Prolonged air leak after IPC insertion: An unusual complication
Indwelling pleural catheters [IPC] have an important role in the management of malignant pleural effusions. We report the development of a significant air leak following IPC insertion with resultant extensive subcutaneous emphysema. The air leak developed, presumably, as a result of visceral pleural...
Saved in:
Published in: | Respiratory medicine case reports 2020-01, Vol.31, p.101257, Article 101257 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c416t-d2eba11d977b6d69b62cdcb83ea66821563bad65f9e0332de0344173aac0ef9c3 |
container_end_page | |
container_issue | |
container_start_page | 101257 |
container_title | Respiratory medicine case reports |
container_volume | 31 |
creator | Bhatnagar, Malvika Slight, Robert Prasad, Arun Brahmanya Stanton, Andrew Ewing |
description | Indwelling pleural catheters [IPC] have an important role in the management of malignant pleural effusions. We report the development of a significant air leak following IPC insertion with resultant extensive subcutaneous emphysema. The air leak developed, presumably, as a result of visceral pleural disruption, which occurred at the time of vacuum drainage of pleural fluid after IPC placement and not due to lung injury during insertion. The patient required insertion of a large bore intercostal drain connected to low-pressure negative suction. He was eventually discharged home with the aid of an ambulatory system. Although commonly seen in the surgical setting, we believe emergency and respiratory physicians should be aware of the risk of such a complication, and the challenges in its management. |
doi_str_mv | 10.1016/j.rmcr.2020.101257 |
format | article |
fullrecord | <record><control><sourceid>elsevier_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_6ea4c383752b43b6b09e8a4de64733ae</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2213007120304718</els_id><doaj_id>oai_doaj_org_article_6ea4c383752b43b6b09e8a4de64733ae</doaj_id><sourcerecordid>S2213007120304718</sourcerecordid><originalsourceid>FETCH-LOGICAL-c416t-d2eba11d977b6d69b62cdcb83ea66821563bad65f9e0332de0344173aac0ef9c3</originalsourceid><addsrcrecordid>eNp9kV1LwzAUhoMoOqZ_wKv-gc18tEkrosjwYyDohV6Hk-R0ZnbNSLuB_95sFdEbc5GEc3geTvIScs7olFEmL5bTuLJxyinfF3ihDsiIcyYmlCp2-Ot-Qs66bknTUmVFC35MToRISEXpiNy8xNCEdoEuAx-zBuEjg7rHmM1fZplvO4y9D-1ldttmm3bTbaDJbFitG29h1zglRzU0HZ59n2Pydn_3OnucPD0_zGe3TxObM9lPHEcDjLlKKSOdrIzk1llTCgQpS84KKQw4WdQVUiG4S3ueMyUALMW6smJM5oPXBVjqdfQriJ86gNf7QogLDWlS26CWCLkVpVAFN7kw0tAKS8gdylwJAZhc14NrvTErdBbbPkLzR_q30_p3vQhbrQpVFkkyJnwQ2Bi6LmL9wzKqd-nopd6lo3fp6CGdBF0NEKZv2nqMurMeW4vOR7R9eof_D_8CmVaXKg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Prolonged air leak after IPC insertion: An unusual complication</title><source>ScienceDirect Journals</source><source>PubMed Central</source><creator>Bhatnagar, Malvika ; Slight, Robert ; Prasad, Arun Brahmanya ; Stanton, Andrew Ewing</creator><creatorcontrib>Bhatnagar, Malvika ; Slight, Robert ; Prasad, Arun Brahmanya ; Stanton, Andrew Ewing</creatorcontrib><description>Indwelling pleural catheters [IPC] have an important role in the management of malignant pleural effusions. We report the development of a significant air leak following IPC insertion with resultant extensive subcutaneous emphysema. The air leak developed, presumably, as a result of visceral pleural disruption, which occurred at the time of vacuum drainage of pleural fluid after IPC placement and not due to lung injury during insertion. The patient required insertion of a large bore intercostal drain connected to low-pressure negative suction. He was eventually discharged home with the aid of an ambulatory system. Although commonly seen in the surgical setting, we believe emergency and respiratory physicians should be aware of the risk of such a complication, and the challenges in its management.</description><identifier>ISSN: 2213-0071</identifier><identifier>EISSN: 2213-0071</identifier><identifier>DOI: 10.1016/j.rmcr.2020.101257</identifier><identifier>PMID: 33101900</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Air leak ; Case Report ; Indwelling pleural catheter ; Negative suction ; Visceral pleural disruption</subject><ispartof>Respiratory medicine case reports, 2020-01, Vol.31, p.101257, Article 101257</ispartof><rights>2021 The Authors</rights><rights>2020 Published by Elsevier Ltd. 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c416t-d2eba11d977b6d69b62cdcb83ea66821563bad65f9e0332de0344173aac0ef9c3</cites><orcidid>0000-0003-1244-0735 ; 0000-0002-9138-2408</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7578547/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2213007120304718$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,3549,27924,27925,45780,53791,53793</link.rule.ids></links><search><creatorcontrib>Bhatnagar, Malvika</creatorcontrib><creatorcontrib>Slight, Robert</creatorcontrib><creatorcontrib>Prasad, Arun Brahmanya</creatorcontrib><creatorcontrib>Stanton, Andrew Ewing</creatorcontrib><title>Prolonged air leak after IPC insertion: An unusual complication</title><title>Respiratory medicine case reports</title><description>Indwelling pleural catheters [IPC] have an important role in the management of malignant pleural effusions. We report the development of a significant air leak following IPC insertion with resultant extensive subcutaneous emphysema. The air leak developed, presumably, as a result of visceral pleural disruption, which occurred at the time of vacuum drainage of pleural fluid after IPC placement and not due to lung injury during insertion. The patient required insertion of a large bore intercostal drain connected to low-pressure negative suction. He was eventually discharged home with the aid of an ambulatory system. Although commonly seen in the surgical setting, we believe emergency and respiratory physicians should be aware of the risk of such a complication, and the challenges in its management.</description><subject>Air leak</subject><subject>Case Report</subject><subject>Indwelling pleural catheter</subject><subject>Negative suction</subject><subject>Visceral pleural disruption</subject><issn>2213-0071</issn><issn>2213-0071</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNp9kV1LwzAUhoMoOqZ_wKv-gc18tEkrosjwYyDohV6Hk-R0ZnbNSLuB_95sFdEbc5GEc3geTvIScs7olFEmL5bTuLJxyinfF3ihDsiIcyYmlCp2-Ot-Qs66bknTUmVFC35MToRISEXpiNy8xNCEdoEuAx-zBuEjg7rHmM1fZplvO4y9D-1ldttmm3bTbaDJbFitG29h1zglRzU0HZ59n2Pydn_3OnucPD0_zGe3TxObM9lPHEcDjLlKKSOdrIzk1llTCgQpS84KKQw4WdQVUiG4S3ueMyUALMW6smJM5oPXBVjqdfQriJ86gNf7QogLDWlS26CWCLkVpVAFN7kw0tAKS8gdylwJAZhc14NrvTErdBbbPkLzR_q30_p3vQhbrQpVFkkyJnwQ2Bi6LmL9wzKqd-nopd6lo3fp6CGdBF0NEKZv2nqMurMeW4vOR7R9eof_D_8CmVaXKg</recordid><startdate>20200101</startdate><enddate>20200101</enddate><creator>Bhatnagar, Malvika</creator><creator>Slight, Robert</creator><creator>Prasad, Arun Brahmanya</creator><creator>Stanton, Andrew Ewing</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0003-1244-0735</orcidid><orcidid>https://orcid.org/0000-0002-9138-2408</orcidid></search><sort><creationdate>20200101</creationdate><title>Prolonged air leak after IPC insertion: An unusual complication</title><author>Bhatnagar, Malvika ; Slight, Robert ; Prasad, Arun Brahmanya ; Stanton, Andrew Ewing</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c416t-d2eba11d977b6d69b62cdcb83ea66821563bad65f9e0332de0344173aac0ef9c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Air leak</topic><topic>Case Report</topic><topic>Indwelling pleural catheter</topic><topic>Negative suction</topic><topic>Visceral pleural disruption</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bhatnagar, Malvika</creatorcontrib><creatorcontrib>Slight, Robert</creatorcontrib><creatorcontrib>Prasad, Arun Brahmanya</creatorcontrib><creatorcontrib>Stanton, Andrew Ewing</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Respiratory medicine case reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bhatnagar, Malvika</au><au>Slight, Robert</au><au>Prasad, Arun Brahmanya</au><au>Stanton, Andrew Ewing</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Prolonged air leak after IPC insertion: An unusual complication</atitle><jtitle>Respiratory medicine case reports</jtitle><date>2020-01-01</date><risdate>2020</risdate><volume>31</volume><spage>101257</spage><pages>101257-</pages><artnum>101257</artnum><issn>2213-0071</issn><eissn>2213-0071</eissn><abstract>Indwelling pleural catheters [IPC] have an important role in the management of malignant pleural effusions. We report the development of a significant air leak following IPC insertion with resultant extensive subcutaneous emphysema. The air leak developed, presumably, as a result of visceral pleural disruption, which occurred at the time of vacuum drainage of pleural fluid after IPC placement and not due to lung injury during insertion. The patient required insertion of a large bore intercostal drain connected to low-pressure negative suction. He was eventually discharged home with the aid of an ambulatory system. Although commonly seen in the surgical setting, we believe emergency and respiratory physicians should be aware of the risk of such a complication, and the challenges in its management.</abstract><pub>Elsevier Ltd</pub><pmid>33101900</pmid><doi>10.1016/j.rmcr.2020.101257</doi><orcidid>https://orcid.org/0000-0003-1244-0735</orcidid><orcidid>https://orcid.org/0000-0002-9138-2408</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2213-0071 |
ispartof | Respiratory medicine case reports, 2020-01, Vol.31, p.101257, Article 101257 |
issn | 2213-0071 2213-0071 |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_6ea4c383752b43b6b09e8a4de64733ae |
source | ScienceDirect Journals; PubMed Central |
subjects | Air leak Case Report Indwelling pleural catheter Negative suction Visceral pleural disruption |
title | Prolonged air leak after IPC insertion: An unusual complication |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T01%3A16%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Prolonged%20air%20leak%20after%20IPC%20insertion:%20An%20unusual%20complication&rft.jtitle=Respiratory%20medicine%20case%20reports&rft.au=Bhatnagar,%20Malvika&rft.date=2020-01-01&rft.volume=31&rft.spage=101257&rft.pages=101257-&rft.artnum=101257&rft.issn=2213-0071&rft.eissn=2213-0071&rft_id=info:doi/10.1016/j.rmcr.2020.101257&rft_dat=%3Celsevier_doaj_%3ES2213007120304718%3C/elsevier_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c416t-d2eba11d977b6d69b62cdcb83ea66821563bad65f9e0332de0344173aac0ef9c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/33101900&rfr_iscdi=true |