ProtekDuo Cannula for Pre-, Intra-, and Postoperative Lung Transplantation Management

We present a 61-year-old patient with pulmonary hypertension, acute respiratory failure, and acute severe right ventricular (RV) dysfunction. Preoperatively, a ProtekDuo® was inserted for extracorporeal membrane oxygenation (ECMO) and RV protection with venopulmonary (VP) ECMO in (dl) V-P ECMO confi...

Full description

Saved in:
Bibliographic Details
Published in:Annals of cardiac anaesthesia 2024-10, Vol.27 (4), p.375-378
Main Authors: Ricks, William A, Rackauskas, Mindaugas, Weir, William B, Emtiazjoo, Amir M, Saha, Biplab K, Gries, Cynthia J, Maybauer, Marc O
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present a 61-year-old patient with pulmonary hypertension, acute respiratory failure, and acute severe right ventricular (RV) dysfunction. Preoperatively, a ProtekDuo® was inserted for extracorporeal membrane oxygenation (ECMO) and RV protection with venopulmonary (VP) ECMO in (dl) V-P ECMO configuration. Intraoperatively, it provided venous drainage for venoarterial (VA) ECMO in (dl) VP-/AO configuration for bilateral orthotopic lung transplantation (BOLT). Postoperatively, the patient remained on (dl) V-P ECMO for RV support and was decannulated with mild RV dysfunction after 5 days. This is the first description of the ProtekDuo® used in (dl) V-P to (dl) VP-/AO to (dl) V-P configuration for the entire perioperative period of BOLT.