Loading…

Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System

The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although...

Full description

Saved in:
Bibliographic Details
Published in:Energies (Basel) 2021-04, Vol.14 (8), p.2273
Main Authors: Park, Seung-Hoon, Jang, Yong-Sung, Kim, Eui-Jong
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733
cites cdi_FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733
container_end_page
container_issue 8
container_start_page 2273
container_title Energies (Basel)
container_volume 14
creator Park, Seung-Hoon
Jang, Yong-Sung
Kim, Eui-Jong
description The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.
doi_str_mv 10.3390/en14082273
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_66855b7173d048b5be778c687d4aee06</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_66855b7173d048b5be778c687d4aee06</doaj_id><sourcerecordid>oai_doaj_org_article_66855b7173d048b5be778c687d4aee06</sourcerecordid><originalsourceid>FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733</originalsourceid><addsrcrecordid>eNpNkNtKAzEQhoMoWGpvfIJcC6vJzm4Ol9JWWyhY0F6H7Ga2pOyhZFOlPr1bK-rczPH_GH5Cbjm7B9DsAVueMZWmEi7IiGstEs4kXP6rr8mk73dsCAAOACNiZtj7bUtt6-gaQ9WFxrYl0vm7rQ82-q6lXUUtXaCNdH1o9vT12Eds6Cb62n_6djssB-GgwjbSGX7YiOE0Pt_dkKvK1j1OfvKYbJ7mb9NFsnp5Xk4fV0k5vBETAKcyzYXmldAKIQWXl67IT70DVuZ54VJhK5k5xQoFXGWp0kKnXBeZlgBjsjxzXWd3Zh98Y8PRdNab70EXtsaG6MsajRBqwEkuwbFMFXmBUqpSKOkyi8jEwLo7s8rQ9X3A6pfHmTk5bf6chi9esG7s</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><creator>Park, Seung-Hoon ; Jang, Yong-Sung ; Kim, Eui-Jong</creator><creatorcontrib>Park, Seung-Hoon ; Jang, Yong-Sung ; Kim, Eui-Jong</creatorcontrib><description>The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.</description><identifier>ISSN: 1996-1073</identifier><identifier>EISSN: 1996-1073</identifier><identifier>DOI: 10.3390/en14082273</identifier><language>eng</language><publisher>MDPI AG</publisher><subject>building energy ; groundwater ; heat pump system ; permanent dewatering ; unused energy source</subject><ispartof>Energies (Basel), 2021-04, Vol.14 (8), p.2273</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733</citedby><cites>FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733</cites><orcidid>0000-0003-0647-295X ; 0000-0002-2296-4519</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Park, Seung-Hoon</creatorcontrib><creatorcontrib>Jang, Yong-Sung</creatorcontrib><creatorcontrib>Kim, Eui-Jong</creatorcontrib><title>Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System</title><title>Energies (Basel)</title><description>The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.</description><subject>building energy</subject><subject>groundwater</subject><subject>heat pump system</subject><subject>permanent dewatering</subject><subject>unused energy source</subject><issn>1996-1073</issn><issn>1996-1073</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkNtKAzEQhoMoWGpvfIJcC6vJzm4Ol9JWWyhY0F6H7Ga2pOyhZFOlPr1bK-rczPH_GH5Cbjm7B9DsAVueMZWmEi7IiGstEs4kXP6rr8mk73dsCAAOACNiZtj7bUtt6-gaQ9WFxrYl0vm7rQ82-q6lXUUtXaCNdH1o9vT12Eds6Cb62n_6djssB-GgwjbSGX7YiOE0Pt_dkKvK1j1OfvKYbJ7mb9NFsnp5Xk4fV0k5vBETAKcyzYXmldAKIQWXl67IT70DVuZ54VJhK5k5xQoFXGWp0kKnXBeZlgBjsjxzXWd3Zh98Y8PRdNab70EXtsaG6MsajRBqwEkuwbFMFXmBUqpSKOkyi8jEwLo7s8rQ9X3A6pfHmTk5bf6chi9esG7s</recordid><startdate>20210401</startdate><enddate>20210401</enddate><creator>Park, Seung-Hoon</creator><creator>Jang, Yong-Sung</creator><creator>Kim, Eui-Jong</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-0647-295X</orcidid><orcidid>https://orcid.org/0000-0002-2296-4519</orcidid></search><sort><creationdate>20210401</creationdate><title>Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System</title><author>Park, Seung-Hoon ; Jang, Yong-Sung ; Kim, Eui-Jong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>building energy</topic><topic>groundwater</topic><topic>heat pump system</topic><topic>permanent dewatering</topic><topic>unused energy source</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Park, Seung-Hoon</creatorcontrib><creatorcontrib>Jang, Yong-Sung</creatorcontrib><creatorcontrib>Kim, Eui-Jong</creatorcontrib><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Energies (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Park, Seung-Hoon</au><au>Jang, Yong-Sung</au><au>Kim, Eui-Jong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System</atitle><jtitle>Energies (Basel)</jtitle><date>2021-04-01</date><risdate>2021</risdate><volume>14</volume><issue>8</issue><spage>2273</spage><pages>2273-</pages><issn>1996-1073</issn><eissn>1996-1073</eissn><abstract>The earth provides a vast resource of groundwater from aquifers a few meters beneath the surface. Thus, buildings that use underground space must be equipped with dewatering wells to drain the permeated groundwater to the sewage pipelines to ensure the structural stability of the building. Although the inflowing groundwater temperatures and flow rates are stable enough for groundwater to be used as an energy source, 79% of the permeated groundwater is discarded through the sewers, generating significant sewerage expenses. This study introduced a novel heat exchanger module to utilize the permeated groundwater as an unused energy source using heat pumps, and the performance of the system was evaluated by TRNSYS simulations. First, the sizing of the unit heat exchanger module was proposed according to the mean inflow rate of the permeated groundwater. Second, the heat pump system was configured using multiple modules in the source-side loop. Finally, the performance of the proposed heat pump system was compared with that of a conventional air source heat pump using realistic load and temperature profiles. This preliminary study demonstrated interesting performance results, with a coefficient of performance for heating that was higher than that of a conventional heat pump system by 0.79. The results show the potential utilization of the systems for a construction project requiring large-scale underground spaces, where abundant groundwater is available.</abstract><pub>MDPI AG</pub><doi>10.3390/en14082273</doi><orcidid>https://orcid.org/0000-0003-0647-295X</orcidid><orcidid>https://orcid.org/0000-0002-2296-4519</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1996-1073
ispartof Energies (Basel), 2021-04, Vol.14 (8), p.2273
issn 1996-1073
1996-1073
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_66855b7173d048b5be778c687d4aee06
source Publicly Available Content Database (Proquest) (PQ_SDU_P3)
subjects building energy
groundwater
heat pump system
permanent dewatering
unused energy source
title Design and Performance Evaluation of a Heat Pump System Utilizing a Permanent Dewatering System
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T11%3A00%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20Performance%20Evaluation%20of%20a%20Heat%20Pump%20System%20Utilizing%20a%20Permanent%20Dewatering%20System&rft.jtitle=Energies%20(Basel)&rft.au=Park,%20Seung-Hoon&rft.date=2021-04-01&rft.volume=14&rft.issue=8&rft.spage=2273&rft.pages=2273-&rft.issn=1996-1073&rft.eissn=1996-1073&rft_id=info:doi/10.3390/en14082273&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_66855b7173d048b5be778c687d4aee06%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c333t-33d8491691f698e323d5cdb591f6d30c55bd26af74d80b8318428969219b49733%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true