Loading…

Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules

This study aimed to develop radiomic models based on low-dose CT (LDCT) and standard-dose CT to distinguish adenocarcinomas from benign lesions in patients with solid solitary pulmonary nodules and compare the performance among these radiomic models and Lung CT Screening Reporting and Data System (L...

Full description

Saved in:
Bibliographic Details
Published in:Frontiers in oncology 2021-02, Vol.10, p.634298-634298
Main Authors: Liu, Jieke, Xu, Hao, Qing, Haomiao, Li, Yong, Yang, Xi, He, Changjiu, Ren, Jing, Zhou, Peng
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23
cites cdi_FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23
container_end_page 634298
container_issue
container_start_page 634298
container_title Frontiers in oncology
container_volume 10
creator Liu, Jieke
Xu, Hao
Qing, Haomiao
Li, Yong
Yang, Xi
He, Changjiu
Ren, Jing
Zhou, Peng
description This study aimed to develop radiomic models based on low-dose CT (LDCT) and standard-dose CT to distinguish adenocarcinomas from benign lesions in patients with solid solitary pulmonary nodules and compare the performance among these radiomic models and Lung CT Screening Reporting and Data System (Lung-RADS). The reproducibility of radiomic features between LDCT and standard-dose CT were also evaluated. A total of 141 consecutive pathologically confirmed solid solitary pulmonary nodules were enrolled including 50 adenocarcinomas and 48 benign nodules in primary cohort and 22 adenocarcinomas and 21 benign nodules in validation cohort. LDCT and standard-dose CT scans were conducted using same acquisition parameters and reconstruction method except for radiation dose. All nodules were automatically segmented and 104 original radiomic features were extracted. The concordance correlation coefficient was used to quantify reproducibility of radiomic features between LDCT and standard-dose CT. Radiomic features were selected to build radiomic signature, and clinical characteristics and radiomic signature were combined to develop radiomic nomogram for LDCT and standard-dose CT, respectively. The performance of radiomic models and Lung-RADS was assessed by area under curve (AUC) of receiver operating characteristic curve, sensitivity, and specificity. Shape and first order features, and neighboring gray tone difference matrix features were highly reproducible between LDCT and standard-dose CT. No significant differences of AUCs were found among radiomic signature and nomogram of LDCT and standard-dose CT in both primary and validation cohort (0.915 0.919 0.898 0.909 and 0.976 0.976 0.985 0.987, respectively). These radiomic models had higher specificity than Lung-RADS (all correct < 0.05), while there were no significant differences of sensitivity between Lung-RADS and radiomic models. The diagnostic performance of LDCT-based radiomic models to differentiate adenocarcinomas from benign lesions in solid pulmonary nodules were equivalent to that of standard-dose CT. The LDCT-based radiomic model with higher specificity and lower false-positive rate than Lung-RADS might help reduce overdiagnosis and overtreatment of solid pulmonary nodules in lung cancer screening.
doi_str_mv 10.3389/fonc.2020.634298
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_545dc99876844ebba2ea8d8d77f819c9</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_545dc99876844ebba2ea8d8d77f819c9</doaj_id><sourcerecordid>2491943281</sourcerecordid><originalsourceid>FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23</originalsourceid><addsrcrecordid>eNpVkktv1DAUhSMEolXpnhXykk0Gv5LYG6R2oFBpgIrOgp3l-DG4SnwHOwH1f_CD8TSlar2wrXvP-Xwln6p6TfCKMSHfeYhmRTHFq5ZxKsWz6phSxmvJ2Y_nj-5H1WnON7istsEEs5fVEWMt5gyz4-rvGsa9TiFDRODRd20DjMGgL2DdkNG5zs6i0tvAn_oDZId0tOh6KrtOdqmst8hDQlfJ2WCmsIDOrItgdDIhwqjzne3cxbArKJeLKKMQ0TUMwaKreRgh6nSLvoKdB5dfVS-8HrI7vT9Pqu3Fx-36c7359ulyfbapDW_pVBPPhWeS2VZz5o1oCDNYWO37hnWNEz32HmPRNsS0zMiud5hw03LXe2p7yk6qywVrQd-ofQpjmUGBDuquAGmndJqCGZxqeGONlKJrBS_-XlOnhRW267wg0sjCer-w9nM_OmtcnJIenkCfdmL4qXbwW3VC8K45AN7eAxL8ml2e1BiyccOgo4M5K8olKb9JBSlSvEhNgpyT8w_PEKwO0VCHaKhDNNQSjWJ583i8B8P_ILB_tDK3oA</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2491943281</pqid></control><display><type>article</type><title>Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules</title><source>PubMed (Medline)</source><creator>Liu, Jieke ; Xu, Hao ; Qing, Haomiao ; Li, Yong ; Yang, Xi ; He, Changjiu ; Ren, Jing ; Zhou, Peng</creator><creatorcontrib>Liu, Jieke ; Xu, Hao ; Qing, Haomiao ; Li, Yong ; Yang, Xi ; He, Changjiu ; Ren, Jing ; Zhou, Peng</creatorcontrib><description>This study aimed to develop radiomic models based on low-dose CT (LDCT) and standard-dose CT to distinguish adenocarcinomas from benign lesions in patients with solid solitary pulmonary nodules and compare the performance among these radiomic models and Lung CT Screening Reporting and Data System (Lung-RADS). The reproducibility of radiomic features between LDCT and standard-dose CT were also evaluated. A total of 141 consecutive pathologically confirmed solid solitary pulmonary nodules were enrolled including 50 adenocarcinomas and 48 benign nodules in primary cohort and 22 adenocarcinomas and 21 benign nodules in validation cohort. LDCT and standard-dose CT scans were conducted using same acquisition parameters and reconstruction method except for radiation dose. All nodules were automatically segmented and 104 original radiomic features were extracted. The concordance correlation coefficient was used to quantify reproducibility of radiomic features between LDCT and standard-dose CT. Radiomic features were selected to build radiomic signature, and clinical characteristics and radiomic signature were combined to develop radiomic nomogram for LDCT and standard-dose CT, respectively. The performance of radiomic models and Lung-RADS was assessed by area under curve (AUC) of receiver operating characteristic curve, sensitivity, and specificity. Shape and first order features, and neighboring gray tone difference matrix features were highly reproducible between LDCT and standard-dose CT. No significant differences of AUCs were found among radiomic signature and nomogram of LDCT and standard-dose CT in both primary and validation cohort (0.915 0.919 0.898 0.909 and 0.976 0.976 0.985 0.987, respectively). These radiomic models had higher specificity than Lung-RADS (all correct &lt; 0.05), while there were no significant differences of sensitivity between Lung-RADS and radiomic models. The diagnostic performance of LDCT-based radiomic models to differentiate adenocarcinomas from benign lesions in solid pulmonary nodules were equivalent to that of standard-dose CT. The LDCT-based radiomic model with higher specificity and lower false-positive rate than Lung-RADS might help reduce overdiagnosis and overtreatment of solid pulmonary nodules in lung cancer screening.</description><identifier>ISSN: 2234-943X</identifier><identifier>EISSN: 2234-943X</identifier><identifier>DOI: 10.3389/fonc.2020.634298</identifier><identifier>PMID: 33604303</identifier><language>eng</language><publisher>Switzerland: Frontiers Media S.A</publisher><subject>benign lesion ; low-dose computed tomography ; lung adenocarcinoma ; lung cancer screening ; Oncology ; radiomics ; solid pulmonary nodule</subject><ispartof>Frontiers in oncology, 2021-02, Vol.10, p.634298-634298</ispartof><rights>Copyright © 2021 Liu, Xu, Qing, Li, Yang, He, Ren and Zhou.</rights><rights>Copyright © 2021 Liu, Xu, Qing, Li, Yang, He, Ren and Zhou 2021 Liu, Xu, Qing, Li, Yang, He, Ren and Zhou</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23</citedby><cites>FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7884759/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7884759/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33604303$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Liu, Jieke</creatorcontrib><creatorcontrib>Xu, Hao</creatorcontrib><creatorcontrib>Qing, Haomiao</creatorcontrib><creatorcontrib>Li, Yong</creatorcontrib><creatorcontrib>Yang, Xi</creatorcontrib><creatorcontrib>He, Changjiu</creatorcontrib><creatorcontrib>Ren, Jing</creatorcontrib><creatorcontrib>Zhou, Peng</creatorcontrib><title>Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules</title><title>Frontiers in oncology</title><addtitle>Front Oncol</addtitle><description>This study aimed to develop radiomic models based on low-dose CT (LDCT) and standard-dose CT to distinguish adenocarcinomas from benign lesions in patients with solid solitary pulmonary nodules and compare the performance among these radiomic models and Lung CT Screening Reporting and Data System (Lung-RADS). The reproducibility of radiomic features between LDCT and standard-dose CT were also evaluated. A total of 141 consecutive pathologically confirmed solid solitary pulmonary nodules were enrolled including 50 adenocarcinomas and 48 benign nodules in primary cohort and 22 adenocarcinomas and 21 benign nodules in validation cohort. LDCT and standard-dose CT scans were conducted using same acquisition parameters and reconstruction method except for radiation dose. All nodules were automatically segmented and 104 original radiomic features were extracted. The concordance correlation coefficient was used to quantify reproducibility of radiomic features between LDCT and standard-dose CT. Radiomic features were selected to build radiomic signature, and clinical characteristics and radiomic signature were combined to develop radiomic nomogram for LDCT and standard-dose CT, respectively. The performance of radiomic models and Lung-RADS was assessed by area under curve (AUC) of receiver operating characteristic curve, sensitivity, and specificity. Shape and first order features, and neighboring gray tone difference matrix features were highly reproducible between LDCT and standard-dose CT. No significant differences of AUCs were found among radiomic signature and nomogram of LDCT and standard-dose CT in both primary and validation cohort (0.915 0.919 0.898 0.909 and 0.976 0.976 0.985 0.987, respectively). These radiomic models had higher specificity than Lung-RADS (all correct &lt; 0.05), while there were no significant differences of sensitivity between Lung-RADS and radiomic models. The diagnostic performance of LDCT-based radiomic models to differentiate adenocarcinomas from benign lesions in solid pulmonary nodules were equivalent to that of standard-dose CT. The LDCT-based radiomic model with higher specificity and lower false-positive rate than Lung-RADS might help reduce overdiagnosis and overtreatment of solid pulmonary nodules in lung cancer screening.</description><subject>benign lesion</subject><subject>low-dose computed tomography</subject><subject>lung adenocarcinoma</subject><subject>lung cancer screening</subject><subject>Oncology</subject><subject>radiomics</subject><subject>solid pulmonary nodule</subject><issn>2234-943X</issn><issn>2234-943X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkktv1DAUhSMEolXpnhXykk0Gv5LYG6R2oFBpgIrOgp3l-DG4SnwHOwH1f_CD8TSlar2wrXvP-Xwln6p6TfCKMSHfeYhmRTHFq5ZxKsWz6phSxmvJ2Y_nj-5H1WnON7istsEEs5fVEWMt5gyz4-rvGsa9TiFDRODRd20DjMGgL2DdkNG5zs6i0tvAn_oDZId0tOh6KrtOdqmst8hDQlfJ2WCmsIDOrItgdDIhwqjzne3cxbArKJeLKKMQ0TUMwaKreRgh6nSLvoKdB5dfVS-8HrI7vT9Pqu3Fx-36c7359ulyfbapDW_pVBPPhWeS2VZz5o1oCDNYWO37hnWNEz32HmPRNsS0zMiud5hw03LXe2p7yk6qywVrQd-ofQpjmUGBDuquAGmndJqCGZxqeGONlKJrBS_-XlOnhRW267wg0sjCer-w9nM_OmtcnJIenkCfdmL4qXbwW3VC8K45AN7eAxL8ml2e1BiyccOgo4M5K8olKb9JBSlSvEhNgpyT8w_PEKwO0VCHaKhDNNQSjWJ583i8B8P_ILB_tDK3oA</recordid><startdate>20210202</startdate><enddate>20210202</enddate><creator>Liu, Jieke</creator><creator>Xu, Hao</creator><creator>Qing, Haomiao</creator><creator>Li, Yong</creator><creator>Yang, Xi</creator><creator>He, Changjiu</creator><creator>Ren, Jing</creator><creator>Zhou, Peng</creator><general>Frontiers Media S.A</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20210202</creationdate><title>Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules</title><author>Liu, Jieke ; Xu, Hao ; Qing, Haomiao ; Li, Yong ; Yang, Xi ; He, Changjiu ; Ren, Jing ; Zhou, Peng</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>benign lesion</topic><topic>low-dose computed tomography</topic><topic>lung adenocarcinoma</topic><topic>lung cancer screening</topic><topic>Oncology</topic><topic>radiomics</topic><topic>solid pulmonary nodule</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Liu, Jieke</creatorcontrib><creatorcontrib>Xu, Hao</creatorcontrib><creatorcontrib>Qing, Haomiao</creatorcontrib><creatorcontrib>Li, Yong</creatorcontrib><creatorcontrib>Yang, Xi</creatorcontrib><creatorcontrib>He, Changjiu</creatorcontrib><creatorcontrib>Ren, Jing</creatorcontrib><creatorcontrib>Zhou, Peng</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>Directory of Open Access Journals</collection><jtitle>Frontiers in oncology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Liu, Jieke</au><au>Xu, Hao</au><au>Qing, Haomiao</au><au>Li, Yong</au><au>Yang, Xi</au><au>He, Changjiu</au><au>Ren, Jing</au><au>Zhou, Peng</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules</atitle><jtitle>Frontiers in oncology</jtitle><addtitle>Front Oncol</addtitle><date>2021-02-02</date><risdate>2021</risdate><volume>10</volume><spage>634298</spage><epage>634298</epage><pages>634298-634298</pages><issn>2234-943X</issn><eissn>2234-943X</eissn><abstract>This study aimed to develop radiomic models based on low-dose CT (LDCT) and standard-dose CT to distinguish adenocarcinomas from benign lesions in patients with solid solitary pulmonary nodules and compare the performance among these radiomic models and Lung CT Screening Reporting and Data System (Lung-RADS). The reproducibility of radiomic features between LDCT and standard-dose CT were also evaluated. A total of 141 consecutive pathologically confirmed solid solitary pulmonary nodules were enrolled including 50 adenocarcinomas and 48 benign nodules in primary cohort and 22 adenocarcinomas and 21 benign nodules in validation cohort. LDCT and standard-dose CT scans were conducted using same acquisition parameters and reconstruction method except for radiation dose. All nodules were automatically segmented and 104 original radiomic features were extracted. The concordance correlation coefficient was used to quantify reproducibility of radiomic features between LDCT and standard-dose CT. Radiomic features were selected to build radiomic signature, and clinical characteristics and radiomic signature were combined to develop radiomic nomogram for LDCT and standard-dose CT, respectively. The performance of radiomic models and Lung-RADS was assessed by area under curve (AUC) of receiver operating characteristic curve, sensitivity, and specificity. Shape and first order features, and neighboring gray tone difference matrix features were highly reproducible between LDCT and standard-dose CT. No significant differences of AUCs were found among radiomic signature and nomogram of LDCT and standard-dose CT in both primary and validation cohort (0.915 0.919 0.898 0.909 and 0.976 0.976 0.985 0.987, respectively). These radiomic models had higher specificity than Lung-RADS (all correct &lt; 0.05), while there were no significant differences of sensitivity between Lung-RADS and radiomic models. The diagnostic performance of LDCT-based radiomic models to differentiate adenocarcinomas from benign lesions in solid pulmonary nodules were equivalent to that of standard-dose CT. The LDCT-based radiomic model with higher specificity and lower false-positive rate than Lung-RADS might help reduce overdiagnosis and overtreatment of solid pulmonary nodules in lung cancer screening.</abstract><cop>Switzerland</cop><pub>Frontiers Media S.A</pub><pmid>33604303</pmid><doi>10.3389/fonc.2020.634298</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2234-943X
ispartof Frontiers in oncology, 2021-02, Vol.10, p.634298-634298
issn 2234-943X
2234-943X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_545dc99876844ebba2ea8d8d77f819c9
source PubMed (Medline)
subjects benign lesion
low-dose computed tomography
lung adenocarcinoma
lung cancer screening
Oncology
radiomics
solid pulmonary nodule
title Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-24T21%3A24%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Radiomic%20Models%20Based%20on%20Low-Dose%20and%20Standard-Dose%20CT%20for%20Prediction%20of%20Adenocarcinomas%20and%20Benign%20Lesions%20in%20Solid%20Pulmonary%20Nodules&rft.jtitle=Frontiers%20in%20oncology&rft.au=Liu,%20Jieke&rft.date=2021-02-02&rft.volume=10&rft.spage=634298&rft.epage=634298&rft.pages=634298-634298&rft.issn=2234-943X&rft.eissn=2234-943X&rft_id=info:doi/10.3389/fonc.2020.634298&rft_dat=%3Cproquest_doaj_%3E2491943281%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c462t-1f48f393d6a43fc8513c08dafb5375e8b0ff008651c63c97be014c64ebf2db23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2491943281&rft_id=info:pmid/33604303&rfr_iscdi=true