Loading…

Implantable cardioverter defibrillator and cardiac resynchronization therapy use in New Zealand (ANZACS‐QI 33)

Background The ANZACS‐QI Cardiac Implanted Device Registry (ANZACS‐QI DEVICE) collects nationwide data on cardiac implantable electronic devices in New Zealand (NZ). We used the registry to describe contemporary NZ use of implantable cardioverter defibrillator (ICD) and cardiac resynchronization the...

Full description

Saved in:
Bibliographic Details
Published in:Journal of arrhythmia 2020-02, Vol.36 (1), p.153-163
Main Authors: Foo, Fang Shawn, Lee, Mildred, Looi, Khang‐Li, Larsen, Peter, Clare, Geoffrey C., Heaven, David, Stiles, Martin K., Voss, Jamie, Boddington, Dean, Jackson, Rod, Kerr, Andrew J., Nunn, C., Sutcliffe, G., Devlin, G., White, H., Edmond, J., Tisch, J., Riddle, S., Marshall, K., Lund, M., Williams, M., Fisher, N., Scott, T., Sutherland, K., Flynn, C., Rhodes, M., Rattray, A., Chan, R., Jiang, Y., Jenkins, M., Faatui, J., Lindesay, M., Money, J., Singh, R., Chatburn, R., Kelly, R., Salmon, J., Visser, A., Youbard, J., Brett, S., Khan, S., Metrick, R., Harris, P., Sinclair, S., Jolly, B., Cheriyan, A., Riddell, F., Finnemore, H., Orsbourn, G., Williams, C., Turner, K., Maas, K., Donald, J., Kitipa, L., Cooper, L., Fowler, M., Brown, T., Takau, S., Chang, C., McLean, F., Smith, C., Allen, R., Timmins, K., Coley, K., Jones, P., Anthony‐Pudumai, N., Day, V., Stuit, V., Simms, L., Whiteley, C., Wilson, A., Hunter, K., Tait, S., Bishop, P., Cookley, M., Cumming, T., Goodson, J., Thacker, O., Guglietta, E., Milmine, V., Cotton, J., Wilson, L., Lawson, T., White, J., Breakwell, R., Searby, K., Slipper, D., Lipski, M., Sohil, A., Todd, K., Tilsley, C., Harris, K., Clayton, A., Moloney, L., Scott, B., Wylie, D.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background The ANZACS‐QI Cardiac Implanted Device Registry (ANZACS‐QI DEVICE) collects nationwide data on cardiac implantable electronic devices in New Zealand (NZ). We used the registry to describe contemporary NZ use of implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT). Methods All ICD and CRT Pacemaker implants recorded in ANZACS‐QI DEVICE between 1 January 2014 and 31 December 2017 were analyzed. Results Of 1579 ICD implants, 1152 (73.0%) were new implants, including 49.0% for primary prevention and 51.0% for secondary prevention. In both groups, median age was 62 years and patients were predominantly male (81.4% and 79.2%, respectively). Most patients receiving a primary prevention ICD had a history of clinical heart failure (80.4%), NYHA class II‐III symptoms (77.1%) and LVEF ≤35% (96.9%). In the secondary prevention ICD cohort, 88.4% were for sustained ventricular tachycardia or survived cardiac arrest from ventricular arrhythmia. Compared to primary prevention CRT Defibrillators (n = 155), those receiving CRT Pacemakers (n = 175) were older (median age 74 vs 66 years) and more likely to be female (38.3% vs 19.4%). Of the 427 (27.0%) ICD replacements (mean duration 6.3 years), 46.6% had received appropriate device therapy while 17.8% received inappropriate therapy. The ICD implant rate was 119 per million population with regional variation in implant rates, ratio of primary prevention ICD implants, and selection of CRT modality. Conclusion In contemporary NZ practice three‐quarters of ICD implants were new implants, of which half were for primary prevention. The majority met current guideline indications. Patients receiving CRT pacemaker were older and more likely to be female. This paper utilized the ANZACS‐QI Cardiac Implanted Device Registry to describe contemporary use of implantable cardioverter defibrillator (ICD) and cardiac resynchronization therapy (CRT) in New Zealand. Three‐quarters of ICD implants were new implants, of which half were for primary prevention. Compared to primary prevention CRT Defibrillators, those receiving CRT Pacemakers were older and more likely to be female. The ICD implant rate was 119 per million population with regional variation in implant rates, ratio of primary prevention ICD implants, and selection of CRT modality.
ISSN:1880-4276
1883-2148
DOI:10.1002/joa3.12244