Loading…

Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors

Abstract Distal biceps tendon ruptures are uncommon injuries responsible for only 3% of all injuries to the biceps tendon. For most of these cases, unless the patient is elderly or infirm, conservative management should be avoided and the injury should be treated with a surgical procedure to reattac...

Full description

Saved in:
Bibliographic Details
Published in:Arthroscopy techniques (Amsterdam) 2018-11, Vol.7 (11), p.e1177-e1180
Main Authors: Woodall, Brittany M., D.O, Youn, Gun Min, B.A, Elena, Nicholas, M.D, Rosinski, Alexander, M.S, Chakrabarti, Moyukh, M.B.B.S, Gwosdz, James, M.D, Shin, Edward C., M.D, Pathare, Neil, M.D, McGahan, Patrick J., M.D, Chen, James L., M.D., M.P.H
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403
cites cdi_FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403
container_end_page e1180
container_issue 11
container_start_page e1177
container_title Arthroscopy techniques (Amsterdam)
container_volume 7
creator Woodall, Brittany M., D.O
Youn, Gun Min, B.A
Elena, Nicholas, M.D
Rosinski, Alexander, M.S
Chakrabarti, Moyukh, M.B.B.S
Gwosdz, James, M.D
Shin, Edward C., M.D
Pathare, Neil, M.D
McGahan, Patrick J., M.D
Chen, James L., M.D., M.P.H
description Abstract Distal biceps tendon ruptures are uncommon injuries responsible for only 3% of all injuries to the biceps tendon. For most of these cases, unless the patient is elderly or infirm, conservative management should be avoided and the injury should be treated with a surgical procedure to reattach the bicep tendon to the radial tuberosity. In this Technical Note and accompanying video, we describe an anatomic single-incision technique using 2 intramedullary soft anchors, which decreases the likelihood of complications associated with bicortical drilling and metal suspensory fixation.
doi_str_mv 10.1016/j.eats.2018.07.015
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_59142270b7ef4171aa9865fd2596d71e</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S2212628718301257</els_id><doaj_id>oai_doaj_org_article_59142270b7ef4171aa9865fd2596d71e</doaj_id><sourcerecordid>2155164700</sourcerecordid><originalsourceid>FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403</originalsourceid><addsrcrecordid>eNpVUk1v3CAQtapWTbTNH-ih4tiLXT4M2JdK2_RrpUiVuskZYTxscL3ggh0p_764m6YJHEAM7828eVMUbwmuCCbiw1CBnlNFMWkqLCtM-IvinFJCS0Eb-fLJ_ay4SGnAeTVE4lq-Ls4Y5owxIc6Lbuv1HI7OoL3zhxHKnTcuueDRT5i0iyhY9NmlWY_okzMwJXQNvl_DyzQvERK6SRmIdn6O-gj9Mo463qN9sDPaenMbYnpTvLJ6THDxcG6Km69fri-_l1c_vu0ut1el4ZTNJWjgDfBay3bdNTDNiKiFAcpF33ZUW20x6wiwjpmmtVRryWXbUGZlXWO2KXYn3j7oQU3RHXMlKmin_j6EeFA6zs6MoHhLakol7iTYmkiiddsIbnvKW9HLnGFTfDxxTUuXVRlY5Y3PSJ9HvLtVh3CnBBWU1jwTvH8giOH3AmlWR5cM5O54CEtSlHCe1Um81k1PX00MKUWwj2kIVqvXalCr12r1WmGpstcZ9O5pgY-Qf87-VwC55XcOojKj887o8RfcQxrCEn12QxGVqMJqv47LOi2kYZhQLtkfFma7bA</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2155164700</pqid></control><display><type>article</type><title>Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors</title><source>PubMed Central Free</source><source>Elsevier ScienceDirect Journals</source><creator>Woodall, Brittany M., D.O ; Youn, Gun Min, B.A ; Elena, Nicholas, M.D ; Rosinski, Alexander, M.S ; Chakrabarti, Moyukh, M.B.B.S ; Gwosdz, James, M.D ; Shin, Edward C., M.D ; Pathare, Neil, M.D ; McGahan, Patrick J., M.D ; Chen, James L., M.D., M.P.H</creator><creatorcontrib>Woodall, Brittany M., D.O ; Youn, Gun Min, B.A ; Elena, Nicholas, M.D ; Rosinski, Alexander, M.S ; Chakrabarti, Moyukh, M.B.B.S ; Gwosdz, James, M.D ; Shin, Edward C., M.D ; Pathare, Neil, M.D ; McGahan, Patrick J., M.D ; Chen, James L., M.D., M.P.H</creatorcontrib><description>Abstract Distal biceps tendon ruptures are uncommon injuries responsible for only 3% of all injuries to the biceps tendon. For most of these cases, unless the patient is elderly or infirm, conservative management should be avoided and the injury should be treated with a surgical procedure to reattach the bicep tendon to the radial tuberosity. In this Technical Note and accompanying video, we describe an anatomic single-incision technique using 2 intramedullary soft anchors, which decreases the likelihood of complications associated with bicortical drilling and metal suspensory fixation.</description><identifier>ISSN: 2212-6287</identifier><identifier>EISSN: 2212-6287</identifier><identifier>DOI: 10.1016/j.eats.2018.07.015</identifier><identifier>PMID: 30533366</identifier><language>eng</language><publisher>Netherlands: Elsevier</publisher><subject>Orthopedics ; Technical Note</subject><ispartof>Arthroscopy techniques (Amsterdam), 2018-11, Vol.7 (11), p.e1177-e1180</ispartof><rights>Arthroscopy Association of North America</rights><rights>2018 by the Arthroscopy Association of North America. Published by Elsevier. 2018 Arthroscopy Association of North America</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403</citedby><cites>FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6262245/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6262245/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30533366$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Woodall, Brittany M., D.O</creatorcontrib><creatorcontrib>Youn, Gun Min, B.A</creatorcontrib><creatorcontrib>Elena, Nicholas, M.D</creatorcontrib><creatorcontrib>Rosinski, Alexander, M.S</creatorcontrib><creatorcontrib>Chakrabarti, Moyukh, M.B.B.S</creatorcontrib><creatorcontrib>Gwosdz, James, M.D</creatorcontrib><creatorcontrib>Shin, Edward C., M.D</creatorcontrib><creatorcontrib>Pathare, Neil, M.D</creatorcontrib><creatorcontrib>McGahan, Patrick J., M.D</creatorcontrib><creatorcontrib>Chen, James L., M.D., M.P.H</creatorcontrib><title>Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors</title><title>Arthroscopy techniques (Amsterdam)</title><addtitle>Arthrosc Tech</addtitle><description>Abstract Distal biceps tendon ruptures are uncommon injuries responsible for only 3% of all injuries to the biceps tendon. For most of these cases, unless the patient is elderly or infirm, conservative management should be avoided and the injury should be treated with a surgical procedure to reattach the bicep tendon to the radial tuberosity. In this Technical Note and accompanying video, we describe an anatomic single-incision technique using 2 intramedullary soft anchors, which decreases the likelihood of complications associated with bicortical drilling and metal suspensory fixation.</description><subject>Orthopedics</subject><subject>Technical Note</subject><issn>2212-6287</issn><issn>2212-6287</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVUk1v3CAQtapWTbTNH-ih4tiLXT4M2JdK2_RrpUiVuskZYTxscL3ggh0p_764m6YJHEAM7828eVMUbwmuCCbiw1CBnlNFMWkqLCtM-IvinFJCS0Eb-fLJ_ay4SGnAeTVE4lq-Ls4Y5owxIc6Lbuv1HI7OoL3zhxHKnTcuueDRT5i0iyhY9NmlWY_okzMwJXQNvl_DyzQvERK6SRmIdn6O-gj9Mo463qN9sDPaenMbYnpTvLJ6THDxcG6Km69fri-_l1c_vu0ut1el4ZTNJWjgDfBay3bdNTDNiKiFAcpF33ZUW20x6wiwjpmmtVRryWXbUGZlXWO2KXYn3j7oQU3RHXMlKmin_j6EeFA6zs6MoHhLakol7iTYmkiiddsIbnvKW9HLnGFTfDxxTUuXVRlY5Y3PSJ9HvLtVh3CnBBWU1jwTvH8giOH3AmlWR5cM5O54CEtSlHCe1Um81k1PX00MKUWwj2kIVqvXalCr12r1WmGpstcZ9O5pgY-Qf87-VwC55XcOojKj887o8RfcQxrCEn12QxGVqMJqv47LOi2kYZhQLtkfFma7bA</recordid><startdate>20181101</startdate><enddate>20181101</enddate><creator>Woodall, Brittany M., D.O</creator><creator>Youn, Gun Min, B.A</creator><creator>Elena, Nicholas, M.D</creator><creator>Rosinski, Alexander, M.S</creator><creator>Chakrabarti, Moyukh, M.B.B.S</creator><creator>Gwosdz, James, M.D</creator><creator>Shin, Edward C., M.D</creator><creator>Pathare, Neil, M.D</creator><creator>McGahan, Patrick J., M.D</creator><creator>Chen, James L., M.D., M.P.H</creator><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>20181101</creationdate><title>Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors</title><author>Woodall, Brittany M., D.O ; Youn, Gun Min, B.A ; Elena, Nicholas, M.D ; Rosinski, Alexander, M.S ; Chakrabarti, Moyukh, M.B.B.S ; Gwosdz, James, M.D ; Shin, Edward C., M.D ; Pathare, Neil, M.D ; McGahan, Patrick J., M.D ; Chen, James L., M.D., M.P.H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Orthopedics</topic><topic>Technical Note</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Woodall, Brittany M., D.O</creatorcontrib><creatorcontrib>Youn, Gun Min, B.A</creatorcontrib><creatorcontrib>Elena, Nicholas, M.D</creatorcontrib><creatorcontrib>Rosinski, Alexander, M.S</creatorcontrib><creatorcontrib>Chakrabarti, Moyukh, M.B.B.S</creatorcontrib><creatorcontrib>Gwosdz, James, M.D</creatorcontrib><creatorcontrib>Shin, Edward C., M.D</creatorcontrib><creatorcontrib>Pathare, Neil, M.D</creatorcontrib><creatorcontrib>McGahan, Patrick J., M.D</creatorcontrib><creatorcontrib>Chen, James L., M.D., M.P.H</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Arthroscopy techniques (Amsterdam)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Woodall, Brittany M., D.O</au><au>Youn, Gun Min, B.A</au><au>Elena, Nicholas, M.D</au><au>Rosinski, Alexander, M.S</au><au>Chakrabarti, Moyukh, M.B.B.S</au><au>Gwosdz, James, M.D</au><au>Shin, Edward C., M.D</au><au>Pathare, Neil, M.D</au><au>McGahan, Patrick J., M.D</au><au>Chen, James L., M.D., M.P.H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors</atitle><jtitle>Arthroscopy techniques (Amsterdam)</jtitle><addtitle>Arthrosc Tech</addtitle><date>2018-11-01</date><risdate>2018</risdate><volume>7</volume><issue>11</issue><spage>e1177</spage><epage>e1180</epage><pages>e1177-e1180</pages><issn>2212-6287</issn><eissn>2212-6287</eissn><abstract>Abstract Distal biceps tendon ruptures are uncommon injuries responsible for only 3% of all injuries to the biceps tendon. For most of these cases, unless the patient is elderly or infirm, conservative management should be avoided and the injury should be treated with a surgical procedure to reattach the bicep tendon to the radial tuberosity. In this Technical Note and accompanying video, we describe an anatomic single-incision technique using 2 intramedullary soft anchors, which decreases the likelihood of complications associated with bicortical drilling and metal suspensory fixation.</abstract><cop>Netherlands</cop><pub>Elsevier</pub><pmid>30533366</pmid><doi>10.1016/j.eats.2018.07.015</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2212-6287
ispartof Arthroscopy techniques (Amsterdam), 2018-11, Vol.7 (11), p.e1177-e1180
issn 2212-6287
2212-6287
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_59142270b7ef4171aa9865fd2596d71e
source PubMed Central Free; Elsevier ScienceDirect Journals
subjects Orthopedics
Technical Note
title Anatomic Single-Incision Repair of Distal Biceps Tendon Ruptures Using Intramedullary Soft Anchors
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T00%3A58%3A48IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Anatomic%20Single-Incision%20Repair%20of%20Distal%20Biceps%20Tendon%20Ruptures%20Using%20Intramedullary%20Soft%20Anchors&rft.jtitle=Arthroscopy%20techniques%20(Amsterdam)&rft.au=Woodall,%20Brittany%20M.,%20D.O&rft.date=2018-11-01&rft.volume=7&rft.issue=11&rft.spage=e1177&rft.epage=e1180&rft.pages=e1177-e1180&rft.issn=2212-6287&rft.eissn=2212-6287&rft_id=info:doi/10.1016/j.eats.2018.07.015&rft_dat=%3Cproquest_doaj_%3E2155164700%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c523t-eae58e54a7979794e3a31646ce256d9b2afaf03b1e3b3c89f2aa7579823f74403%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2155164700&rft_id=info:pmid/30533366&rfr_iscdi=true