HemoCue analyzers are standard point-of-care devices for measuring blood hemoglobin concentration ([Hb]). The utility of these photometers has been demonstrated for all vertebrate lineages including birds, yet because most vertebrates except mammals possess nucleated red-blood cells, their [Hb] read...

Full description

Saved in:
Bibliographic Details
Published in:Journal of field ornithology 2024-09, Vol.95 (3), p.5, Article art5
Main Authors: McCracken, Kevin, Johnston, Haley, McCracken, Katherine, Olson, Riley, Otero Soberon, Jose Antonio, Turpo Aroquipa, Renzo Hernan, Alza, Luis
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 3
container_start_page 5
container_title Journal of field ornithology
container_volume 95
creator McCracken, Kevin
Johnston, Haley
McCracken, Katherine
Olson, Riley
Otero Soberon, Jose Antonio
Turpo Aroquipa, Renzo Hernan
Alza, Luis
description HemoCue analyzers are standard point-of-care devices for measuring blood hemoglobin concentration ([Hb]). The utility of these photometers has been demonstrated for all vertebrate lineages including birds, yet because most vertebrates except mammals possess nucleated red-blood cells, their [Hb] readings are inflated upward in these taxa and require a correction factor relative to the reference calibration. We field tested the newest of these analyzers, Hb801, against its predecessor, the Hb201+. Because of differences in the photometry methods, these two analyzers were not found to be equivalent for taxa with nucleated red-blood cells, such as birds. Whereas a correction factor of 1.0–1.4 g/dL is required for the Hb201+, it may be that no correction factor is required for the Hb801. Further study of the Hb801 relative to a gold-standard reference in non-mammalian lineages is warranted.
doi_str_mv 10.5751/JFO-00493-950305
format article
fullrecord <record><control><sourceid>doaj_cross</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_6ab8c2fccc2e41c295eedf1218f6a1a8</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_6ab8c2fccc2e41c295eedf1218f6a1a8</doaj_id><sourcerecordid>oai_doaj_org_article_6ab8c2fccc2e41c295eedf1218f6a1a8</sourcerecordid><originalsourceid>FETCH-LOGICAL-c234t-44ae707492ae16ae0014a59d609d505e4ddab0466fbada135fd85e7703ecbab23</originalsourceid><addsrcrecordid>eNpNkU9rGzEQxZfSQt009xx1L9tIWmn_HIupGxeDL8lZjKRRrLBaBUmm-KPk20axQ-jpPR4zjxl-TXPD6E85SHb7d7NvKRVT106SdlR-alZMyqGdeN99_s9_bb7l_EQp6znjq-ZlHcMzJNB-9uVEoiMHDPFxjtovxMTF4FISFB8XEhDyMWGoSSYuxUDKAcldHV8fq2pO2Q8Ci612pIzUfe2TzecISIAQYCb_fDmckzcTj4UsRzMjFLQkoW31HKMlBuc5f2--OJgzXr_rVfOw-X2_vmt3-z_b9a9da3gnSisE4EAHMXFA1gPWzwTIyfZ0spJKFNaCpqLvnQYLrJPOjhKHgXZoNGjeXTXbS6-N8KSekw-QTiqCV-cgpkcFqfh6pepBj4Y7YwxHwQyfJKJ1jLPR9cBgrF300mVSzDmh--hjVL1hUhWTOmNSF0zdK5mKh-s</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Comparability of hemoglobin concentration measurements from the HemoCue Hb201+ and Hb801 in birds and a mammal with and without nucleated red-blood cells</title><source>EZB Electronic Journals Library</source><creator>McCracken, Kevin ; Johnston, Haley ; McCracken, Katherine ; Olson, Riley ; Otero Soberon, Jose Antonio ; Turpo Aroquipa, Renzo Hernan ; Alza, Luis</creator><creatorcontrib>McCracken, Kevin ; Johnston, Haley ; McCracken, Katherine ; Olson, Riley ; Otero Soberon, Jose Antonio ; Turpo Aroquipa, Renzo Hernan ; Alza, Luis</creatorcontrib><description>HemoCue analyzers are standard point-of-care devices for measuring blood hemoglobin concentration ([Hb]). The utility of these photometers has been demonstrated for all vertebrate lineages including birds, yet because most vertebrates except mammals possess nucleated red-blood cells, their [Hb] readings are inflated upward in these taxa and require a correction factor relative to the reference calibration. We field tested the newest of these analyzers, Hb801, against its predecessor, the Hb201+. Because of differences in the photometry methods, these two analyzers were not found to be equivalent for taxa with nucleated red-blood cells, such as birds. Whereas a correction factor of 1.0–1.4 g/dL is required for the Hb201+, it may be that no correction factor is required for the Hb801. Further study of the Hb801 relative to a gold-standard reference in non-mammalian lineages is warranted.</description><identifier>ISSN: 1557-9263</identifier><identifier>EISSN: 1557-9263</identifier><identifier>DOI: 10.5751/JFO-00493-950305</identifier><language>eng</language><publisher>Resilience Alliance</publisher><subject>avian hematology ; hemocue ; hemoglobin concentration</subject><ispartof>Journal of field ornithology, 2024-09, Vol.95 (3), p.5, Article art5</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>McCracken, Kevin</creatorcontrib><creatorcontrib>Johnston, Haley</creatorcontrib><creatorcontrib>McCracken, Katherine</creatorcontrib><creatorcontrib>Olson, Riley</creatorcontrib><creatorcontrib>Otero Soberon, Jose Antonio</creatorcontrib><creatorcontrib>Turpo Aroquipa, Renzo Hernan</creatorcontrib><creatorcontrib>Alza, Luis</creatorcontrib><title>Comparability of hemoglobin concentration measurements from the HemoCue Hb201+ and Hb801 in birds and a mammal with and without nucleated red-blood cells</title><title>Journal of field ornithology</title><description>HemoCue analyzers are standard point-of-care devices for measuring blood hemoglobin concentration ([Hb]). The utility of these photometers has been demonstrated for all vertebrate lineages including birds, yet because most vertebrates except mammals possess nucleated red-blood cells, their [Hb] readings are inflated upward in these taxa and require a correction factor relative to the reference calibration. We field tested the newest of these analyzers, Hb801, against its predecessor, the Hb201+. Because of differences in the photometry methods, these two analyzers were not found to be equivalent for taxa with nucleated red-blood cells, such as birds. Whereas a correction factor of 1.0–1.4 g/dL is required for the Hb201+, it may be that no correction factor is required for the Hb801. Further study of the Hb801 relative to a gold-standard reference in non-mammalian lineages is warranted.</description><subject>avian hematology</subject><subject>hemocue</subject><subject>hemoglobin concentration</subject><issn>1557-9263</issn><issn>1557-9263</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkU9rGzEQxZfSQt009xx1L9tIWmn_HIupGxeDL8lZjKRRrLBaBUmm-KPk20axQ-jpPR4zjxl-TXPD6E85SHb7d7NvKRVT106SdlR-alZMyqGdeN99_s9_bb7l_EQp6znjq-ZlHcMzJNB-9uVEoiMHDPFxjtovxMTF4FISFB8XEhDyMWGoSSYuxUDKAcldHV8fq2pO2Q8Ci612pIzUfe2TzecISIAQYCb_fDmckzcTj4UsRzMjFLQkoW31HKMlBuc5f2--OJgzXr_rVfOw-X2_vmt3-z_b9a9da3gnSisE4EAHMXFA1gPWzwTIyfZ0spJKFNaCpqLvnQYLrJPOjhKHgXZoNGjeXTXbS6-N8KSekw-QTiqCV-cgpkcFqfh6pepBj4Y7YwxHwQyfJKJ1jLPR9cBgrF300mVSzDmh--hjVL1hUhWTOmNSF0zdK5mKh-s</recordid><startdate>20240901</startdate><enddate>20240901</enddate><creator>McCracken, Kevin</creator><creator>Johnston, Haley</creator><creator>McCracken, Katherine</creator><creator>Olson, Riley</creator><creator>Otero Soberon, Jose Antonio</creator><creator>Turpo Aroquipa, Renzo Hernan</creator><creator>Alza, Luis</creator><general>Resilience Alliance</general><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope></search><sort><creationdate>20240901</creationdate><title>Comparability of hemoglobin concentration measurements from the HemoCue Hb201+ and Hb801 in birds and a mammal with and without nucleated red-blood cells</title><author>McCracken, Kevin ; Johnston, Haley ; McCracken, Katherine ; Olson, Riley ; Otero Soberon, Jose Antonio ; Turpo Aroquipa, Renzo Hernan ; Alza, Luis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c234t-44ae707492ae16ae0014a59d609d505e4ddab0466fbada135fd85e7703ecbab23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>avian hematology</topic><topic>hemocue</topic><topic>hemoglobin concentration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>McCracken, Kevin</creatorcontrib><creatorcontrib>Johnston, Haley</creatorcontrib><creatorcontrib>McCracken, Katherine</creatorcontrib><creatorcontrib>Olson, Riley</creatorcontrib><creatorcontrib>Otero Soberon, Jose Antonio</creatorcontrib><creatorcontrib>Turpo Aroquipa, Renzo Hernan</creatorcontrib><creatorcontrib>Alza, Luis</creatorcontrib><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of field ornithology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>McCracken, Kevin</au><au>Johnston, Haley</au><au>McCracken, Katherine</au><au>Olson, Riley</au><au>Otero Soberon, Jose Antonio</au><au>Turpo Aroquipa, Renzo Hernan</au><au>Alza, Luis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparability of hemoglobin concentration measurements from the HemoCue Hb201+ and Hb801 in birds and a mammal with and without nucleated red-blood cells</atitle><jtitle>Journal of field ornithology</jtitle><date>2024-09-01</date><risdate>2024</risdate><volume>95</volume><issue>3</issue><spage>5</spage><pages>5-</pages><artnum>art5</artnum><issn>1557-9263</issn><eissn>1557-9263</eissn><abstract>HemoCue analyzers are standard point-of-care devices for measuring blood hemoglobin concentration ([Hb]). The utility of these photometers has been demonstrated for all vertebrate lineages including birds, yet because most vertebrates except mammals possess nucleated red-blood cells, their [Hb] readings are inflated upward in these taxa and require a correction factor relative to the reference calibration. We field tested the newest of these analyzers, Hb801, against its predecessor, the Hb201+. Because of differences in the photometry methods, these two analyzers were not found to be equivalent for taxa with nucleated red-blood cells, such as birds. Whereas a correction factor of 1.0–1.4 g/dL is required for the Hb201+, it may be that no correction factor is required for the Hb801. Further study of the Hb801 relative to a gold-standard reference in non-mammalian lineages is warranted.</abstract><pub>Resilience Alliance</pub><doi>10.5751/JFO-00493-950305</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1557-9263
ispartof Journal of field ornithology, 2024-09, Vol.95 (3), p.5, Article art5
issn 1557-9263
1557-9263
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_6ab8c2fccc2e41c295eedf1218f6a1a8
source EZB Electronic Journals Library
subjects avian hematology
hemocue
hemoglobin concentration
title Comparability of hemoglobin concentration measurements from the HemoCue Hb201+ and Hb801 in birds and a mammal with and without nucleated red-blood cells
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T20%3A36%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-doaj_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparability%20of%20hemoglobin%20concentration%20measurements%20from%20the%20HemoCue%20Hb201+%20and%20Hb801%20in%20birds%20and%20a%20mammal%20with%20and%20without%20nucleated%20red-blood%20cells&rft.jtitle=Journal%20of%20field%20ornithology&rft.au=McCracken,%20Kevin&rft.date=2024-09-01&rft.volume=95&rft.issue=3&rft.spage=5&rft.pages=5-&rft.artnum=art5&rft.issn=1557-9263&rft.eissn=1557-9263&rft_id=info:doi/10.5751/JFO-00493-950305&rft_dat=%3Cdoaj_cross%3Eoai_doaj_org_article_6ab8c2fccc2e41c295eedf1218f6a1a8%3C/doaj_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c234t-44ae707492ae16ae0014a59d609d505e4ddab0466fbada135fd85e7703ecbab23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true