Loading…
Experimental performance studies of small wall room air conditioner for R410A retrofitted with R290
An original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively. In this study, the compressor R410A wall room air conditioner compressor was replaced with an...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference Proceeding |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | An original R410A wall room air conditioner was retrofitted with R290 for performance experiments. The R410A wall room air conditioner has a COP and a refrigerating capacity 6.0597and 1929.3 W respectively. In this study, the compressor R410A wall room air conditioner compressor was replaced with an R22 which is compatible. Mass R290 charged into the wall room air conditioner was 33.88%, 38.12% and 42.35%. Refrigerating capacity obtained was 1837 W, 1848.2 W and 2008.4W, while the COP was 5.2014, 5.0294, and 5.3275. The results obtained the R410A wall room air conditioner performance better than if the air conditioning machine retrofitted with R290. |
---|---|
ISSN: | 2261-236X 2274-7214 2261-236X |
DOI: | 10.1051/matecconf/201815901051 |