Loading…

Inductive voltage divider calibration with sampling method

This paper presents an automatic system developed at METAS for the calibration of inductive voltage dividers (IVD). The used method is primary for the n/10 ratio. With the described improvements, the calibration of IVDs has been made easier, faster and more reproducible than with the manual system u...

Full description

Saved in:
Bibliographic Details
Published in:EPJ Web of conferences 2014, Vol.77, p.14-1-00014-6
Main Authors: Corminboeuf, David, Overney, Frédéric
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper presents an automatic system developed at METAS for the calibration of inductive voltage dividers (IVD). The used method is primary for the n/10 ratio. With the described improvements, the calibration of IVDs has been made easier, faster and more reproducible than with the manual system used before. The uncertainties which can be reached with this new system are 28 times 10 super(-9) for the in phase and quadrature parts at a frequency of 1 kHz.
ISSN:2100-014X
2100-014X
DOI:10.1051/epjconf/20147700014