Loading…

Field sensitivity and specificity of the SD BIOLINE onchocerciasis IgG4 Rapid Diagnostic Test in children <10 years old from endemic areas in Burkina Faso

Skin biopsies (Skin snips) have historically been the gold standard for the diagnosis of onchocerciasis. However, in low prevalence areas and in areas with successful ivermectin mass drug administration (MDA) programs, skin snips are not sensitive enough to decide when to stop MDA; thus, serological...

Full description

Saved in:
Bibliographic Details
Published in:Parasite epidemiology and control 2024-05, Vol.25, p.e00352-e00352, Article e00352
Main Authors: Nikièma, Achille Sindimbasba, Koala, Lassane, Unnasch, Thomas R., Diendéré, Jeoffray, Compaoré, Justin, Ouédraogo, Mathias W., Kafando, Claude Montant, Bakajika, Didier, Bougouma, Clarisse, Faye, Babacar, Traoré, Soungalo, Dabiré, Roch Kounbobr
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Skin biopsies (Skin snips) have historically been the gold standard for the diagnosis of onchocerciasis. However, in low prevalence areas and in areas with successful ivermectin mass drug administration (MDA) programs, skin snips are not sensitive enough to decide when to stop MDA; thus, serological diagnostic tools have been recommended for this purpose. This study assessed the sensitivity and specificity of the Ov16 Rapid Diagnostic Test (SD BIOLINE Onchocerciasis RDT) compared to skin snip in endemic areas undergoing ivermectin mass distribution using Community Directed Treatment with Ivermectin (CDTI) strategy. A cross-sectional study was conducted between September and November 2016 in five endemic villages in the Cascades region in Burkina Faso. Children aged 2 to 9-years were examined during the impact epidemiological survey using both the skin snip and Ov16 Rapid Diagnostic Test. The Ov16 Rapid Diagnostic Test sensitivity and specificity were determined with reference to the skin biopsy. Skin snip positivity was 1.25% in this population, while seroprevalence was 6.5%. When compared to the skin snip as the gold standard, the sensitivity of the Ov16 Rapid Diagnostic Test was 60% and the specificity 94%. When the Ov16 Rapid Diagnostic Test was considered as the gold standard, the skin snip exhibited a sensitivity of 11.5% and a specificity of 99.5%. These results are similar to other studies comparing the performance of the Ov16 ELISA to skin snips, suggesting that the Ov16 RDT may be a useful tool for ivermectin STOP MDA and post transmission surveys, assuming that the prevalence of infection is low or close to zero, and the Ov16 RDT detected also pre patent infections.
ISSN:2405-6731
2405-6731
DOI:10.1016/j.parepi.2024.e00352