Loading…

Comparison of dosimetric analysis of organs at risk and target volumes for ovoids and cylinders in endometrial carcinoma

To compare dose volume parameters of target and organs at risk in vaginal vault brachytherapy using ovoids or cylinder in post-operative endometrial carcinoma. The study was done among 25 histologically proven post-operative endometrial carcinoma patients requiring vaginal brachytherapy. All patient...

Full description

Saved in:
Bibliographic Details
Published in:Journal of contemporary brachytherapy 2023-12, Vol.15 (6), p.414-421
Main Authors: Yashaswini, B R, Pasha, Tanvir, Reddy, B Rekha, Naveen, T, Palled, Siddanna R, Krishna, Uday, Lokesh, V, Sridhar, P, Nikhila, R, Thejaswini, B, Swaroopa, Chundru
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To compare dose volume parameters of target and organs at risk in vaginal vault brachytherapy using ovoids or cylinder in post-operative endometrial carcinoma. The study was done among 25 histologically proven post-operative endometrial carcinoma patients requiring vaginal brachytherapy. All patients underwent both cylinder and ovoids application alternatively on weekly basis. Ovoids size ranged from 2 to 3 cm diameter. Diameters of cylinder ranged between 2.5 and 3.5 cm. Bladder, rectum, urethra, and clinical target volume (CTV) were contoured on CT simulation images. Prescribed dose was 6-7 Gy in 2-3 fractions at 0.5 cm from the surface of applicator. The mean values of D , D , V , V , V , and V of CTV were comparable between cylinder and ovoids plans. The mean dose of CTV was significantly higher with cylinder than with ovoids, and D was significantly higher with ovoids (mean = 15.63 Gy vs. 14.64 Gy, = 0.016, and D = 37.82% vs. 42.86%, = 0.042, for cylinder vs. ovoids). In the dosimetry of the vault, D , D , V , V , V , and mean of the vault did not show any significant difference between cylinder and ovoids. The V was significantly higher with cylinder plans than ovoids, and D of the vault was significantly higher with ovoids plans (V = 14.81% vs. 6.86%, = 0.02, and D = 37.77% vs. 44.80%, = 0.029, for cylinder vs. ovoids). D , D , D , and mean for the bladder, rectum, and urethra were comparable between the cylinder and ovoid plans. The present study showed that the dose to organs at risk, most of the dosimetric parameters of CTV, and vault were comparable between the cylinder and ovoid plans. Both applicators provide good reproducibility. The choice of applicator will ultimately depend on the institutional policies and oncologist decision. However, in patients with dog-ear configuration of the vagina, ovoids may be preferred as per ABS guidelines.
ISSN:1689-832X
2081-2841
DOI:10.5114/jcb.2023.134171