Loading…

Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol

An extraction-spectrophotometric method for determination of nickel at sub ppm level using 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the new extractant is described. The reagent reacts with nickel(II) at pH > 10 and form a 1:2 brown complex, which is extracted into chloroform. The complex...

Full description

Saved in:
Bibliographic Details
Published in:Bulletin of the Chemical Society of Ethiopia 2008-12, Vol.22 (3), p.323-329
Main Authors: Haji Shabani, A.M., Dadfarnia, S., Shahbaazi, Z., Jafari, A.A.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c340t-366a7d542e3db3bf9f02de27e14e1f2275fdbe9ef61b49ee190c355f4b06b73b3
cites
container_end_page 329
container_issue 3
container_start_page 323
container_title Bulletin of the Chemical Society of Ethiopia
container_volume 22
creator Haji Shabani, A.M.
Dadfarnia, S.
Shahbaazi, Z.
Jafari, A.A.
description An extraction-spectrophotometric method for determination of nickel at sub ppm level using 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the new extractant is described. The reagent reacts with nickel(II) at pH > 10 and form a 1:2 brown complex, which is extracted into chloroform. The complex has a maximum absorption at 421 nm with the molar absorptivity of 2.41 x 10 super(5) M super(-1) cm super(-1). Beer's law is obeyed over the range of 0.011-0.30 mu g mL super(-1). The Sandell's sensitivity for 0.001 absorbance unit is 5.34 x 10 super(-4) mu g cm super(-2). The relative standard deviation at 0.018 mu g mL super(-1) is 1.1% (n = 8). The procedure was successfully applied to determination of nickel in wastewater and standard alloy and the accuracy was determined by recovery experiment, independent analysis by furnace-AAS, and analysis of a certified reference martial.
doi_str_mv 10.4314/bcse.v22i3.61196
format article
fullrecord <record><control><sourceid>proquest_doaj_</sourceid><recordid>TN_cdi_doaj_primary_oai_doaj_org_article_7fa8bfed20f245a5bbb432f52bc3fd18</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_7fa8bfed20f245a5bbb432f52bc3fd18</doaj_id><sourcerecordid>20520043</sourcerecordid><originalsourceid>FETCH-LOGICAL-c340t-366a7d542e3db3bf9f02de27e14e1f2275fdbe9ef61b49ee190c355f4b06b73b3</originalsourceid><addsrcrecordid>eNpNkc1uFDEQhEcIJELgztEnBIdZ7LY9kzmiKJBIkbjACSHLP-2Ng2c82N7AvgTPHO8uQpy6u1T6SurquteMbgRn4r2xBTcPAIFvBsam4Ul3xihjPZ9APP1vf969KOWeUqB8lGfdn6vfNWtbQ1r6sqKtOa13qaYZaw6WOKyY57Dog4EkT5Zgf2AkupI52Jy2Wc8k4kOTwkJ-6eYmenFtKxVP566EZUug__YW-hmz1WttEbjsY2jg9K4l3e3j94OU4svumdex4Ku_87z7-vHqy-V1f_v5083lh9veckFrz4dBj04KQO4MN37yFBzCiEwg8wCj9M7ghH5gRkyIbKKWS-mFoYMZueHn3c2J65K-V2sOs857lXRQRyHlrdK5BhtRjV5fGI8OqAchtTTGCA5egrHcO3bRWG9OrDWnnzssVc2hWIxRL5h2RQGVQKngzUhPxva4UjL6f8GMqkOJ6lCiOpaojiXyR6Bsllo</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>20520043</pqid></control><display><type>article</type><title>Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol</title><source>Full-Text Journals in Chemistry (Open access)</source><creator>Haji Shabani, A.M. ; Dadfarnia, S. ; Shahbaazi, Z. ; Jafari, A.A.</creator><creatorcontrib>Haji Shabani, A.M. ; Dadfarnia, S. ; Shahbaazi, Z. ; Jafari, A.A.</creatorcontrib><description>An extraction-spectrophotometric method for determination of nickel at sub ppm level using 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the new extractant is described. The reagent reacts with nickel(II) at pH &gt; 10 and form a 1:2 brown complex, which is extracted into chloroform. The complex has a maximum absorption at 421 nm with the molar absorptivity of 2.41 x 10 super(5) M super(-1) cm super(-1). Beer's law is obeyed over the range of 0.011-0.30 mu g mL super(-1). The Sandell's sensitivity for 0.001 absorbance unit is 5.34 x 10 super(-4) mu g cm super(-2). The relative standard deviation at 0.018 mu g mL super(-1) is 1.1% (n = 8). The procedure was successfully applied to determination of nickel in wastewater and standard alloy and the accuracy was determined by recovery experiment, independent analysis by furnace-AAS, and analysis of a certified reference martial.</description><identifier>ISSN: 1011-3924</identifier><identifier>EISSN: 1011-3924</identifier><identifier>EISSN: 1726-801X</identifier><identifier>DOI: 10.4314/bcse.v22i3.61196</identifier><language>eng</language><publisher>Chemical Society of Ethiopia</publisher><subject>Liquid-liquid extraction ; Ni determination ; Schiff bases ; Spectrophotometry</subject><ispartof>Bulletin of the Chemical Society of Ethiopia, 2008-12, Vol.22 (3), p.323-329</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c340t-366a7d542e3db3bf9f02de27e14e1f2275fdbe9ef61b49ee190c355f4b06b73b3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Haji Shabani, A.M.</creatorcontrib><creatorcontrib>Dadfarnia, S.</creatorcontrib><creatorcontrib>Shahbaazi, Z.</creatorcontrib><creatorcontrib>Jafari, A.A.</creatorcontrib><title>Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol</title><title>Bulletin of the Chemical Society of Ethiopia</title><description>An extraction-spectrophotometric method for determination of nickel at sub ppm level using 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the new extractant is described. The reagent reacts with nickel(II) at pH &gt; 10 and form a 1:2 brown complex, which is extracted into chloroform. The complex has a maximum absorption at 421 nm with the molar absorptivity of 2.41 x 10 super(5) M super(-1) cm super(-1). Beer's law is obeyed over the range of 0.011-0.30 mu g mL super(-1). The Sandell's sensitivity for 0.001 absorbance unit is 5.34 x 10 super(-4) mu g cm super(-2). The relative standard deviation at 0.018 mu g mL super(-1) is 1.1% (n = 8). The procedure was successfully applied to determination of nickel in wastewater and standard alloy and the accuracy was determined by recovery experiment, independent analysis by furnace-AAS, and analysis of a certified reference martial.</description><subject>Liquid-liquid extraction</subject><subject>Ni determination</subject><subject>Schiff bases</subject><subject>Spectrophotometry</subject><issn>1011-3924</issn><issn>1011-3924</issn><issn>1726-801X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNpNkc1uFDEQhEcIJELgztEnBIdZ7LY9kzmiKJBIkbjACSHLP-2Ng2c82N7AvgTPHO8uQpy6u1T6SurquteMbgRn4r2xBTcPAIFvBsam4Ul3xihjPZ9APP1vf969KOWeUqB8lGfdn6vfNWtbQ1r6sqKtOa13qaYZaw6WOKyY57Dog4EkT5Zgf2AkupI52Jy2Wc8k4kOTwkJ-6eYmenFtKxVP566EZUug__YW-hmz1WttEbjsY2jg9K4l3e3j94OU4svumdex4Ku_87z7-vHqy-V1f_v5083lh9veckFrz4dBj04KQO4MN37yFBzCiEwg8wCj9M7ghH5gRkyIbKKWS-mFoYMZueHn3c2J65K-V2sOs857lXRQRyHlrdK5BhtRjV5fGI8OqAchtTTGCA5egrHcO3bRWG9OrDWnnzssVc2hWIxRL5h2RQGVQKngzUhPxva4UjL6f8GMqkOJ6lCiOpaojiXyR6Bsllo</recordid><startdate>20081201</startdate><enddate>20081201</enddate><creator>Haji Shabani, A.M.</creator><creator>Dadfarnia, S.</creator><creator>Shahbaazi, Z.</creator><creator>Jafari, A.A.</creator><general>Chemical Society of Ethiopia</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TV</scope><scope>7UA</scope><scope>C1K</scope><scope>DOA</scope></search><sort><creationdate>20081201</creationdate><title>Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol</title><author>Haji Shabani, A.M. ; Dadfarnia, S. ; Shahbaazi, Z. ; Jafari, A.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c340t-366a7d542e3db3bf9f02de27e14e1f2275fdbe9ef61b49ee190c355f4b06b73b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Liquid-liquid extraction</topic><topic>Ni determination</topic><topic>Schiff bases</topic><topic>Spectrophotometry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Haji Shabani, A.M.</creatorcontrib><creatorcontrib>Dadfarnia, S.</creatorcontrib><creatorcontrib>Shahbaazi, Z.</creatorcontrib><creatorcontrib>Jafari, A.A.</creatorcontrib><collection>CrossRef</collection><collection>Pollution Abstracts</collection><collection>Water Resources Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Open Access: DOAJ - Directory of Open Access Journals</collection><jtitle>Bulletin of the Chemical Society of Ethiopia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Haji Shabani, A.M.</au><au>Dadfarnia, S.</au><au>Shahbaazi, Z.</au><au>Jafari, A.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol</atitle><jtitle>Bulletin of the Chemical Society of Ethiopia</jtitle><date>2008-12-01</date><risdate>2008</risdate><volume>22</volume><issue>3</issue><spage>323</spage><epage>329</epage><pages>323-329</pages><issn>1011-3924</issn><eissn>1011-3924</eissn><eissn>1726-801X</eissn><abstract>An extraction-spectrophotometric method for determination of nickel at sub ppm level using 2-[(2-mercaptophenylimino)methyl]phenol (MPMP) as the new extractant is described. The reagent reacts with nickel(II) at pH &gt; 10 and form a 1:2 brown complex, which is extracted into chloroform. The complex has a maximum absorption at 421 nm with the molar absorptivity of 2.41 x 10 super(5) M super(-1) cm super(-1). Beer's law is obeyed over the range of 0.011-0.30 mu g mL super(-1). The Sandell's sensitivity for 0.001 absorbance unit is 5.34 x 10 super(-4) mu g cm super(-2). The relative standard deviation at 0.018 mu g mL super(-1) is 1.1% (n = 8). The procedure was successfully applied to determination of nickel in wastewater and standard alloy and the accuracy was determined by recovery experiment, independent analysis by furnace-AAS, and analysis of a certified reference martial.</abstract><pub>Chemical Society of Ethiopia</pub><doi>10.4314/bcse.v22i3.61196</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1011-3924
ispartof Bulletin of the Chemical Society of Ethiopia, 2008-12, Vol.22 (3), p.323-329
issn 1011-3924
1011-3924
1726-801X
language eng
recordid cdi_doaj_primary_oai_doaj_org_article_7fa8bfed20f245a5bbb432f52bc3fd18
source Full-Text Journals in Chemistry (Open access)
subjects Liquid-liquid extraction
Ni determination
Schiff bases
Spectrophotometry
title Extraction-spectrophotometric determination of nickel at microgram level in water and wastewater using 2-[(2-mercaptophenylimino)methyl]phenol
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T23%3A03%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Extraction-spectrophotometric%20determination%20of%20nickel%20at%20microgram%20level%20in%20water%20and%20wastewater%20using%202-%5B(2-mercaptophenylimino)methyl%5Dphenol&rft.jtitle=Bulletin%20of%20the%20Chemical%20Society%20of%20Ethiopia&rft.au=Haji%20Shabani,%20A.M.&rft.date=2008-12-01&rft.volume=22&rft.issue=3&rft.spage=323&rft.epage=329&rft.pages=323-329&rft.issn=1011-3924&rft.eissn=1011-3924&rft_id=info:doi/10.4314/bcse.v22i3.61196&rft_dat=%3Cproquest_doaj_%3E20520043%3C/proquest_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c340t-366a7d542e3db3bf9f02de27e14e1f2275fdbe9ef61b49ee190c355f4b06b73b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=20520043&rft_id=info:pmid/&rfr_iscdi=true