Loading…

Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing

Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and...

Full description

Saved in:
Bibliographic Details
Published in:Dental research journal 2012-05, Vol.9 (3), p.321-327
Main Authors: Toodehzaeim, Mohammad Hossein, Kazemi, Alireza Danesh, Aghili, Hossein Agha, Barzegar, Kazem, Fallahtafti, Taranom
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 327
container_issue 3
container_start_page 321
container_title Dental research journal
container_volume 9
creator Toodehzaeim, Mohammad Hossein
Kazemi, Alireza Danesh
Aghili, Hossein Agha
Barzegar, Kazem
Fallahtafti, Taranom
description Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and plasma arc system. MATERIALS AND MEHODS: This was an experimental in vitro study. A total of 60 intact premolar teeth were collected and divided into four groups. Stainless steel orthodontic brackets were bonded to them. In groups 1 and 2, curing was done using halogen light given for 20 seconds from two and four angles. In groups 3 and 4, curing was carried out using the plasma arc system for 6 seconds from two and four angles. The shear bond strength was recorded by Instron. The statistics of ANOVA, Tukey's test, and T-test were used in data analysis. There was a statistically significant difference in shear bond strength among the four groups (P = 0.043) and between group 1 with group 2 (P = 0.035). Yet, there was no statistically significant difference between brackets bonded with plasma arc and those bonded with halogen light or between the two groups of plasma arc. Using the plasma arc system is superior to other methods due to reduced curing time. Also, since in using the halogen light system, an increase in curing periods from different angles resulted in a significant increase in shear bond strength; it is advisable to apply the halogen light from different angles.
doi_str_mv 10.4103/1735-3327.99835
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_7113863d221b475f9d7dbab7440460fa</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_7113863d221b475f9d7dbab7440460fa</doaj_id><sourcerecordid>2753892421</sourcerecordid><originalsourceid>FETCH-LOGICAL-d2050-e92b04be65044b093d1974f7280d58e9f6f4007f11a6cb49d807015c968f54d13</originalsourceid><addsrcrecordid>eNpdkc1v1DAQxS0EotuFMzdkiQuXlPF3fEFCKyiVKnGBs2XHTuIlsRc7AfHfk35QUU4jvXnz08w8hF4RuOAE2DuimGgYo-pC65aJJ2hHAdoGqBBP0e6he4bOaz0CSKKJeI7OKINWKaZ3KB7yfLIl1pxw7nEdgy3Y5eRxXUpIwzLeyLksY_Y5LbHDrtjue1jqrSt4_CtuntFOeQgJ223wNNk6W2xLh6c4jAvu1hLT8AI96-1Uw8v7ukffPn38evjcXH-5vDp8uG48BQFN0NQBd0EK4NyBZp5oxXtFW_CiDbqXPQdQPSFWdo5r34ICIjot215wT9geXd1xfbZHcypxtuW3yTaaWyGXwdiyHTIFowhhrWSeUuK4Er32yjvrFOfAJfR2Y72_Y51WNwffhbQUOz2CPu6kOJoh_zSMS60BNsDbe0DJP9ZQFzPH2oVpsinktRpCCFcguL6xvvnPesxrSdurzJZ0SySBLbI9ev3vRg-r_E2U_QFoB6H1</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1038161077</pqid></control><display><type>article</type><title>Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>PubMed Central</source><creator>Toodehzaeim, Mohammad Hossein ; Kazemi, Alireza Danesh ; Aghili, Hossein Agha ; Barzegar, Kazem ; Fallahtafti, Taranom</creator><creatorcontrib>Toodehzaeim, Mohammad Hossein ; Kazemi, Alireza Danesh ; Aghili, Hossein Agha ; Barzegar, Kazem ; Fallahtafti, Taranom</creatorcontrib><description>Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and plasma arc system. MATERIALS AND MEHODS: This was an experimental in vitro study. A total of 60 intact premolar teeth were collected and divided into four groups. Stainless steel orthodontic brackets were bonded to them. In groups 1 and 2, curing was done using halogen light given for 20 seconds from two and four angles. In groups 3 and 4, curing was carried out using the plasma arc system for 6 seconds from two and four angles. The shear bond strength was recorded by Instron. The statistics of ANOVA, Tukey's test, and T-test were used in data analysis. There was a statistically significant difference in shear bond strength among the four groups (P = 0.043) and between group 1 with group 2 (P = 0.035). Yet, there was no statistically significant difference between brackets bonded with plasma arc and those bonded with halogen light or between the two groups of plasma arc. Using the plasma arc system is superior to other methods due to reduced curing time. Also, since in using the halogen light system, an increase in curing periods from different angles resulted in a significant increase in shear bond strength; it is advisable to apply the halogen light from different angles.</description><identifier>ISSN: 1735-3327</identifier><identifier>EISSN: 2008-0255</identifier><identifier>DOI: 10.4103/1735-3327.99835</identifier><identifier>PMID: 23087739</identifier><language>eng</language><publisher>Iran: Medknow Publications &amp; Media Pvt. Ltd</publisher><subject>Halogen light ; Original ; plasma arc ; shear bond strength</subject><ispartof>Dental research journal, 2012-05, Vol.9 (3), p.321-327</ispartof><rights>Copyright Isfahan University of Medical Sciences May 2012</rights><rights>Copyright: © Dental Research Journal 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3469900/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/1038161077?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25752,27923,27924,37011,37012,44589,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23087739$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Toodehzaeim, Mohammad Hossein</creatorcontrib><creatorcontrib>Kazemi, Alireza Danesh</creatorcontrib><creatorcontrib>Aghili, Hossein Agha</creatorcontrib><creatorcontrib>Barzegar, Kazem</creatorcontrib><creatorcontrib>Fallahtafti, Taranom</creatorcontrib><title>Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing</title><title>Dental research journal</title><addtitle>Dent Res J (Isfahan)</addtitle><description>Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and plasma arc system. MATERIALS AND MEHODS: This was an experimental in vitro study. A total of 60 intact premolar teeth were collected and divided into four groups. Stainless steel orthodontic brackets were bonded to them. In groups 1 and 2, curing was done using halogen light given for 20 seconds from two and four angles. In groups 3 and 4, curing was carried out using the plasma arc system for 6 seconds from two and four angles. The shear bond strength was recorded by Instron. The statistics of ANOVA, Tukey's test, and T-test were used in data analysis. There was a statistically significant difference in shear bond strength among the four groups (P = 0.043) and between group 1 with group 2 (P = 0.035). Yet, there was no statistically significant difference between brackets bonded with plasma arc and those bonded with halogen light or between the two groups of plasma arc. Using the plasma arc system is superior to other methods due to reduced curing time. Also, since in using the halogen light system, an increase in curing periods from different angles resulted in a significant increase in shear bond strength; it is advisable to apply the halogen light from different angles.</description><subject>Halogen light</subject><subject>Original</subject><subject>plasma arc</subject><subject>shear bond strength</subject><issn>1735-3327</issn><issn>2008-0255</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><sourceid>DOA</sourceid><recordid>eNpdkc1v1DAQxS0EotuFMzdkiQuXlPF3fEFCKyiVKnGBs2XHTuIlsRc7AfHfk35QUU4jvXnz08w8hF4RuOAE2DuimGgYo-pC65aJJ2hHAdoGqBBP0e6he4bOaz0CSKKJeI7OKINWKaZ3KB7yfLIl1pxw7nEdgy3Y5eRxXUpIwzLeyLksY_Y5LbHDrtjue1jqrSt4_CtuntFOeQgJ223wNNk6W2xLh6c4jAvu1hLT8AI96-1Uw8v7ukffPn38evjcXH-5vDp8uG48BQFN0NQBd0EK4NyBZp5oxXtFW_CiDbqXPQdQPSFWdo5r34ICIjot215wT9geXd1xfbZHcypxtuW3yTaaWyGXwdiyHTIFowhhrWSeUuK4Er32yjvrFOfAJfR2Y72_Y51WNwffhbQUOz2CPu6kOJoh_zSMS60BNsDbe0DJP9ZQFzPH2oVpsinktRpCCFcguL6xvvnPesxrSdurzJZ0SySBLbI9ev3vRg-r_E2U_QFoB6H1</recordid><startdate>201205</startdate><enddate>201205</enddate><creator>Toodehzaeim, Mohammad Hossein</creator><creator>Kazemi, Alireza Danesh</creator><creator>Aghili, Hossein Agha</creator><creator>Barzegar, Kazem</creator><creator>Fallahtafti, Taranom</creator><general>Medknow Publications &amp; Media Pvt. Ltd</general><general>Medknow Publications &amp; Media Pvt Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>NPM</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>CWDGH</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>5PM</scope><scope>DOA</scope></search><sort><creationdate>201205</creationdate><title>Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing</title><author>Toodehzaeim, Mohammad Hossein ; Kazemi, Alireza Danesh ; Aghili, Hossein Agha ; Barzegar, Kazem ; Fallahtafti, Taranom</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-d2050-e92b04be65044b093d1974f7280d58e9f6f4007f11a6cb49d807015c968f54d13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Halogen light</topic><topic>Original</topic><topic>plasma arc</topic><topic>shear bond strength</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Toodehzaeim, Mohammad Hossein</creatorcontrib><creatorcontrib>Kazemi, Alireza Danesh</creatorcontrib><creatorcontrib>Aghili, Hossein Agha</creatorcontrib><creatorcontrib>Barzegar, Kazem</creatorcontrib><creatorcontrib>Fallahtafti, Taranom</creatorcontrib><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest - Health &amp; Medical Complete保健、医学与药学数据库</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>Middle East &amp; Africa Database</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><collection>DAOJ: Directory of Open Access Journals</collection><jtitle>Dental research journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Toodehzaeim, Mohammad Hossein</au><au>Kazemi, Alireza Danesh</au><au>Aghili, Hossein Agha</au><au>Barzegar, Kazem</au><au>Fallahtafti, Taranom</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing</atitle><jtitle>Dental research journal</jtitle><addtitle>Dent Res J (Isfahan)</addtitle><date>2012-05</date><risdate>2012</risdate><volume>9</volume><issue>3</issue><spage>321</spage><epage>327</epage><pages>321-327</pages><issn>1735-3327</issn><eissn>2008-0255</eissn><abstract>Reduced time and appropriate bond strength of brackets is one of the most important aspects of orthodontic treatments. Prolonged halogen light curing for bonding of brackets is undesirable, so the purpose of this study was to compare the shear bond strength of brackets bonded with halogen light and plasma arc system. MATERIALS AND MEHODS: This was an experimental in vitro study. A total of 60 intact premolar teeth were collected and divided into four groups. Stainless steel orthodontic brackets were bonded to them. In groups 1 and 2, curing was done using halogen light given for 20 seconds from two and four angles. In groups 3 and 4, curing was carried out using the plasma arc system for 6 seconds from two and four angles. The shear bond strength was recorded by Instron. The statistics of ANOVA, Tukey's test, and T-test were used in data analysis. There was a statistically significant difference in shear bond strength among the four groups (P = 0.043) and between group 1 with group 2 (P = 0.035). Yet, there was no statistically significant difference between brackets bonded with plasma arc and those bonded with halogen light or between the two groups of plasma arc. Using the plasma arc system is superior to other methods due to reduced curing time. Also, since in using the halogen light system, an increase in curing periods from different angles resulted in a significant increase in shear bond strength; it is advisable to apply the halogen light from different angles.</abstract><cop>Iran</cop><pub>Medknow Publications &amp; Media Pvt. Ltd</pub><pmid>23087739</pmid><doi>10.4103/1735-3327.99835</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1735-3327
ispartof Dental research journal, 2012-05, Vol.9 (3), p.321-327
issn 1735-3327
2008-0255
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_7113863d221b475f9d7dbab7440460fa
source Publicly Available Content Database (Proquest) (PQ_SDU_P3); PubMed Central
subjects Halogen light
Original
plasma arc
shear bond strength
title Comparison of shear bond strength of orthodontic brackets bonded with halogen and plasma arc light curing
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T13%3A15%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20shear%20bond%20strength%20of%20orthodontic%20brackets%20bonded%20with%20halogen%20and%20plasma%20arc%20light%20curing&rft.jtitle=Dental%20research%20journal&rft.au=Toodehzaeim,%20Mohammad%20Hossein&rft.date=2012-05&rft.volume=9&rft.issue=3&rft.spage=321&rft.epage=327&rft.pages=321-327&rft.issn=1735-3327&rft.eissn=2008-0255&rft_id=info:doi/10.4103/1735-3327.99835&rft_dat=%3Cproquest_doaj_%3E2753892421%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-d2050-e92b04be65044b093d1974f7280d58e9f6f4007f11a6cb49d807015c968f54d13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1038161077&rft_id=info:pmid/23087739&rfr_iscdi=true