Loading…
GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range
A collaboration between CNRS-Grenoble and IBS-CAPP Daejeon plans to build a Sikivie’s type haloscope for axion/ALPs dark matter search at the Dine-Fischler-Srednicki-Zhitnitskii sensitivity for the 300–600 MHz range. It will be based on the large-bore superconducting “outsert” coil of the Grenoble h...
Saved in:
Published in: | Frontiers in physics 2024-04, Vol.12 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873 |
---|---|
cites | cdi_FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873 |
container_end_page | |
container_issue | |
container_start_page | |
container_title | Frontiers in physics |
container_volume | 12 |
creator | Pugnat, Pierre Camus, Philippe Kwon, Ohjoon Ballou, Rafik Bruyère, Cyril Byun, Heesu Chung, Woohyun Grenet, Thierry Perrier, Pierre Semertzidis, Yannis K. Talarmin, Arthur Vessaire, Jérémy |
description | A collaboration between CNRS-Grenoble and IBS-CAPP Daejeon plans to build a Sikivie’s type haloscope for axion/ALPs dark matter search at the Dine-Fischler-Srednicki-Zhitnitskii sensitivity for the 300–600 MHz range. It will be based on the large-bore superconducting “outsert” coil of the Grenoble hybrid magnet, providing a central magnetic field up to 9 T in an 810-mm warm bore diameter. This magnet has recently been successfully powered up to 8.5 T, achieving the first step of the electrical commissioning phase. The design principles of the cryostat with its double dilution refrigerators to cool below 50 mK, the light Cu RF cavity of 700-mm diameter, and its tuning rod(s) and the first stages of the measurement chain are presented. Perspectives for the targeted sensitivity assuming less than a 2-year integration time are given. |
doi_str_mv | 10.3389/fphy.2024.1358810 |
format | article |
fullrecord | <record><control><sourceid>hal_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_77a681f46fba4eb8a6cedf1970ab785b</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_77a681f46fba4eb8a6cedf1970ab785b</doaj_id><sourcerecordid>oai_HAL_hal_04558635v1</sourcerecordid><originalsourceid>FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873</originalsourceid><addsrcrecordid>eNpVkU1OwzAQhSMEEgg4ADtvWaT4Jz_OsqqgrVSJLgCxsyb2mBhKUtmm0B134DqcgUNwElKKEKxmNO-9Txq9JDlhdCCErM7sslkPOOXZgIlcSkZ3kgPOqyLNeHa7-2ffT45DuKeUMp5XkmcHiRn74QQW6Wg4nxPbeQIvrmuJAf9AHiFG9CQgeN2QZxcb8tQuPWo02EY0vdIGF93KxTVxLYkNEvb5-ibIxzve9PEQiIf2Do-SPQuLgMc_8zC5vji_Gk3S2eV4OhrOUi2kjCloZpGCpAy4QaAl50gNCMao1Ca3Ne0lq7k0nMpK6KqQYBhWpkLNSlmKw2S65ZoO7tXSu0fwa9WBU9-Hzt8p8NHpBaqyhEIymxW2hgxrCUX_lWVVSaEuZV73rNMtq4HFP9RkOFObG83yXBYiX7Hey7Ze7bsQPNrfAKNq05DaNKQ2DamfhsQXVD6GFQ</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range</title><source>ROAD: Directory of Open Access Scholarly Resources</source><creator>Pugnat, Pierre ; Camus, Philippe ; Kwon, Ohjoon ; Ballou, Rafik ; Bruyère, Cyril ; Byun, Heesu ; Chung, Woohyun ; Grenet, Thierry ; Perrier, Pierre ; Semertzidis, Yannis K. ; Talarmin, Arthur ; Vessaire, Jérémy</creator><creatorcontrib>Pugnat, Pierre ; Camus, Philippe ; Kwon, Ohjoon ; Ballou, Rafik ; Bruyère, Cyril ; Byun, Heesu ; Chung, Woohyun ; Grenet, Thierry ; Perrier, Pierre ; Semertzidis, Yannis K. ; Talarmin, Arthur ; Vessaire, Jérémy</creatorcontrib><description>A collaboration between CNRS-Grenoble and IBS-CAPP Daejeon plans to build a Sikivie’s type haloscope for axion/ALPs dark matter search at the Dine-Fischler-Srednicki-Zhitnitskii sensitivity for the 300–600 MHz range. It will be based on the large-bore superconducting “outsert” coil of the Grenoble hybrid magnet, providing a central magnetic field up to 9 T in an 810-mm warm bore diameter. This magnet has recently been successfully powered up to 8.5 T, achieving the first step of the electrical commissioning phase. The design principles of the cryostat with its double dilution refrigerators to cool below 50 mK, the light Cu RF cavity of 700-mm diameter, and its tuning rod(s) and the first stages of the measurement chain are presented. Perspectives for the targeted sensitivity assuming less than a 2-year integration time are given.</description><identifier>ISSN: 2296-424X</identifier><identifier>EISSN: 2296-424X</identifier><identifier>DOI: 10.3389/fphy.2024.1358810</identifier><language>eng</language><publisher>Frontiers</publisher><subject>ALPS ; Astrophysics ; axion ; dark matter ; haloscope ; High Energy Physics - Experiment ; large-bore superconducting magnets ; Physics ; RF cavities</subject><ispartof>Frontiers in physics, 2024-04, Vol.12</ispartof><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873</citedby><cites>FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873</cites><orcidid>0000-0002-9308-1860 ; 0000-0003-0488-0060</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://hal.science/hal-04558635$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Pugnat, Pierre</creatorcontrib><creatorcontrib>Camus, Philippe</creatorcontrib><creatorcontrib>Kwon, Ohjoon</creatorcontrib><creatorcontrib>Ballou, Rafik</creatorcontrib><creatorcontrib>Bruyère, Cyril</creatorcontrib><creatorcontrib>Byun, Heesu</creatorcontrib><creatorcontrib>Chung, Woohyun</creatorcontrib><creatorcontrib>Grenet, Thierry</creatorcontrib><creatorcontrib>Perrier, Pierre</creatorcontrib><creatorcontrib>Semertzidis, Yannis K.</creatorcontrib><creatorcontrib>Talarmin, Arthur</creatorcontrib><creatorcontrib>Vessaire, Jérémy</creatorcontrib><title>GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range</title><title>Frontiers in physics</title><description>A collaboration between CNRS-Grenoble and IBS-CAPP Daejeon plans to build a Sikivie’s type haloscope for axion/ALPs dark matter search at the Dine-Fischler-Srednicki-Zhitnitskii sensitivity for the 300–600 MHz range. It will be based on the large-bore superconducting “outsert” coil of the Grenoble hybrid magnet, providing a central magnetic field up to 9 T in an 810-mm warm bore diameter. This magnet has recently been successfully powered up to 8.5 T, achieving the first step of the electrical commissioning phase. The design principles of the cryostat with its double dilution refrigerators to cool below 50 mK, the light Cu RF cavity of 700-mm diameter, and its tuning rod(s) and the first stages of the measurement chain are presented. Perspectives for the targeted sensitivity assuming less than a 2-year integration time are given.</description><subject>ALPS</subject><subject>Astrophysics</subject><subject>axion</subject><subject>dark matter</subject><subject>haloscope</subject><subject>High Energy Physics - Experiment</subject><subject>large-bore superconducting magnets</subject><subject>Physics</subject><subject>RF cavities</subject><issn>2296-424X</issn><issn>2296-424X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpVkU1OwzAQhSMEEgg4ADtvWaT4Jz_OsqqgrVSJLgCxsyb2mBhKUtmm0B134DqcgUNwElKKEKxmNO-9Txq9JDlhdCCErM7sslkPOOXZgIlcSkZ3kgPOqyLNeHa7-2ffT45DuKeUMp5XkmcHiRn74QQW6Wg4nxPbeQIvrmuJAf9AHiFG9CQgeN2QZxcb8tQuPWo02EY0vdIGF93KxTVxLYkNEvb5-ibIxzve9PEQiIf2Do-SPQuLgMc_8zC5vji_Gk3S2eV4OhrOUi2kjCloZpGCpAy4QaAl50gNCMao1Ca3Ne0lq7k0nMpK6KqQYBhWpkLNSlmKw2S65ZoO7tXSu0fwa9WBU9-Hzt8p8NHpBaqyhEIymxW2hgxrCUX_lWVVSaEuZV73rNMtq4HFP9RkOFObG83yXBYiX7Hey7Ze7bsQPNrfAKNq05DaNKQ2DamfhsQXVD6GFQ</recordid><startdate>20240416</startdate><enddate>20240416</enddate><creator>Pugnat, Pierre</creator><creator>Camus, Philippe</creator><creator>Kwon, Ohjoon</creator><creator>Ballou, Rafik</creator><creator>Bruyère, Cyril</creator><creator>Byun, Heesu</creator><creator>Chung, Woohyun</creator><creator>Grenet, Thierry</creator><creator>Perrier, Pierre</creator><creator>Semertzidis, Yannis K.</creator><creator>Talarmin, Arthur</creator><creator>Vessaire, Jérémy</creator><general>Frontiers</general><general>Frontiers Media S.A</general><scope>AAYXX</scope><scope>CITATION</scope><scope>1XC</scope><scope>VOOES</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-9308-1860</orcidid><orcidid>https://orcid.org/0000-0003-0488-0060</orcidid></search><sort><creationdate>20240416</creationdate><title>GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range</title><author>Pugnat, Pierre ; Camus, Philippe ; Kwon, Ohjoon ; Ballou, Rafik ; Bruyère, Cyril ; Byun, Heesu ; Chung, Woohyun ; Grenet, Thierry ; Perrier, Pierre ; Semertzidis, Yannis K. ; Talarmin, Arthur ; Vessaire, Jérémy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>ALPS</topic><topic>Astrophysics</topic><topic>axion</topic><topic>dark matter</topic><topic>haloscope</topic><topic>High Energy Physics - Experiment</topic><topic>large-bore superconducting magnets</topic><topic>Physics</topic><topic>RF cavities</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pugnat, Pierre</creatorcontrib><creatorcontrib>Camus, Philippe</creatorcontrib><creatorcontrib>Kwon, Ohjoon</creatorcontrib><creatorcontrib>Ballou, Rafik</creatorcontrib><creatorcontrib>Bruyère, Cyril</creatorcontrib><creatorcontrib>Byun, Heesu</creatorcontrib><creatorcontrib>Chung, Woohyun</creatorcontrib><creatorcontrib>Grenet, Thierry</creatorcontrib><creatorcontrib>Perrier, Pierre</creatorcontrib><creatorcontrib>Semertzidis, Yannis K.</creatorcontrib><creatorcontrib>Talarmin, Arthur</creatorcontrib><creatorcontrib>Vessaire, Jérémy</creatorcontrib><collection>CrossRef</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Frontiers in physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pugnat, Pierre</au><au>Camus, Philippe</au><au>Kwon, Ohjoon</au><au>Ballou, Rafik</au><au>Bruyère, Cyril</au><au>Byun, Heesu</au><au>Chung, Woohyun</au><au>Grenet, Thierry</au><au>Perrier, Pierre</au><au>Semertzidis, Yannis K.</au><au>Talarmin, Arthur</au><au>Vessaire, Jérémy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range</atitle><jtitle>Frontiers in physics</jtitle><date>2024-04-16</date><risdate>2024</risdate><volume>12</volume><issn>2296-424X</issn><eissn>2296-424X</eissn><abstract>A collaboration between CNRS-Grenoble and IBS-CAPP Daejeon plans to build a Sikivie’s type haloscope for axion/ALPs dark matter search at the Dine-Fischler-Srednicki-Zhitnitskii sensitivity for the 300–600 MHz range. It will be based on the large-bore superconducting “outsert” coil of the Grenoble hybrid magnet, providing a central magnetic field up to 9 T in an 810-mm warm bore diameter. This magnet has recently been successfully powered up to 8.5 T, achieving the first step of the electrical commissioning phase. The design principles of the cryostat with its double dilution refrigerators to cool below 50 mK, the light Cu RF cavity of 700-mm diameter, and its tuning rod(s) and the first stages of the measurement chain are presented. Perspectives for the targeted sensitivity assuming less than a 2-year integration time are given.</abstract><pub>Frontiers</pub><doi>10.3389/fphy.2024.1358810</doi><orcidid>https://orcid.org/0000-0002-9308-1860</orcidid><orcidid>https://orcid.org/0000-0003-0488-0060</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2296-424X |
ispartof | Frontiers in physics, 2024-04, Vol.12 |
issn | 2296-424X 2296-424X |
language | eng |
recordid | cdi_doaj_primary_oai_doaj_org_article_77a681f46fba4eb8a6cedf1970ab785b |
source | ROAD: Directory of Open Access Scholarly Resources |
subjects | ALPS Astrophysics axion dark matter haloscope High Energy Physics - Experiment large-bore superconducting magnets Physics RF cavities |
title | GrAHal-CAPP for axion dark matter search with unprecedented sensitivity in the 1–3 μeV mass range |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T21%3A26%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-hal_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=GrAHal-CAPP%20for%20axion%20dark%20matter%20search%20with%20unprecedented%20sensitivity%20in%20the%201%E2%80%933%20%CE%BCeV%20mass%20range&rft.jtitle=Frontiers%20in%20physics&rft.au=Pugnat,%20Pierre&rft.date=2024-04-16&rft.volume=12&rft.issn=2296-424X&rft.eissn=2296-424X&rft_id=info:doi/10.3389/fphy.2024.1358810&rft_dat=%3Chal_doaj_%3Eoai_HAL_hal_04558635v1%3C/hal_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c388t-ac1fe0a801a2dea0722e0da31108cd5fb0801fc28d20893c968ad1e9d9ec17873%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |