tip and a neodymium magnet, designed specifically for the study. The intention was to guide the endotracheal tube into the trachea at the level of the thyroid and cricoid cartilages on the manikin with the aid of the modified stylet and the magnetic force of the neodymium magnet. The success rate, completion time, and degree of difficulty of two procedures were compared: magnetic endotracheal intubation (METI) and classic ETI (CETI). Results. The success rate was 100% in both groups. The mean completion times for the METI and CETI procedures were 18.31 ± 2.46 s and 20.01 ± 1.95 s, respectively. There were significant differences in completion time and degree of difficulty between the METI and CETI procedures (both p=0.001). Conclusions. We found the use of a neodymium magnet and modified stylet to be an effective method to guide the endotracheal tube into the trachea. The present study may provide a basis for future studies.
doi_str_mv 10.1155/2019/5804260
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_4e964182464c49099e1b19f446371e85</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A608073256</galeid><doaj_id>oai_doaj_org_article_4e964182464c49099e1b19f446371e85</doaj_id><sourcerecordid>A608073256</sourcerecordid><originalsourceid>FETCH-LOGICAL-c494t-591dd08f13e3f56071f26a89907ef33c54977e91bf95290118a6fda014f305033</originalsourceid><addsrcrecordid>eNqNkl1v0zAUhiMEYtPYHdfIEhJCot38FSfmAqkqAyptMDF2bbnxceuR2CVxOpWfwy_FWUdZJS5ILhIdP37inPNm2XOCTwjJ81OKiTzNS8ypwI-yQ4olHtMyl4937xwfZMddd4PTlWMsJX-aHTBSsIIJcZj9OvMmxFZXS9A1mvnYz3V0waP5Bl3qVjdgXNWh6875BfoMwWwa1zfoQi88RKS9QRfBOOvAoKu4qVPNeXTlmr7WMdXeO2td1dcRTVx7qzdv0QRdtqFbQRXdGkboa1KExv0EM0LTtNCFNbRJ7933QRR7s3mWPbG67uD4_nmUXX84-zb9ND7_8nE2nZyPKy55HOeSGINLSxgwmwtcEEuFLqXEBVjGqpzLogBJ5lbmVGJCSi2s0Zhwy1JnGDvKZluvCfpGrVrX6HajgnbqrhDahdJtdFUNioMUnJSUC54-npoKZE6k5VywgkCZJ9e7rWvVz1MLK_Cpx_WedH_Fu6VahLUSJUln50nw-l7Qhh89dFE1rqugrrWH0HeKsjR-WkhWJvTlFl3odDTn7d08B1xNBC5xwWguEnXyDyrdBhpXBQ_WpfrehlcPNgzxiMsu1P2Qjm4fHG3BaphfC3b3mwSrIaVqSKm6T2nCXzxszQ7-k8kEvNkCS-eNvnX_qYPEgNV_aZJTyjn7Db8A9xI</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2315527938</pqid></control><display><type>article</type><title>Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study</title><source>Wiley Online Library Open Access</source><source>PubMed Central(OpenAccess)</source><creator>Aydin, Attila ; Aydin, Guclu ; Acar, Yahya Ayhan ; Tezel, Onur ; Bilge, Sedat ; Ozkan, Gokhan</creator><contributor>Avner, Jeffrey R.</contributor><creatorcontrib>Aydin, Attila ; Aydin, Guclu ; Acar, Yahya Ayhan ; Tezel, Onur ; Bilge, Sedat ; Ozkan, Gokhan ; Avner, Jeffrey R.</creatorcontrib><description>Background. The present study evaluates the success and efficacy of endotracheal intubation (ETI) using a modified intubation stylet and a magnet system to direct the stylet into the trachea. The system was developed by the researchers in an attempt to increase the success and efficacy of ETI. Methods. ETI procedures were performed on an airway management manikin by emergency medical technicians with at least four years of experience in ETI. The technicians used a stylet modified with an iron ball affixed to the tip and a neodymium magnet, designed specifically for the study. The intention was to guide the endotracheal tube into the trachea at the level of the thyroid and cricoid cartilages on the manikin with the aid of the modified stylet and the magnetic force of the neodymium magnet. The success rate, completion time, and degree of difficulty of two procedures were compared: magnetic endotracheal intubation (METI) and classic ETI (CETI). Results. The success rate was 100% in both groups. The mean completion times for the METI and CETI procedures were 18.31 ± 2.46 s and 20.01 ± 1.95 s, respectively. There were significant differences in completion time and degree of difficulty between the METI and CETI procedures (both p=0.001). Conclusions. We found the use of a neodymium magnet and modified stylet to be an effective method to guide the endotracheal tube into the trachea. The present study may provide a basis for future studies.</description><identifier>ISSN: 2090-2840</identifier><identifier>EISSN: 2090-2859</identifier><identifier>DOI: 10.1155/2019/5804260</identifier><identifier>PMID: 31737366</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Publishing Corporation</publisher><subject>Magnetic alloys ; Magnetic fields ; Medical personnel</subject><ispartof>Emergency medicine international, 2019, Vol.2019 (2019), p.1-7</ispartof><rights>Copyright © 2019 Sedat Bilge et al.</rights><rights>COPYRIGHT 2019 John Wiley &amp; Sons, Inc.</rights><rights>Copyright © 2019 Sedat Bilge et al. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c494t-591dd08f13e3f56071f26a89907ef33c54977e91bf95290118a6fda014f305033</cites><orcidid>0000-0002-0669-2859 ; 0000-0002-9572-5738</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815604/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6815604/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,4024,27923,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31737366$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Avner, Jeffrey R.</contributor><creatorcontrib>Aydin, Attila</creatorcontrib><creatorcontrib>Aydin, Guclu</creatorcontrib><creatorcontrib>Acar, Yahya Ayhan</creatorcontrib><creatorcontrib>Tezel, Onur</creatorcontrib><creatorcontrib>Bilge, Sedat</creatorcontrib><creatorcontrib>Ozkan, Gokhan</creatorcontrib><title>Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study</title><title>Emergency medicine international</title><addtitle>Emerg Med Int</addtitle><description>Background. The present study evaluates the success and efficacy of endotracheal intubation (ETI) using a modified intubation stylet and a magnet system to direct the stylet into the trachea. The system was developed by the researchers in an attempt to increase the success and efficacy of ETI. Methods. ETI procedures were performed on an airway management manikin by emergency medical technicians with at least four years of experience in ETI. The technicians used a stylet modified with an iron ball affixed to the tip and a neodymium magnet, designed specifically for the study. The intention was to guide the endotracheal tube into the trachea at the level of the thyroid and cricoid cartilages on the manikin with the aid of the modified stylet and the magnetic force of the neodymium magnet. The success rate, completion time, and degree of difficulty of two procedures were compared: magnetic endotracheal intubation (METI) and classic ETI (CETI). Results. The success rate was 100% in both groups. The mean completion times for the METI and CETI procedures were 18.31 ± 2.46 s and 20.01 ± 1.95 s, respectively. There were significant differences in completion time and degree of difficulty between the METI and CETI procedures (both p=0.001). Conclusions. We found the use of a neodymium magnet and modified stylet to be an effective method to guide the endotracheal tube into the trachea. The present study may provide a basis for future studies.</description><subject>Magnetic alloys</subject><subject>Magnetic fields</subject><subject>Medical personnel</subject><issn>2090-2840</issn><issn>2090-2859</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNqNkl1v0zAUhiMEYtPYHdfIEhJCot38FSfmAqkqAyptMDF2bbnxceuR2CVxOpWfwy_FWUdZJS5ILhIdP37inPNm2XOCTwjJ81OKiTzNS8ypwI-yQ4olHtMyl4937xwfZMddd4PTlWMsJX-aHTBSsIIJcZj9OvMmxFZXS9A1mvnYz3V0waP5Bl3qVjdgXNWh6875BfoMwWwa1zfoQi88RKS9QRfBOOvAoKu4qVPNeXTlmr7WMdXeO2td1dcRTVx7qzdv0QRdtqFbQRXdGkboa1KExv0EM0LTtNCFNbRJ7933QRR7s3mWPbG67uD4_nmUXX84-zb9ND7_8nE2nZyPKy55HOeSGINLSxgwmwtcEEuFLqXEBVjGqpzLogBJ5lbmVGJCSi2s0Zhwy1JnGDvKZluvCfpGrVrX6HajgnbqrhDahdJtdFUNioMUnJSUC54-npoKZE6k5VywgkCZJ9e7rWvVz1MLK_Cpx_WedH_Fu6VahLUSJUln50nw-l7Qhh89dFE1rqugrrWH0HeKsjR-WkhWJvTlFl3odDTn7d08B1xNBC5xwWguEnXyDyrdBhpXBQ_WpfrehlcPNgzxiMsu1P2Qjm4fHG3BaphfC3b3mwSrIaVqSKm6T2nCXzxszQ7-k8kEvNkCS-eNvnX_qYPEgNV_aZJTyjn7Db8A9xI</recordid><startdate>2019</startdate><enddate>2019</enddate><creator>Aydin, Attila</creator><creator>Aydin, Guclu</creator><creator>Acar, Yahya Ayhan</creator><creator>Tezel, Onur</creator><creator>Bilge, Sedat</creator><creator>Ozkan, Gokhan</creator><general>Hindawi Publishing Corporation</general><general>Hindawi</general><general>John Wiley &amp; Sons, Inc</general><general>Hindawi Limited</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-0669-2859</orcidid><orcidid>https://orcid.org/0000-0002-9572-5738</orcidid></search><sort><creationdate>2019</creationdate><title>Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study</title><author>Aydin, Attila ; Aydin, Guclu ; Acar, Yahya Ayhan ; Tezel, Onur ; Bilge, Sedat ; Ozkan, Gokhan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c494t-591dd08f13e3f56071f26a89907ef33c54977e91bf95290118a6fda014f305033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Magnetic alloys</topic><topic>Magnetic fields</topic><topic>Medical personnel</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Aydin, Attila</creatorcontrib><creatorcontrib>Aydin, Guclu</creatorcontrib><creatorcontrib>Acar, Yahya Ayhan</creatorcontrib><creatorcontrib>Tezel, Onur</creatorcontrib><creatorcontrib>Bilge, Sedat</creatorcontrib><creatorcontrib>Ozkan, Gokhan</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Emergency medicine international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Aydin, Attila</au><au>Aydin, Guclu</au><au>Acar, Yahya Ayhan</au><au>Tezel, Onur</au><au>Bilge, Sedat</au><au>Ozkan, Gokhan</au><au>Avner, Jeffrey R.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study</atitle><jtitle>Emergency medicine international</jtitle><addtitle>Emerg Med Int</addtitle><date>2019</date><risdate>2019</risdate><volume>2019</volume><issue>2019</issue><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>2090-2840</issn><eissn>2090-2859</eissn><abstract>Background. The present study evaluates the success and efficacy of endotracheal intubation (ETI) using a modified intubation stylet and a magnet system to direct the stylet into the trachea. The system was developed by the researchers in an attempt to increase the success and efficacy of ETI. Methods. ETI procedures were performed on an airway management manikin by emergency medical technicians with at least four years of experience in ETI. The technicians used a stylet modified with an iron ball affixed to the tip and a neodymium magnet, designed specifically for the study. The intention was to guide the endotracheal tube into the trachea at the level of the thyroid and cricoid cartilages on the manikin with the aid of the modified stylet and the magnetic force of the neodymium magnet. The success rate, completion time, and degree of difficulty of two procedures were compared: magnetic endotracheal intubation (METI) and classic ETI (CETI). Results. The success rate was 100% in both groups. The mean completion times for the METI and CETI procedures were 18.31 ± 2.46 s and 20.01 ± 1.95 s, respectively. There were significant differences in completion time and degree of difficulty between the METI and CETI procedures (both p=0.001). Conclusions. We found the use of a neodymium magnet and modified stylet to be an effective method to guide the endotracheal tube into the trachea. The present study may provide a basis for future studies.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Publishing Corporation</pub><pmid>31737366</pmid><doi>10.1155/2019/5804260</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0002-0669-2859</orcidid><orcidid>https://orcid.org/0000-0002-9572-5738</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2090-2840
ispartof Emergency medicine international, 2019, Vol.2019 (2019), p.1-7
issn 2090-2840
2090-2859
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_4e964182464c49099e1b19f446371e85
source Wiley Online Library Open Access; PubMed Central(OpenAccess)
subjects Magnetic alloys
Magnetic fields
Medical personnel
title Endotracheal Intubation by Paramedics Using Neodymium Magnet and Modified Stylet in Simulated Difficult Airway: A Prospective, Randomized, Crossover Manikin Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T16%3A13%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endotracheal%20Intubation%20by%20Paramedics%20Using%20Neodymium%20Magnet%20and%20Modified%20Stylet%20in%20Simulated%20Difficult%20Airway:%20A%20Prospective,%20Randomized,%20Crossover%20Manikin%20Study&rft.jtitle=Emergency%20medicine%20international&rft.au=Aydin,%20Attila&rft.date=2019&rft.volume=2019&rft.issue=2019&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=2090-2840&rft.eissn=2090-2859&rft_id=info:doi/10.1155/2019/5804260&rft_dat=%3Cgale_doaj_%3EA608073256%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c494t-591dd08f13e3f56071f26a89907ef33c54977e91bf95290118a6fda014f305033%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2315527938&rft_id=info:pmid/31737366&rft_galeid=A608073256&rfr_iscdi=true