Loading…

Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study

Objectives: Titanium dental implants can last for more than two decades in the oral environment. Corrosion of the implant surface can release metallic particles or ions into surrounding tissue. The metallic constituents like titanium in human blood serum have not been fully studied. The study compar...

Full description

Saved in:
Bibliographic Details
Published in:Dentistry 3000 2024-05, Vol.12 (1)
Main Authors: S, Mahantesha, Shetty, Vibha, K, Kranti, Subbaiah, Shobha, C, Greeshma, Alva, Babashankar, Sharma, Manish
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 1
container_start_page
container_title Dentistry 3000
container_volume 12
creator S, Mahantesha
Shetty, Vibha
K, Kranti
Subbaiah, Shobha
C, Greeshma
Alva, Babashankar
Sharma, Manish
description Objectives: Titanium dental implants can last for more than two decades in the oral environment. Corrosion of the implant surface can release metallic particles or ions into surrounding tissue. The metallic constituents like titanium in human blood serum have not been fully studied. The study compares titanium serum levels before and after dental implant placement and compares levels in patients with healthy implants and those with per-implantitis. Methods: The study comprised 2groups of Group 1 patient observing implant surgery and group 2 patients with diagnosed peri-implantitis. Each group comprised of 60 patients. Serum titanium level was measured from blood obtained from Group 1 at three different intervals (one month prior to implant surgery, 4th and 8th month after successful loading) and from Group 2 during the course of peri-implantitis by inductively coupled plasma–mass spectroscopy. The statistical analysis was done for the obtained data. Results: Analysis showed a raised level of serum titanium at 4th month of post implant placement (2.39 mg/dl) and in patient with peri-implantitis(2.94 mg/dl) and both levels are significantly differ (ANOVA test) from pre-surgical estimation of serum titanium level (1.79 mg/dl). Conclusions: Understanding the correlation between titanium corrosion and peri-implantitis is vital for enhancing the long-term success and safety of dental implants. Additional research is required to investigate these links and potential strategies to protect the well-being of implant patients.
doi_str_mv 10.5195/d3000.2024.594
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_6232750e794d4dcf8cdd5fe58b58d010</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_6232750e794d4dcf8cdd5fe58b58d010</doaj_id><sourcerecordid>oai_doaj_org_article_6232750e794d4dcf8cdd5fe58b58d010</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2154-2da49f6e370ae6110accd0179f5e6f4f35bc583dedf460e60cdca3fb8f9853d3</originalsourceid><addsrcrecordid>eNpNUctuwjAQjKpWKqJce_YPhNpx7CRHhPpAQuqFu7XY62KUl2xDxbf0Z2ugrXrax4xmdjVZ9sjoXLBGPBlOKZ0XtCjnoilvsknBZJXXsqpu__X32SyEfWKyQlSyaSbZ13LoRvAQ3REJ9NCeggtksCSgP3Qkugi9S02LR2yJ68mYqNhH8unijuwQ2rg7EZM2kOBubCFh0JtfXrgSR_Qu_4FddCEnC6L9EELy0dENyZiMaR7PU7okxIM5PWR3FtqAs586zTYvz5vlW75-f10tF-tcF0yUeWGgbKxEXlFAyRgFrQ1lVWMFSltaLrZa1NygsaWkKKk2Grjd1rapBTd8mq2usmaAvRq968Cf1ABOXRaD_1Dgo9MtKlnwohIUq6Y0pdG21sYIi6LeijpZ0qQ1v2pdnvNo__QYVeeg1CUodQ5KpaD4N-4xisE</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study</title><source>Publicly Available Content (ProQuest)</source><creator>S, Mahantesha ; Shetty, Vibha ; K, Kranti ; Subbaiah, Shobha ; C, Greeshma ; Alva, Babashankar ; Sharma, Manish</creator><creatorcontrib>S, Mahantesha ; Shetty, Vibha ; K, Kranti ; Subbaiah, Shobha ; C, Greeshma ; Alva, Babashankar ; Sharma, Manish</creatorcontrib><description>Objectives: Titanium dental implants can last for more than two decades in the oral environment. Corrosion of the implant surface can release metallic particles or ions into surrounding tissue. The metallic constituents like titanium in human blood serum have not been fully studied. The study compares titanium serum levels before and after dental implant placement and compares levels in patients with healthy implants and those with per-implantitis. Methods: The study comprised 2groups of Group 1 patient observing implant surgery and group 2 patients with diagnosed peri-implantitis. Each group comprised of 60 patients. Serum titanium level was measured from blood obtained from Group 1 at three different intervals (one month prior to implant surgery, 4th and 8th month after successful loading) and from Group 2 during the course of peri-implantitis by inductively coupled plasma–mass spectroscopy. The statistical analysis was done for the obtained data. Results: Analysis showed a raised level of serum titanium at 4th month of post implant placement (2.39 mg/dl) and in patient with peri-implantitis(2.94 mg/dl) and both levels are significantly differ (ANOVA test) from pre-surgical estimation of serum titanium level (1.79 mg/dl). Conclusions: Understanding the correlation between titanium corrosion and peri-implantitis is vital for enhancing the long-term success and safety of dental implants. Additional research is required to investigate these links and potential strategies to protect the well-being of implant patients.</description><identifier>ISSN: 2167-8677</identifier><identifier>EISSN: 2167-8677</identifier><identifier>DOI: 10.5195/d3000.2024.594</identifier><language>eng</language><publisher>University Library System, University of Pittsburgh</publisher><subject>Dental implants ; Inductively coupled plasma–mass spectroscopy ; Peri-implantitis ; Serum titanium ; Titanium alloys</subject><ispartof>Dentistry 3000, 2024-05, Vol.12 (1)</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>S, Mahantesha</creatorcontrib><creatorcontrib>Shetty, Vibha</creatorcontrib><creatorcontrib>K, Kranti</creatorcontrib><creatorcontrib>Subbaiah, Shobha</creatorcontrib><creatorcontrib>C, Greeshma</creatorcontrib><creatorcontrib>Alva, Babashankar</creatorcontrib><creatorcontrib>Sharma, Manish</creatorcontrib><title>Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study</title><title>Dentistry 3000</title><description>Objectives: Titanium dental implants can last for more than two decades in the oral environment. Corrosion of the implant surface can release metallic particles or ions into surrounding tissue. The metallic constituents like titanium in human blood serum have not been fully studied. The study compares titanium serum levels before and after dental implant placement and compares levels in patients with healthy implants and those with per-implantitis. Methods: The study comprised 2groups of Group 1 patient observing implant surgery and group 2 patients with diagnosed peri-implantitis. Each group comprised of 60 patients. Serum titanium level was measured from blood obtained from Group 1 at three different intervals (one month prior to implant surgery, 4th and 8th month after successful loading) and from Group 2 during the course of peri-implantitis by inductively coupled plasma–mass spectroscopy. The statistical analysis was done for the obtained data. Results: Analysis showed a raised level of serum titanium at 4th month of post implant placement (2.39 mg/dl) and in patient with peri-implantitis(2.94 mg/dl) and both levels are significantly differ (ANOVA test) from pre-surgical estimation of serum titanium level (1.79 mg/dl). Conclusions: Understanding the correlation between titanium corrosion and peri-implantitis is vital for enhancing the long-term success and safety of dental implants. Additional research is required to investigate these links and potential strategies to protect the well-being of implant patients.</description><subject>Dental implants</subject><subject>Inductively coupled plasma–mass spectroscopy</subject><subject>Peri-implantitis</subject><subject>Serum titanium</subject><subject>Titanium alloys</subject><issn>2167-8677</issn><issn>2167-8677</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNUctuwjAQjKpWKqJce_YPhNpx7CRHhPpAQuqFu7XY62KUl2xDxbf0Z2ugrXrax4xmdjVZ9sjoXLBGPBlOKZ0XtCjnoilvsknBZJXXsqpu__X32SyEfWKyQlSyaSbZ13LoRvAQ3REJ9NCeggtksCSgP3Qkugi9S02LR2yJ68mYqNhH8unijuwQ2rg7EZM2kOBubCFh0JtfXrgSR_Qu_4FddCEnC6L9EELy0dENyZiMaR7PU7okxIM5PWR3FtqAs586zTYvz5vlW75-f10tF-tcF0yUeWGgbKxEXlFAyRgFrQ1lVWMFSltaLrZa1NygsaWkKKk2Grjd1rapBTd8mq2usmaAvRq968Cf1ABOXRaD_1Dgo9MtKlnwohIUq6Y0pdG21sYIi6LeijpZ0qQ1v2pdnvNo__QYVeeg1CUodQ5KpaD4N-4xisE</recordid><startdate>20240506</startdate><enddate>20240506</enddate><creator>S, Mahantesha</creator><creator>Shetty, Vibha</creator><creator>K, Kranti</creator><creator>Subbaiah, Shobha</creator><creator>C, Greeshma</creator><creator>Alva, Babashankar</creator><creator>Sharma, Manish</creator><general>University Library System, University of Pittsburgh</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>20240506</creationdate><title>Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study</title><author>S, Mahantesha ; Shetty, Vibha ; K, Kranti ; Subbaiah, Shobha ; C, Greeshma ; Alva, Babashankar ; Sharma, Manish</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2154-2da49f6e370ae6110accd0179f5e6f4f35bc583dedf460e60cdca3fb8f9853d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Dental implants</topic><topic>Inductively coupled plasma–mass spectroscopy</topic><topic>Peri-implantitis</topic><topic>Serum titanium</topic><topic>Titanium alloys</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>S, Mahantesha</creatorcontrib><creatorcontrib>Shetty, Vibha</creatorcontrib><creatorcontrib>K, Kranti</creatorcontrib><creatorcontrib>Subbaiah, Shobha</creatorcontrib><creatorcontrib>C, Greeshma</creatorcontrib><creatorcontrib>Alva, Babashankar</creatorcontrib><creatorcontrib>Sharma, Manish</creatorcontrib><collection>CrossRef</collection><collection>Directory of Open Access Journals</collection><jtitle>Dentistry 3000</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>S, Mahantesha</au><au>Shetty, Vibha</au><au>K, Kranti</au><au>Subbaiah, Shobha</au><au>C, Greeshma</au><au>Alva, Babashankar</au><au>Sharma, Manish</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study</atitle><jtitle>Dentistry 3000</jtitle><date>2024-05-06</date><risdate>2024</risdate><volume>12</volume><issue>1</issue><issn>2167-8677</issn><eissn>2167-8677</eissn><abstract>Objectives: Titanium dental implants can last for more than two decades in the oral environment. Corrosion of the implant surface can release metallic particles or ions into surrounding tissue. The metallic constituents like titanium in human blood serum have not been fully studied. The study compares titanium serum levels before and after dental implant placement and compares levels in patients with healthy implants and those with per-implantitis. Methods: The study comprised 2groups of Group 1 patient observing implant surgery and group 2 patients with diagnosed peri-implantitis. Each group comprised of 60 patients. Serum titanium level was measured from blood obtained from Group 1 at three different intervals (one month prior to implant surgery, 4th and 8th month after successful loading) and from Group 2 during the course of peri-implantitis by inductively coupled plasma–mass spectroscopy. The statistical analysis was done for the obtained data. Results: Analysis showed a raised level of serum titanium at 4th month of post implant placement (2.39 mg/dl) and in patient with peri-implantitis(2.94 mg/dl) and both levels are significantly differ (ANOVA test) from pre-surgical estimation of serum titanium level (1.79 mg/dl). Conclusions: Understanding the correlation between titanium corrosion and peri-implantitis is vital for enhancing the long-term success and safety of dental implants. Additional research is required to investigate these links and potential strategies to protect the well-being of implant patients.</abstract><pub>University Library System, University of Pittsburgh</pub><doi>10.5195/d3000.2024.594</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2167-8677
ispartof Dentistry 3000, 2024-05, Vol.12 (1)
issn 2167-8677
2167-8677
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_6232750e794d4dcf8cdd5fe58b58d010
source Publicly Available Content (ProQuest)
subjects Dental implants
Inductively coupled plasma–mass spectroscopy
Peri-implantitis
Serum titanium
Titanium alloys
title Comparative analysis of serum titanium level in patient with healthy dental implant and patients with peri-implantitis- A cross sectional prospective study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T19%3A09%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20analysis%20of%20serum%20titanium%20level%20in%20patient%20with%20healthy%20dental%20implant%20and%20patients%20with%20peri-implantitis-%20A%20cross%20sectional%20prospective%20study&rft.jtitle=Dentistry%203000&rft.au=S,%20Mahantesha&rft.date=2024-05-06&rft.volume=12&rft.issue=1&rft.issn=2167-8677&rft.eissn=2167-8677&rft_id=info:doi/10.5195/d3000.2024.594&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_6232750e794d4dcf8cdd5fe58b58d010%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2154-2da49f6e370ae6110accd0179f5e6f4f35bc583dedf460e60cdca3fb8f9853d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true