Loading…

Radiation Dose Calculations for a Hypothetical Accident in Xianning Nuclear Power Plant

Atmospheric dispersion modeling and radiation dose calculations have been performed for a hypothetical AP1000 SGTR accident by HotSpot code 3.03. TEDE, the respiratory time-integrated air concentration, and the ground deposition are calculated for various atmospheric stability classes, Pasquill stab...

Full description

Saved in:
Bibliographic Details
Published in:Science and technology of nuclear installations 2016-01, Vol.2016 (2016), p.1-6
Main Authors: Cao, Bo, Chen, Yixue, Zheng, Junxiao
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Atmospheric dispersion modeling and radiation dose calculations have been performed for a hypothetical AP1000 SGTR accident by HotSpot code 3.03. TEDE, the respiratory time-integrated air concentration, and the ground deposition are calculated for various atmospheric stability classes, Pasquill stability categories A–F with site-specific averaged meteorological conditions. The results indicate that the maximum plume centerline ground deposition value of 1.2E+2 kBq/m2 occurred at about 1.4 km and the maximum TEDE value of 1.41E-05 Sv occurred at 1.4 km from the reactor. It is still far below the annual regulatory limits of 1 mSv for the public as set in IAEA Safety Report Series number 115. The released radionuclides might be transported to long distances but will not have any harmful effect on the public.
ISSN:1687-6075
1687-6083
DOI:10.1155/2016/3105878