Experimental study on startup characteristics of instant heat pump water heater with non-azeotropic natural blend

The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct-heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient p...

Full description

Saved in:
Bibliographic Details
Published in:Case studies in thermal engineering 2024-08, Vol.60, p.104675, Article 104675
Main Authors: Ju, Fujun, Hou, Qianlei, Fan, Xiaowei, Wu, Jiafeng, Zheng, Huifan, Liu, Qinglei, Hou, Lihao, Liu, Wenbo
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct-heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient performance parameters. Both warm start and lower OTHS helps to quickly obtain hot water at the target temperature, mainly because the system startup time in the warm start was 16.73 % shorter than that in the cold start and the system gained the shortest startup time (1015 s) in low temperature condition. The transient heat sink outlet temperature had a rapid temperature rise section and a slow temperature rise section (STRS), and the STRS consumed 56.58 %–66.67 % of the system starting time, so the improvement of STRS is the key to realize the fast startup. The effects of startup mode on the trends of transient performance parameters were memorably different, but the OTHS had no apparent effect on their trends. The transient refrigerant pressures and transient refrigerant temperatures had the fluctuations. The transient suction pressures had the minimum values (0.3925–0.5575 MPa), and both cold start mode and higher OTHS resulted in a decrease in the minimum value. •The startup performances of the DHPWH system with zeotropic natural mixture were studied experimentally.•Transient refrigerant pressures and refrigerant temperatures and transient heat sink outlet temperature were measured.•The effects of starting mode and OTHS on the startup time and change trends of transient parameters were discussed.•The improvement of slow temperature rise section is the key to achieve the fast startup of the DHPWH system.
ISSN:2214-157X
2214-157X
DOI:10.1016/j.csite.2024.104675