Loading…
Clinical outcomes of ultrathin biodegradable polymer-coated sirolimus-eluting stents in an all-comer population: One-year results from the T-FLEX registry including high-risk subgroups
OBJECTIVET-Flex registry was designed to investigate the safety and clinical performance of the ultrathin (60 µm) strut biodegradable polymer-coated sirolimus-eluting stent (SES) with a unique long dual Z (LDZ) link design on a cobalt-chromium stent platform (Sahajanand Medical Technologies Pvt. Ltd...
Saved in:
Published in: | Anatolian journal of cardiology 2021-10, Vol.25 (10), p.706-715 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVET-Flex registry was designed to investigate the safety and clinical performance of the ultrathin (60 µm) strut biodegradable polymer-coated sirolimus-eluting stent (SES) with a unique long dual Z (LDZ) link design on a cobalt-chromium stent platform (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) in a real-world all-comer population including high-risk subgroups. METHODSThis was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. A total of 1,203 patients treated with an ultrathin biodegradable polymer-coated SES, irrespective of lesion complexity, comorbidities, and acute presentation were analyzed from May 2016 to January 2017. The primary endpoint was the one-year incidence of target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction (TV-MI), and clinically-indicated target lesion revascularization (CI-TLR). Stent thrombosis was assessed as an additional safety endpoint. RESULTSAt the one-year follow-up, TLF was observed in 3.8% [95% confidence interval (CI) 2.9-5.1] patients, composed of 0.6% (95% CI: 0.3-1.3) cardiac death, 1.3% (95% CI: 0.8-2.2) TV-MI, and 1.9% (95% CI: 1.3-2.9) CI-TLR. In the high-risk subgroups, TLF at one-year was 6.8% (95% CI: 4.6-9.8) in patients with diabetes, 5.2% (95% CI: 3.4-8) in patients with small-vessel disease, 6.1% (95% CI: 3.9-9.6) in patients with ST-elevation myocardial infarction, and 4.5% (95% CI: 2.4-8.3) in patients with total occlusion. During follow-up, stent thrombosis was reported in 0.8% (95% CI: 0.4-1.5) patients in the overall population. CONCLUSIONLow event rates of TLF and stent thrombosis at one-year follow-up indicate that this ultrathin biodegradable polymer-coated SES has encouraging safety and clinical performance in real-world all-comer populations as well as in high-risk subgroups. |
---|---|
ISSN: | 2149-2263 2149-2271 |
DOI: | 10.5152/AnatolJCardiol.2021.78291 |