Loading…
Optical Surface-guided Radiation Therapy for Upper and Lower Limb Sarcomas: An Analysis of Setup Errors and Clinical Target Volume-To-Planning Target Volume Margins
To assess the clinical benefits of surface-guided radiation therapy (SGRT) in terms of setup error, positioning time, and clinical target volume-to-planning target volume (CTV-PTV) margin in extremity soft tissue sarcoma (STS). Fifty consecutive patients treated with radiation therapy were selected...
Saved in:
Published in: | Advances in radiation oncology 2024-08, Vol.9 (8), p.101526, Article 101526 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To assess the clinical benefits of surface-guided radiation therapy (SGRT) in terms of setup error, positioning time, and clinical target volume-to-planning target volume (CTV-PTV) margin in extremity soft tissue sarcoma (STS).
Fifty consecutive patients treated with radiation therapy were selected retrospectively. Treatment setup was performed with either laser-based imaging only (control group), or with laser-based and daily optical surface-based imaging (SGRT group). Pretreatment cone beam computed tomography images were acquired daily for the first 3 to 5 fractions and weekly thereafter, with the frequency adjusted as necessary. Translational and rotational errors were collected. CTV-PTV margin was calculated using the formula, 2.5Σ + 0.7σ.
Each group consisted of 10 and 15 upper and lower limb STSs, respectively. For patients with upper limb sarcomas, the translation errors were 1.64 ± 1.34 mm, 1.10 ± 1.50 mm, and 1.24 ± 1.45 mm in the SGRT group, and 1.48 ± 3.16 mm, 2.84 ± 2.85 mm, and 3.14 ± 3.29 mm in control group in the left-right, supero-inferior, and antero-posterior directions, respectively. Correspondingly, for patients with lower limb sarcomas, the translation errors were 1.21 ± 1.65 mm, 1.39 ± 1.71 mm, and 1.48 ± 2.10 mm in the SGRT group, and 1.81 ± 2.60 mm, 2.93 ± 3.28 mm, and 3.53 ± 3.75 mm in control group, respectively. The calculated CTV-PTV margins of the SGRT group and control group were 5.0, 3.8, 4.1 versus 5.9, 9.1, 10.1 mm for upper limb sarcomas; and 4.2, 4.7, 5.2 mm versus 6.3, 9.6, and 11.4 mm for lower limb sarcomas in the left-right, supero-inferior, and antero-posterior directions, respectively.
Daily optical surface guidance can effectively improve the setup accuracy of extremity STS patients, and safely reduce the required CTV-PTV margins. |
---|---|
ISSN: | 2452-1094 2452-1094 |
DOI: | 10.1016/j.adro.2024.101526 |